Replaces previous "switch" and "pwm-out" bindings and allows to reference
either gpio or pwm handle and specify maximum current.
Also replacing CONFIG_HAS_LOAD and CONFIG_HAS_USB_PWR with DT_ variants.
The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
Identified issues:
- The load output and USB charging port shared the same state machine,
which did not allow to set different switch-off thresholds.
- Load error codes were global, so it was not possible to have multiple
load instances.
This commit introduces load-specific error_flags, makes the LoadOutput
class inherit from PowerPort (to improve code readability), separates
the load driver better from higher level implementation and adds a
second LoadOutput object for the USB charging port.
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
- Some flags changed to make the firmware compile for new STM32G431 MCU
- Zephyr board definition added
- Serial, OLED display and LED working
- ADC compiling, but not yet working
- Alerts now set to +-20% of actual measured voltage
- Hysteresis for load overvoltage reconnect setpoint made configurable
- Added check for PWM switch MOSFET driver undervoltage
- State machine and control merged to one function
- Load states marked as deprecated, global error flags used instead
- Reduced duplicated code and made load control function easier to read
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
In addition to the normal error flags we now have
ERR_ANY_ERROR which may be used to clear all errors
at once or to use in has_error to see if there is any error flag set.
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
Previous load output expected the battery port as a parameter and checked if
discharging of the battery was allowed. New implementation has own load port
and needs to check if current output (i.e. positive direction) is allowed.
Overvoltage setting is now configured via power port sink_voltage_max.
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.
With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
During tests, the deep discharge counter increased by several 100 counts per day under certain circumstances, most probably because of quite small battery making the voltage toggle between disconnect and reconnect voltage. This commit suggests several improvements.
- Load reconnect voltage increased
- Don't reconnect before waiting at least 1h (lvd_timestamp in load.cpp)
- SOC filter calculation slightly changed to make sure 100% is reached fast enough.
The PWM charge controllers don't have a fuse and need a reliable load short
circuit protection implemented in the microcontroller. The comparator
monitoring the load current now triggers LPTIM connected to the load
disable pin. This allows to switch off the load with a defined time delay
and glitch filter.
During tests, switching off the load in an ISR triggered by COMP2 did
not lead to reliable delays (especially in case of wake-up from sleep),
hence this alternative solution using LPTIM was implemented.
The load switch functions were moved from hardware.cpp to load.cpp.
- Immediate load cut-off in case of current > 2x rated current (still to be fine-tuned)
- Using built-in comparator of STM32 MCU
- Currently only supported by PWM charge controller PCB, as it doesn't have an internal fuse
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory