DC/DC and PWM switch configuration via DTS
As these settings are clearly hardware-specific, configuration was moved from Kconfig (hidden symbols) to DTS. New bindings added.
This commit is contained in:
@@ -14,30 +14,6 @@ config HARDWARE_VERSION
|
||||
help
|
||||
Version of the PCB
|
||||
|
||||
config HAS_DCDC_CONVERTER
|
||||
bool
|
||||
help
|
||||
Board has a DC/DC converter.
|
||||
|
||||
config DCDC_PWM_FREQUENCY_KHZ
|
||||
depends on HAS_DCDC_CONVERTER
|
||||
int
|
||||
range 30 100
|
||||
help
|
||||
PWM frequency of DC/DC converter in kHz, range 30 to 100.
|
||||
|
||||
config DCDC_PWM_DEADTIME_NS
|
||||
depends on HAS_DCDC_CONVERTER
|
||||
int
|
||||
range 100 300
|
||||
help
|
||||
Dead time for synchronous PWM generation in nanoseconds.
|
||||
|
||||
config HAS_PWM_SWITCH
|
||||
bool
|
||||
help
|
||||
PCB has PWM power switch.
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
bool
|
||||
help
|
||||
@@ -53,16 +29,6 @@ config NUM_LED_PINS
|
||||
help
|
||||
Number of LED pins for charlieplexing.
|
||||
|
||||
config LOW_SIDE_VOLTAGE_MAX
|
||||
int
|
||||
help
|
||||
Low side (usually battery) voltage maximum.
|
||||
|
||||
config HIGH_SIDE_VOLTAGE_MAX
|
||||
int
|
||||
help
|
||||
High side (usually solar panel) voltage maximum.
|
||||
|
||||
config CONTROL_FREQUENCY
|
||||
int
|
||||
default 10
|
||||
|
||||
+2
-2
@@ -7,7 +7,7 @@
|
||||
|
||||
choice
|
||||
prompt "High-voltage terminal"
|
||||
depends on HAS_DCDC_CONVERTER
|
||||
depends on $(dt_compat_enabled,dcdc)
|
||||
help
|
||||
Select the device connected to the high-voltage
|
||||
side terminal of the DC/DC converter.
|
||||
@@ -44,7 +44,7 @@ endchoice
|
||||
|
||||
choice
|
||||
prompt "PWM terminal"
|
||||
depends on HAS_PWM_SWITCH
|
||||
depends on $(dt_compat_enabled,pwm-switch)
|
||||
help
|
||||
Select the device connected to the PWM switch (currently
|
||||
only solar panel possible)
|
||||
|
||||
@@ -6,15 +6,6 @@ if BOARD_MPPT_1210_HUS_0V4
|
||||
config BOARD
|
||||
default "mppt_1210_hus_0v4"
|
||||
|
||||
config HAS_DCDC_CONVERTER
|
||||
default y
|
||||
|
||||
config DCDC_PWM_FREQUENCY_KHZ
|
||||
default 50
|
||||
|
||||
config DCDC_PWM_DEADTIME_NS
|
||||
default 230
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
default y
|
||||
|
||||
|
||||
@@ -7,22 +7,11 @@
|
||||
#ifndef MPPT_1210_HUS_0V4_H
|
||||
#define MPPT_1210_HUS_0V4_H
|
||||
|
||||
#include <zephyr.h>
|
||||
|
||||
#define DEVICE_TYPE "MPPT-1210-HUS"
|
||||
#define HARDWARE_VERSION "v0.4"
|
||||
|
||||
// DC/DC converter settings
|
||||
#define PWM_FREQUENCY 50 // kHz 50 = better for cloud solar to increase efficiency
|
||||
#define PWM_DEADTIME 230 // ns
|
||||
#define PWM_TIM 3 // use TIM3 timer
|
||||
|
||||
#define DCDC_CURRENT_MAX 10 // PCB maximum DCDC output current
|
||||
#define LOAD_CURRENT_MAX 10 // PCB maximum load switch current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 16 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
#define PIN_UEXT_TX PA_2
|
||||
#define PIN_UEXT_RX PA_3
|
||||
#define PIN_UEXT_SCL PB_6
|
||||
|
||||
@@ -11,6 +11,19 @@
|
||||
model = "Libre Solar MPPT 1210 HUS v0.4";
|
||||
compatible = "st,stm32l073";
|
||||
|
||||
charge-controller {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <40>;
|
||||
ls-voltage-max = <16>;
|
||||
};
|
||||
|
||||
dcdc {
|
||||
compatible = "dcdc";
|
||||
pwm-frequency = <50000>;
|
||||
pwm-deadtime = <230>;
|
||||
current-max = <10>;
|
||||
};
|
||||
