Load overcurrent model now using internal temperature

This commit is contained in:
Martin Jaeger
2019-10-31 11:33:18 +01:00
parent b0e265f3e9
commit b1a7babaff
2 changed files with 10 additions and 1 deletions
+2 -1
View File
@@ -349,7 +349,8 @@ void LoadOutput::control()
junction_temperature = junction_temperature + (
internal_temp - junction_temperature +
port->current * port->current /
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) * (MOSFET_MAX_JUNCTION_TEMP - 25)
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) *
(MOSFET_MAX_JUNCTION_TEMP - INTERNAL_MAX_REFERENCE_TEMP)
) / (MOSFET_THERMAL_TIME_CONSTANT * CONTROL_FREQUENCY);
if (junction_temperature > MOSFET_MAX_JUNCTION_TEMP
+8
View File
@@ -41,6 +41,14 @@
*/
#define MOSFET_MAX_JUNCTION_TEMP 120
/** Internal reference temperature at full load (°C)
*
* This value is used for model-based control of overcurrent protection. It represents
* the steady-state internal temperature for max. continuous current at ambient
* temperature of 25°C.
*/
#define INTERNAL_MAX_REFERENCE_TEMP 50
/** Thermal time constant junction to ambient (s)
*
* This value is used for model-based control of overcurrent protection. It does not reflect