Load off for internal overtemp implemented

This commit is contained in:
Martin Jaeger
2019-10-31 12:07:21 +01:00
parent b1a7babaff
commit b98461fee4
5 changed files with 55 additions and 8 deletions
+9
View File
@@ -175,6 +175,15 @@ void update_measurements()
uint16_t adcval = (adc_filtered[ADC_POS_TEMP_MCU] >> (4 + ADC_FILTER_CONST)) * vcc / VREFINT_VALUE;
internal_temp = (TSENSE_CAL2_VALUE - TSENSE_CAL1_VALUE) /
(TSENSE_CAL2 - TSENSE_CAL1) * (adcval - TSENSE_CAL1) + TSENSE_CAL1_VALUE;
if (internal_temp > 80) {
log_data.error_flags |= 1U << ERR_INT_OVERTEMP;
}
else if (internal_temp < 70 && (log_data.error_flags & (1U << ERR_INT_OVERTEMP))) {
// remove error flag with hysteresis of 10°C
log_data.error_flags &= ~(1U << ERR_INT_OVERTEMP);
}
// else: keep previous setting
}
#ifndef UNIT_TEST
+21 -2
View File
@@ -275,7 +275,7 @@ void LoadOutput::state_machine()
}
else {
// must be battery over/under temperature then
state = LOAD_STATE_OFF_BAT_TEMP;
state = LOAD_STATE_OFF_TEMPERATURE;
}
}
}
@@ -294,7 +294,7 @@ void LoadOutput::state_machine()
}
else {
// must be battery over/under temperature then
state = LOAD_STATE_OFF_BAT_TEMP;
state = LOAD_STATE_OFF_TEMPERATURE;
}
}
break;
@@ -328,6 +328,13 @@ void LoadOutput::state_machine()
state = LOAD_STATE_DISABLED; // switch to normal mode again
}
break;
case LOAD_STATE_OFF_TEMPERATURE:
if (!(log_data.error_flags & (1U << ERR_INT_OVERTEMP)) &&
port->pos_current_limit > 0)
{
state = LOAD_STATE_DISABLED;
}
break;
}
usb_state_machine();
@@ -363,6 +370,16 @@ void LoadOutput::control()
log_data.error_flags |= (1 << ERR_LOAD_OVERCURRENT);
print_error("Load overcurrent detected\n");
overcurrent_timestamp = time(NULL);
return;
}
// internal overtemperature
if (log_data.error_flags & (1U << ERR_INT_OVERTEMP)) {
switch_set(false);
usb_set(false);
state = LOAD_STATE_OFF_TEMPERATURE;
print_error("Device overtemperature detected\n");
return;
}
// overcurrent detected because of voltage dip by 25%
@@ -374,6 +391,7 @@ void LoadOutput::control()
log_data.error_flags |= (1 << ERR_LOAD_VOLTAGE_DIP);
print_error("Load voltage dip detected\n");
overcurrent_timestamp = time(NULL);
return;
}
voltage_prev = port->voltage;
@@ -389,6 +407,7 @@ void LoadOutput::control()
state = LOAD_STATE_OFF_OVERVOLTAGE;
overcurrent_timestamp = time(NULL);
log_data.error_flags |= (1 << ERR_LOAD_OVERVOLTAGE);
return;
}
}
else {
+1 -1
View File
@@ -40,7 +40,7 @@ enum LoadState {
LOAD_STATE_OFF_OVERCURRENT, ///< Off to protect charge controller (overrules target setting)
LOAD_STATE_OFF_OVERVOLTAGE, ///< Off to protect loads (overrules target setting)
LOAD_STATE_OFF_SHORT_CIRCUIT, ///< Off to protect charge controller (overrules target setting)
LOAD_STATE_OFF_BAT_TEMP ///< Off because of battery over/under-temperature
LOAD_STATE_OFF_TEMPERATURE ///< Off because of battery or charge controller temperature
};
/** Load output type
+2 -1
View File
@@ -43,8 +43,9 @@ enum ErrorFlag {
ERR_LOAD_OVERVOLTAGE, ///< To high voltage for load so that it was switched off
ERR_LOAD_SHORT_CIRCUIT, ///< Short circuit detected by load port
ERR_LOAD_OVERCURRENT, ///< Long-term overcurrent of charge controller
ERR_LOAD_VOLTAGE_DIP ///< Overcurrent identified via voltage dip (may be because of
ERR_LOAD_VOLTAGE_DIP, ///< Overcurrent identified via voltage dip (may be because of
///< too small battery)
ERR_INT_OVERTEMP ///< Charge controller internal temperature too high
};
/** Log Data
+22 -4
View File
@@ -40,13 +40,13 @@ void disabled_to_off_bat_temp_if_error_flag_set()
// overtemp
log_data.error_flags = 1 << ERR_BAT_CHG_OVERTEMP;
load.state_machine();
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_TEMPERATURE, load.state);
// undertemp
load.state = LOAD_STATE_DISABLED;
log_data.error_flags = 1 << ERR_BAT_CHG_UNDERTEMP;
load.state_machine();
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_TEMPERATURE, load.state);
}
void off_low_soc_to_on_after_delay()
@@ -146,12 +146,12 @@ void on_to_off_bat_temp_if_error_flag_set()
load.state = LOAD_STATE_ON;
log_data.error_flags = 1 << ERR_BAT_DIS_OVERTEMP;
load.state_machine();
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_TEMPERATURE, load.state);
load.state = LOAD_STATE_ON;
log_data.error_flags = 1 << ERR_BAT_DIS_UNDERTEMP;
load.state_machine();
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_BAT_TEMP, load.state);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_TEMPERATURE, load.state);
}
void on_to_disabled_if_enable_false()
@@ -225,6 +225,7 @@ void control_off_voltage_dip()
PowerPort port;
LoadOutput load(&port);
port.init_load(14.6);
port.current = 0;
load.voltage_prev = port.voltage;
load.state = LOAD_STATE_ON;
internal_temp = 25;
@@ -241,6 +242,22 @@ void control_off_voltage_dip()
TEST_ASSERT_EQUAL(1 << ERR_LOAD_VOLTAGE_DIP, log_data.error_flags);
}
void control_off_temperature()
{
PowerPort port;
LoadOutput load(&port);
port.init_load(14.6);
port.current = 0;
load.voltage_prev = port.voltage;
load.state = LOAD_STATE_ON;
internal_temp = 25;
load.junction_temperature = 25;
log_data.error_flags = 1U << ERR_INT_OVERTEMP;
load.control();
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_TEMPERATURE, load.state);
}
void load_tests()
{
UNITY_BEGIN();
@@ -261,6 +278,7 @@ void load_tests()
RUN_TEST(control_off_overvoltage);
RUN_TEST(control_off_overcurrent);
RUN_TEST(control_off_voltage_dip);
RUN_TEST(control_off_temperature);
// ToDo: What to do if port current is above the limit, but the hardware can still handle it?