|
||||
chosen {
|
||||
zephyr,console = &usart1;
|
||||
zephyr,shell-uart = &usart1;
|
||||
|
||||
@@ -6,15 +6,6 @@ if BOARD_MPPT_1210_HUS_0V7
|
||||
config BOARD
|
||||
default "mppt_1210_hus_0v7"
|
||||
|
||||
config HAS_DCDC_CONVERTER
|
||||
default y
|
||||
|
||||
config DCDC_PWM_FREQUENCY_KHZ
|
||||
default 50
|
||||
|
||||
config DCDC_PWM_DEADTIME_NS
|
||||
default 230
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
default y
|
||||
|
||||
|
||||
@@ -7,22 +7,11 @@
|
||||
#ifndef MPPT_1210_HUS_0V7_H
|
||||
#define MPPT_1210_HUS_0V7_H
|
||||
|
||||
#include <zephyr.h>
|
||||
|
||||
#define DEVICE_TYPE "MPPT-1210-HUS"
|
||||
#define HARDWARE_VERSION "v0.7.1"
|
||||
|
||||
// DC/DC converter settings
|
||||
#define PWM_FREQUENCY 50 // kHz 50 = better for cloud solar to increase efficiency
|
||||
#define PWM_DEADTIME 230 // ns
|
||||
#define PWM_TIM 3 // use TIM3 timer
|
||||
|
||||
#define DCDC_CURRENT_MAX 10 // PCB maximum DCDC output current
|
||||
#define LOAD_CURRENT_MAX 10 // PCB maximum load switch current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 16 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
#define PIN_UEXT_TX PA_2
|
||||
#define PIN_UEXT_RX PA_3
|
||||
#define PIN_UEXT_SCL PB_6
|
||||
|
||||
@@ -11,6 +11,19 @@
|
||||
model = "Libre Solar MPPT 1210 HUS v0.7";
|
||||
compatible = "st,stm32l073";
|
||||
|
||||
charge-controller {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <40>;
|
||||
ls-voltage-max = <16>;
|
||||
};
|
||||
|
||||
dcdc {
|
||||
compatible = "dcdc";
|
||||
pwm-frequency = <50000>;
|
||||
pwm-deadtime = <230>;
|
||||
current-max = <10>;
|
||||
};
|
||||
|
||||
chosen {
|
||||
zephyr,console = &usart1;
|
||||
zephyr,shell-uart = &usart1;
|
||||
@@ -53,6 +66,7 @@
|
||||
label = "BOOT0 pin trigger";
|
||||
};
|
||||
};
|
||||
|
||||
aliases {
|
||||
uart-dbg = &usart1;
|
||||
uext-uart = &usart2;
|
||||
|
||||
@@ -6,21 +6,9 @@ if BOARD_MPPT_2420_HPX
|
||||
config BOARD
|
||||
default "mppt_2420_hpx"
|
||||
|
||||
config HAS_DCDC_CONVERTER
|
||||
default y
|
||||
|
||||
config DCDC_PWM_FREQUENCY_KHZ
|
||||
default 70
|
||||
|
||||
config DCDC_PWM_DEADTIME_NS
|
||||
default 300
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
default y
|
||||
|
||||
config HAS_PWM_SWITCH
|
||||
default y
|
||||
|
||||
config NUM_LED_PINS
|
||||
default 1
|
||||
|
||||
|
||||
@@ -12,17 +12,7 @@
|
||||
#define DEVICE_TYPE "MPPT-2420-HPX"
|
||||
#define HARDWARE_VERSION "v0.1"
|
||||
|
||||
// DC/DC converter settings
|
||||
#define PWM_FREQUENCY 70 // kHz
|
||||
#define PWM_DEADTIME 300 // ns
|
||||
#define PWM_TIM 1 // use TIM1 timer
|
||||
|
||||
#define DCDC_CURRENT_MAX 20 // PCB maximum DCDC output current
|
||||
#define LOAD_CURRENT_MAX 20 // PCB maximum load switch current
|
||||
#define PWM_CURRENT_MAX 20 // PCB maximum PWM switch (solar) current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 16 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
#define PIN_UEXT_TX PA_2
|
||||
#define PIN_UEXT_RX PA_3
|
||||
|
||||
@@ -42,6 +42,25 @@
|
||||
};
|
||||
};
|
||||
|
||||
charge-controller {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <80>;
|
||||
ls-voltage-max = <32>;
|
||||
};
|
||||
|
||||
dcdc {
|
||||
compatible = "dcdc";
|
||||
pwm-frequency = <70000>;
|
||||
pwm-deadtime = <300>;
|
||||
current-max = <20>;
|
||||
};
|
||||
|
||||
pwm-switch {
|
||||
compatible = "pwm-switch";
|
||||
pwm-frequency = <50>;
|
||||
current-max = <20>;
|
||||
};
|
||||
|
||||
chosen {
|
||||
zephyr,console = &usart1;
|
||||
zephyr,shell-uart = &usart1;
|
||||
|
||||
@@ -6,15 +6,6 @@ if BOARD_MPPT_2420_LC_0V10
|
||||
config BOARD
|
||||
default "mppt_2420_lc_0v10"
|
||||
|
||||
config HAS_DCDC_CONVERTER
|
||||
default y
|
||||
|
||||
config DCDC_PWM_FREQUENCY_KHZ
|
||||
default 70
|
||||
|
||||
config DCDC_PWM_DEADTIME_NS
|
||||
default 300
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
default y
|
||||
|
||||
|
||||
@@ -10,19 +10,8 @@
|
||||
#define DEVICE_TYPE "MPPT-2420-LC"
|
||||
#define HARDWARE_VERSION "v0.10"
|
||||
|
||||
#include <zephyr.h>
|
||||
|
||||
// DC/DC converter settings
|
||||
#define PWM_FREQUENCY 70 // kHz 70 = good compromise between output ripple and efficiency
|
||||
#define PWM_DEADTIME 300 // ns
|
||||
#define PWM_TIM 1 // use TIM1 timer
|
||||
|
||||
#define DCDC_CURRENT_MAX 20 // PCB maximum DCDC output current
|
||||
#define LOAD_CURRENT_MAX 20 // PCB maximum load switch current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 32 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
#define PIN_UEXT_DIS PC_14 // starting from rev. 0.10
|
||||
#define PIN_UEXT_TX PA_2
|
||||
#define PIN_UEXT_RX PA_3
|
||||
|
||||
@@ -11,6 +11,19 @@
|
||||
model = "Libre Solar MPPT 2420 LC v0.10";
|
||||
compatible = "st,stm32f072";
|
||||
|
||||
charge-controller {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <55>;
|
||||
ls-voltage-max = <32>;
|
||||
};
|
||||
|
||||
dcdc {
|
||||
compatible = "dcdc";
|
||||
pwm-frequency = <70000>;
|
||||
pwm-deadtime = <300>;
|
||||
current-max = <20>;
|
||||
};
|
||||
|
||||
chosen {
|
||||
zephyr,console = &usart1;
|
||||
zephyr,shell-uart = &usart1;
|
||||
|
||||
@@ -6,9 +6,6 @@ if BOARD_PWM_2420_LUS_0V3
|
||||
config BOARD
|
||||
default "pwm_2420_lus_0v3"
|
||||
|
||||
config HAS_PWM_SWITCH
|
||||
default y
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
default y
|
||||
|
||||
|
||||
@@ -7,8 +7,6 @@
|
||||
#ifndef PWM_2420_LUS_H
|
||||
#define PWM_2420_LUS_H
|
||||
|
||||
#include <zephyr.h>
|
||||
|
||||
#define DEVICE_TYPE "PWM-2420-LUS"
|
||||
|
||||
#ifdef CONFIG_BOARD_PWM_2420_LUS_0V2
|
||||
@@ -17,16 +15,8 @@
|
||||
#define HARDWARE_VERSION "v0.3"
|
||||
#endif
|
||||
|
||||
#define PWM_TIM 3 // use TIM3 timer
|
||||
#define PWM_FREQUENCY 50 // Hz
|
||||
|
||||
// Current reduced to 15A. Increase to 20A PCB max values only if attached to a big heat sink.
|
||||
#define PWM_CURRENT_MAX 15 // PCB maximum PWM switch (solar) current
|
||||
#define LOAD_CURRENT_MAX 15 // PCB maximum load switch current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 32 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
// The MCU, where internal temperature is measured, is close to the MOSFETs. Tests showed that
|
||||
// temperature at heat sink is only 10-20°C above measured internal temp. As PWM CC doesn't
|
||||
// use electrolytic cap for core charging function, internal temperature of 70°C can be allowed.
|
||||
|
||||
@@ -11,6 +11,20 @@
|
||||
model = "Libre Solar PWM 2420 LUS v0.3";
|
||||
compatible = "st,stm32l073";
|
||||
|
||||
charge-controller {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <55>;
|
||||
ls-voltage-max = <32>;
|
||||
};
|
||||
|
||||
pwm-switch {
|
||||
compatible = "pwm-switch";
|
||||
pwm-frequency = <50>;
|
||||
// Current reduced to 15A. Increase to 20A PCB max values
|
||||
// only if attached to a big heat sink.
|
||||
current-max = <15>;
|
||||
};
|
||||
|
||||
chosen {
|
||||
zephyr,console = &usart1;
|
||||
zephyr,shell-uart = &usart1;
|
||||
|
||||
+16
-12
@@ -6,6 +6,10 @@
|
||||
|
||||
#include "daq.h"
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include <math.h> // log for thermistor calculation
|
||||
#include <assert.h>
|
||||
|
||||
@@ -14,10 +18,10 @@
|
||||
#include "debug.h"
|
||||
#include "board.h" // contains defines for pins
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
static float dcdc_current_offset;
|
||||
#endif
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
static float pwm_current_offset;
|
||||
#endif
|
||||
static float load_current_offset;
|
||||
@@ -88,10 +92,10 @@ static inline float ntc_temp(uint32_t channel, int32_t vref)
|
||||
void calibrate_current_sensors()
|
||||
{
|
||||
int vref = VREF;
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
dcdc_current_offset = -adc_scaled(ADC_POS_I_DCDC, vref, ADC_GAIN_I_DCDC);
|
||||
#endif
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
pwm_current_offset = -adc_scaled(ADC_POS_I_PWM, vref, ADC_GAIN_I_PWM);
|
||||
#endif
|
||||
load_current_offset = -adc_scaled(ADC_POS_I_LOAD, vref, ADC_GAIN_I_LOAD);
|
||||
@@ -103,7 +107,7 @@ void adc_update_value(unsigned int pos)
|
||||
// y(n) = c * x(n) + (c - 1) * y(n-1)
|
||||
// see also here: http://techteach.no/simview/lowpass_filter/doc/filter_algorithm.pdf
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH == 1
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
if (pos == ADC_POS_V_PWM || pos == ADC_POS_I_PWM) {
|
||||
// only read input voltage and current when switch is on or permanently off
|
||||
if (pwm_switch.signal_high() || pwm_switch.active() == false) {
|
||||
@@ -154,18 +158,18 @@ void daq_update()
|
||||
// calculate lower voltage first, as it is needed for PWM terminal voltage calculation
|
||||
lv_bus.voltage = adc_scaled(ADC_POS_V_LOW, vref, ADC_GAIN_V_LOW);
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
hv_bus.voltage = adc_scaled(ADC_POS_V_HIGH, vref, ADC_GAIN_V_HIGH);
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
pwm_switch.ext_voltage = lv_bus.voltage - vref * (ADC_OFFSET_V_PWM / 1000.0) -
|
||||
adc_scaled(ADC_POS_V_PWM, vref, ADC_GAIN_V_PWM);
|
||||
#endif
|
||||
|
||||
load.current = adc_scaled(ADC_POS_I_LOAD, vref, ADC_GAIN_I_LOAD) + load_current_offset;
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
// current multiplied with PWM duty cycle for PWM charger to get avg current for correct power
|
||||
// calculation
|
||||
pwm_switch.current = -pwm_switch.get_duty_cycle() * (
|
||||
@@ -176,7 +180,7 @@ void daq_update()
|
||||
pwm_switch.power = pwm_switch.bus->voltage * pwm_switch.current;
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
dcdc_lv_port.current =
|
||||
adc_scaled(ADC_POS_I_DCDC, vref, ADC_GAIN_I_DCDC) + dcdc_current_offset;
|
||||
|
||||
@@ -206,7 +210,7 @@ void daq_update()
|
||||
}
|
||||
#endif
|
||||
|
||||
#ifdef PIN_ADC_TEMP_FETS
|
||||
#if DT_COMPAT_DCDC && defined(PIN_ADC_TEMP_FETS)
|
||||
// MOSFET temperature calculation
|
||||
dcdc.temp_mosfets = ntc_temp(ADC_POS_TEMP_FETS, vref);
|
||||
#endif
|
||||
@@ -229,10 +233,10 @@ void daq_update()
|
||||
void high_voltage_alert()
|
||||
{
|
||||
// disable any sort of input
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
dcdc.emergency_stop();
|
||||
#endif
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
pwm_switch.emergency_stop();
|
||||
#endif
|
||||
// do not use enter_state function, as we don't want to wait entire recharge delay
|
||||
|
||||
@@ -4,6 +4,10 @@
|
||||
* SPDX-License-Identifier: Apache-2.0
|
||||
*/
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include <stdio.h>
|
||||
|
||||
#include "setup.h"
|
||||
@@ -190,12 +194,12 @@ const data_object_t data_objects[] = {
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
TS_DATA_OBJ_BOOL(0x62, "DcdcEn", &dcdc.enable,
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
TS_DATA_OBJ_BOOL(0x63, "PwmEn", &pwm_switch.enable,
|
||||
TS_INPUT, TS_READ_ALL | TS_WRITE_ALL),
|
||||
#endif
|
||||
@@ -247,7 +251,7 @@ const data_object_t data_objects[] = {
|
||||
TS_DATA_OBJ_FLOAT(0x76, "Int_degC", &dev_stat.internal_temp, 1,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
#if defined(PIN_ADC_TEMP_FETS) && CONFIG_HAS_DCDC_CONVERTER
|
||||
#if defined(PIN_ADC_TEMP_FETS) && DT_COMPAT_DCDC
|
||||
TS_DATA_OBJ_FLOAT(0x77, "Mosfet_degC", &dcdc.temp_mosfets, 1,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
#endif
|
||||
@@ -255,7 +259,7 @@ const data_object_t data_objects[] = {
|
||||
TS_DATA_OBJ_UINT32(0x78, "ChgState", &charger.state,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
TS_DATA_OBJ_UINT16(0x79, "DCDCState", &dcdc.state,
|
||||
TS_OUTPUT, TS_READ_ALL),
|
||||
#endif
|
||||
@@ -378,7 +382,7 @@ const data_object_t data_objects[] = {
|
||||
// CALIBRATION DATA ///////////////////////////////////////////////////////
|
||||
// using IDs >= 0xD0
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
TS_DATA_OBJ_FLOAT(0xD0, "DcdcMin_W", &dcdc.output_power_min, 1,
|
||||
TS_CAL, TS_READ_ALL | TS_WRITE_MAKER),
|
||||
|
||||
|
||||
+13
-8
@@ -6,6 +6,10 @@
|
||||
|
||||
#include "dcdc.h"
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include <math.h> // for fabs function
|
||||
#include <stdlib.h> // for min/max function
|
||||
#include <stdio.h>
|
||||
@@ -19,7 +23,7 @@
|
||||
|
||||
extern DeviceStatus dev_stat;
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER == 0
|
||||
#if !DT_COMPAT_DCDC
|
||||
|
||||
Dcdc::Dcdc(PowerPort *hv_side, PowerPort *lv_side, DcdcOperationMode op_mode) {}
|
||||
|
||||
@@ -32,11 +36,11 @@ Dcdc::Dcdc(PowerPort *hv_side, PowerPort *lv_side, DcdcOperationMode op_mode)
|
||||
mode = op_mode;
|
||||
enable = true;
|
||||
state = DCDC_STATE_OFF;
|
||||
lvs->neg_current_limit = -DCDC_CURRENT_MAX;
|
||||
lvs->pos_current_limit = DCDC_CURRENT_MAX;
|
||||
ls_current_max = DCDC_CURRENT_MAX;
|
||||
hs_voltage_max = HIGH_SIDE_VOLTAGE_MAX;
|
||||
ls_voltage_max = LOW_SIDE_VOLTAGE_MAX;
|
||||
lvs->neg_current_limit = -DT_INST_0_DCDC_CURRENT_MAX;
|
||||
lvs->pos_current_limit = DT_INST_0_DCDC_CURRENT_MAX;
|
||||
ls_current_max = DT_INST_0_DCDC_CURRENT_MAX;
|
||||
hs_voltage_max = DT_INST_0_CHARGE_CONTROLLER_HS_VOLTAGE_MAX;
|
||||
ls_voltage_max = DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX;
|
||||
ls_voltage_min = 9.0;
|
||||
output_power_min = 1; // switch off if power < 1 W
|
||||
restart_interval = 60;
|
||||
@@ -44,7 +48,8 @@ Dcdc::Dcdc(PowerPort *hv_side, PowerPort *lv_side, DcdcOperationMode op_mode)
|
||||
pwm_delta = 1; // start-condition of duty cycle pwr_inc_pwm_direction
|
||||
|
||||
// lower duty limit might have to be adjusted dynamically depending on LS voltage
|
||||
half_bridge_init(PWM_FREQUENCY, PWM_DEADTIME, 12 / hs_voltage_max, 0.97);
|
||||
half_bridge_init(DT_INST_0_DCDC_PWM_FREQUENCY / 1000, DT_INST_0_DCDC_PWM_DEADTIME,
|
||||
12 / hs_voltage_max, 0.97);
|
||||
}
|
||||
|
||||
int Dcdc::duty_cycle_delta()
|
||||
@@ -283,4 +288,4 @@ void Dcdc::fuse_destruction()
|
||||
counter++;
|
||||
}
|
||||
|
||||
#endif /* CONFIG_HAS_DCDC_CONVERTER */
|
||||
#endif /* DT_COMPAT_DCDC */
|
||||
|
||||
@@ -84,7 +84,7 @@ void DeviceStatus::update_min_max_values()
|
||||
}
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
if (dcdc.lvs->current > dcdc_current_max) {
|
||||
dcdc_current_max = dcdc.lvs->current;
|
||||
}
|
||||
|
||||
+2
-2
@@ -253,9 +253,9 @@ uint32_t PWM_UT::m_ccr = 0;
|
||||
|
||||
#endif /* UNIT_TEST */
|
||||
|
||||
#if (PWM_TIM == 1)
|
||||
#if defined(STM32F0) || defined(STM32G4)
|
||||
typedef PWM_TIM1 PWM_TIM_HW;
|
||||
#elif (PWM_TIM == 3)
|
||||
#elif defined(STM32L0)
|
||||
typedef PWM_TIM3 PWM_TIM_HW;
|
||||
#else
|
||||
typedef PWM_UT PWM_TIM_HW;
|
||||
|
||||
+13
-4
@@ -6,6 +6,10 @@
|
||||
|
||||
#include "load.h"
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include "board.h"
|
||||
#include "leds.h"
|
||||
#include "device_status.h"
|
||||
@@ -45,7 +49,9 @@ void LoadOutput::control()
|
||||
(CONFIG_MOSFET_MAX_JUNCTION_TEMP - CONFIG_INTERNAL_MAX_REFERENCE_TEMP)
|
||||
) / (CONFIG_MOSFET_THERMAL_TIME_CONSTANT * CONFIG_CONTROL_FREQUENCY);
|
||||
|
||||
if (junction_temperature > CONFIG_MOSFET_MAX_JUNCTION_TEMP || current > LOAD_CURRENT_MAX * 2) {
|
||||
if (junction_temperature > CONFIG_MOSFET_MAX_JUNCTION_TEMP ||
|
||||
current > LOAD_CURRENT_MAX * 2)
|
||||
{
|
||||
flags_set(&error_flags, ERR_LOAD_OVERCURRENT);
|
||||
oc_timestamp = uptime();
|
||||
}
|
||||
@@ -62,9 +68,12 @@ void LoadOutput::control()
|
||||
|
||||
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
|
||||
// off the solar input instead of the load output)
|
||||
if (bus->voltage > overvoltage || bus->voltage > LOW_SIDE_VOLTAGE_MAX) {
|
||||
if (bus->voltage > overvoltage || bus->voltage >
|
||||
DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX)
|
||||
{
|
||||
ov_debounce_counter++;
|
||||
if (ov_debounce_counter > CONFIG_CONTROL_FREQUENCY) { // waited 1s before setting the flag
|
||||
if (ov_debounce_counter > CONFIG_CONTROL_FREQUENCY) {
|
||||
// waited 1s before setting the flag
|
||||
flags_set(&error_flags, ERR_LOAD_OVERVOLTAGE);
|
||||
}
|
||||
}
|
||||
@@ -99,7 +108,7 @@ void LoadOutput::control()
|
||||
|
||||
if (flags_check(&error_flags, ERR_LOAD_OVERVOLTAGE) &&
|
||||
bus->voltage < (overvoltage - ov_hysteresis) &&
|
||||
bus->voltage < (LOW_SIDE_VOLTAGE_MAX - ov_hysteresis))
|
||||
bus->voltage < (DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
flags_clear(&error_flags, ERR_LOAD_OVERVOLTAGE);
|
||||
}
|
||||
|
||||
+5
-5
@@ -99,12 +99,12 @@ void control_thread()
|
||||
|
||||
lv_terminal.update_bus_current_margins();
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
//pwm_switch.control();
|
||||
leds_set_charging(pwm_switch.active());
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
hv_terminal.update_bus_current_margins();
|
||||
dcdc.control(); // control of DC/DC including MPPT algorithm
|
||||
leds_set_charging(half_bridge_enabled());
|
||||
@@ -123,11 +123,11 @@ void control_thread()
|
||||
last_call = now;
|
||||
|
||||
// energy + soc calculation must be called exactly once per second
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
hv_terminal.energy_balance();
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
pwm_switch.energy_balance();
|
||||
#endif
|
||||
|
||||
@@ -137,7 +137,7 @@ void control_thread()
|
||||
dev_stat.update_min_max_values();
|
||||
charger.update_soc(&bat_conf);
|
||||
|
||||
#if CONFIG_HS_MOSFET_FAIL_SAFE_PROTECTION && CONFIG_HAS_DCDC_CONVERTER
|
||||
#if CONFIG_HS_MOSFET_FAIL_SAFE_PROTECTION && DT_COMPAT_DCDC
|
||||
if (dev_stat.has_error(ERR_DCDC_HS_MOSFET_SHORT)) {
|
||||
dcdc.fuse_destruction();
|
||||
}
|
||||
|
||||
+9
-5
@@ -6,6 +6,10 @@
|
||||
|
||||
#include "pwm_switch.h"
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include <stdio.h>
|
||||
#include <time.h>
|
||||
|
||||
@@ -14,7 +18,7 @@
|
||||
#include "debug.h"
|
||||
#include "helper.h"
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
|
||||
static bool _pwm_active;
|
||||
|
||||
@@ -160,7 +164,7 @@ PwmSwitch::PwmSwitch(DcBus *dc_bus) :
|
||||
offset_voltage_start = 2.0; // V charging switched on if Vsolar > Vbat + offset
|
||||
restart_interval = 60; // s When should we retry to start charging after low solar power cut-off?
|
||||
|
||||
pwm_signal_init_registers(PWM_FREQUENCY);
|
||||
pwm_signal_init_registers(DT_INST_0_PWM_SWITCH_PWM_FREQUENCY);
|
||||
|
||||
enable = true; // enable charging in general
|
||||
_pwm_active = false; // still disable actual switch
|
||||
@@ -179,8 +183,8 @@ void PwmSwitch::control()
|
||||
print_info("PWM charger stop.\n");
|
||||
}
|
||||
else if (bus->voltage > bus->sink_control_voltage() // bus voltage above target
|
||||
|| current < neg_current_limit // port current limit exceeded
|
||||
|| current < -PWM_CURRENT_MAX) // PCB current limit exceeded
|
||||
|| current < neg_current_limit // port current limit exceeded
|
||||
|| current < -DT_INST_0_PWM_SWITCH_CURRENT_MAX) // PCB current limit exceeded
|
||||
{
|
||||
// decrease power, as limits were reached
|
||||
|
||||
@@ -238,4 +242,4 @@ float PwmSwitch::get_duty_cycle()
|
||||
return pwm_signal_get_duty_cycle();
|
||||
}
|
||||
|
||||
#endif /* CONFIG_HAS_PWM_SWITCH */
|
||||
#endif /* DT_COMPAT_PWM_SWITCH */
|
||||
|
||||
+6
-2
@@ -9,6 +9,10 @@
|
||||
* @brief Setup of ports and other essential charge controller objects
|
||||
*/
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include "thingset.h" // handles access to internal data via communication interfaces
|
||||
#include "board.h" // hardware-specific settings
|
||||
|
||||
@@ -28,7 +32,7 @@
|
||||
DcBus lv_bus;
|
||||
PowerPort lv_terminal(&lv_bus, true); // low voltage terminal (battery for typical MPPT)
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
DcBus hv_bus;
|
||||
PowerPort hv_terminal(&hv_bus, true); // high voltage terminal (solar for typical MPPT)
|
||||
PowerPort dcdc_lv_port(&lv_bus); // internal low voltage side of DC/DC converter
|
||||
@@ -41,7 +45,7 @@ Dcdc dcdc(&hv_terminal, &dcdc_lv_port, MODE_MPPT_BUCK);
|
||||
#endif // CONFIG_HV_TERMINAL
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
PwmSwitch pwm_switch(&lv_bus);
|
||||
#endif
|
||||
|
||||
|
||||
+6
-2
@@ -4,6 +4,10 @@
|
||||
* SPDX-License-Identifier: Apache-2.0
|
||||
*/
|
||||
|
||||
#ifndef UNIT_TEST
|
||||
#include <zephyr.h>
|
||||
#endif
|
||||
|
||||
#include <stdio.h>
|
||||
|
||||
#include "bat_charger.h"
|
||||
@@ -17,14 +21,14 @@
|
||||
extern DcBus lv_bus;
|
||||
extern PowerPort lv_terminal;
|
||||
|
||||
#if CONFIG_HAS_DCDC_CONVERTER
|
||||
#if DT_COMPAT_DCDC
|
||||
extern DcBus hv_bus;
|
||||
extern PowerPort hv_terminal;
|
||||
extern PowerPort dcdc_lv_port;
|
||||
extern Dcdc dcdc;
|
||||
#endif
|
||||
|
||||
#if CONFIG_HAS_PWM_SWITCH
|
||||
#if DT_COMPAT_PWM_SWITCH
|
||||
extern PwmSwitch pwm_switch;
|
||||
#endif
|
||||
|
||||
|
||||
+13
-11
@@ -8,10 +8,10 @@
|
||||
#define PCB_STUB_H
|
||||
|
||||
// PWM charge controller
|
||||
#define CONFIG_PWM_TERMINAL_SOLAR CONFIG_HAS_PWM_SWITCH
|
||||
#define CONFIG_PWM_TERMINAL_SOLAR DT_COMPAT_PWM_SWITCH
|
||||
|
||||
// MPPT buck/boost or nanogrid mode
|
||||
#define CONFIG_HV_TERMINAL_SOLAR CONFIG_HAS_DCDC_CONVERTER
|
||||
#define CONFIG_HV_TERMINAL_SOLAR DT_COMPAT_DCDC
|
||||
#define CONFIG_HV_TERMINAL_NANOGRID 0
|
||||
|
||||
// battery always assumed to be at low-voltage terminal (might need to be changed for boost mode)
|
||||
@@ -28,8 +28,15 @@
|
||||
#define HARDWARE_VERSION "v0.1"
|
||||
|
||||
// specify features of charge controller
|
||||
#define CONFIG_HAS_DCDC_CONVERTER 1
|
||||
#define CONFIG_HAS_PWM_SWITCH 1
|
||||
#define DT_COMPAT_DCDC 1
|
||||
#define DT_INST_0_DCDC_PWM_FREQUENCY 70000 // Hz
|
||||
#define DT_INST_0_DCDC_PWM_DEADTIME 300 // ns
|
||||
#define DT_INST_0_DCDC_CURRENT_MAX 20 // A
|
||||
|
||||
#define DT_COMPAT_PWM_SWITCH 1
|
||||
#define DT_INST_0_PWM_SWITCH_PWM_FREQUENCY 50 // Hz
|
||||
#define DT_INST_0_PWM_SWITCH_CURRENT_MAX 20 // A
|
||||
|
||||
#define CONFIG_HAS_LOAD_OUTPUT 1
|
||||
#define CONFIG_HAS_USB_PWR_OUTPUT 1
|
||||
|
||||
@@ -39,15 +46,10 @@
|
||||
#define CONFIG_INTERNAL_MAX_REFERENCE_TEMP 50
|
||||
#define CONFIG_MOSFET_THERMAL_TIME_CONSTANT 5
|
||||
|
||||
#define PWM_FREQUENCY 50 // kHz
|
||||
#define PWM_DEADTIME 230 // ns
|
||||
|
||||
#define PWM_CURRENT_MAX 15 // PCB maximum PWM switch (solar) current
|
||||
#define DCDC_CURRENT_MAX 20 // PCB maximum DCDC output current
|
||||
#define LOAD_CURRENT_MAX 20 // PCB maximum load switch current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 32 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
#define DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX 32 // Maximum voltage at battery port (V)
|
||||
#define DT_INST_0_CHARGE_CONTROLLER_HS_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
#define PIN_UEXT_TX 0
|
||||
#define PIN_UEXT_RX 0
|
||||
|
||||
@@ -0,0 +1,16 @@
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# Copyright (c) 2020 Martin Jäger / Libre Solar
|
||||
|
||||
description: Generic charge controller device setup
|
||||
|
||||
compatible: "charge-controller"
|
||||
|
||||
properties:
|
||||
hs-voltage-max:
|
||||
type: int
|
||||
required: true
|
||||
description: Maximum voltage at high-side (typically PV input) in volts
|
||||
ls-voltage-max:
|
||||
type: int
|
||||
required: true
|
||||
description: Maximum voltage at low-side (typically battery) in volts
|
||||
@@ -0,0 +1,20 @@
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# Copyright (c) 2020 Martin Jäger / Libre Solar
|
||||
|
||||
description: DC/DC converter as part of MPPT charge controllers
|
||||
|
||||
compatible: "dcdc"
|
||||
|
||||
properties:
|
||||
pwm-frequency:
|
||||
type: int
|
||||
required: true
|
||||
description: PWM frequency in Hz
|
||||
pwm-deadtime:
|
||||
type: int
|
||||
required: true
|
||||
description: Dead time for synchronous PWM generation in nanoseconds
|
||||
current-max:
|
||||
type: int
|
||||
required: true
|
||||
description: Maximum inductor current in amps
|
||||
@@ -0,0 +1,16 @@
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# Copyright (c) 2020 Martin Jäger / Libre Solar
|
||||
|
||||
description: MOSFETs of PWM charge controllers
|
||||
|
||||
compatible: "pwm-switch"
|
||||
|
||||
properties:
|
||||
pwm-frequency:
|
||||
type: int
|
||||
required: true
|
||||
description: PWM frequency in Hz
|
||||
current-max:
|
||||
type: int
|
||||
required: true
|
||||
description: Maximum inductor current in amps
|
||||