Move thermal model parameters to DTS
This commit is contained in:
+164
-3
@@ -1,9 +1,170 @@
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# Copyright (c) 2019 Martin Jäger (Libre Solar)
|
||||
|
||||
#
|
||||
# Generic Libre Solar Charge Controller configuration
|
||||
# Invisible (board-specific) Kconfig symbols
|
||||
#
|
||||
|
||||
rsource "Kconfig.hidden"
|
||||
config HAS_LOAD_OUTPUT
|
||||
bool
|
||||
help
|
||||
PCB has a load output.
|
||||
|
||||
rsource "Kconfig.user"
|
||||
config HAS_USB_PWR_OUTPUT
|
||||
bool
|
||||
help
|
||||
PCB has a USB power output.
|
||||
|
||||
config CONTROL_FREQUENCY
|
||||
int
|
||||
default 10
|
||||
help
|
||||
Main control function frequency (Hz)
|
||||
|
||||
Frequencies higher than 10 Hz caused issues with MPPT control during lab test with
|
||||
PV simulator. Might be different with actual solar panel.
|
||||
|
||||
|
||||
#
|
||||
# Visible (user-configurable) Kconfig symbols
|
||||
#
|
||||
|
||||
choice
|
||||
prompt "High-voltage terminal"
|
||||
depends on $(dt_compat_enabled,dcdc)
|
||||
help
|
||||
Select the device connected to the high-voltage
|
||||
side terminal of the DC/DC converter.
|
||||
|
||||
config HV_TERMINAL_SOLAR
|
||||
bool "Solar panel"
|
||||
|
||||
config HV_TERMINAL_NANOGRID
|
||||
bool "DC nanogrid"
|
||||
|
||||
config HV_TERMINAL_GENERATOR
|
||||
bool "DC generator, e.g. wind turbine"
|
||||
|
||||
config HV_TERMINAL_BATTERY
|
||||
bool "Battery, e.g. electric bicycle"
|
||||
endchoice
|
||||
|
||||
|
||||
choice
|
||||
prompt "Low-voltage terminal"
|
||||
help
|
||||
Select the device connected to the low-voltage side
|
||||
of the charge controller (usually battery terminal).
|
||||
|
||||
config LV_TERMINAL_BATTERY
|
||||
depends on !HV_TERMINAL_BATTERY
|
||||
bool "Battery 12V/24V"
|
||||
|
||||
config LV_TERMINAL_SOLAR
|
||||
depends on HV_TERMINAL_BATTERY || HV_TERMINAL_NANOGRID
|
||||
bool "Solar panel"
|
||||
endchoice
|
||||
|
||||
|
||||
choice
|
||||
prompt "PWM terminal"
|
||||
depends on $(dt_compat_enabled,pwm-switch)
|
||||
help
|
||||
Select the device connected to the PWM switch (currently
|
||||
only solar panel possible)
|
||||
|
||||
config PWM_TERMINAL_SOLAR
|
||||
depends on LV_TERMINAL_BATTERY && !HV_TERMINAL_SOLAR
|
||||
bool "Solar panel"
|
||||
endchoice
|
||||
|
||||
|
||||
menu "Battery configuration"
|
||||
|
||||
choice
|
||||
prompt "Default battery cell type"
|
||||
default BAT_DEFAULT_TYPE_GEL
|
||||
help
|
||||
Select the type of the single cells inside the battery
|
||||
to determine voltage set points. Total voltage set points
|
||||
are multiplied with the selected number of cells.
|
||||
|
||||
config BAT_DEFAULT_TYPE_FLOODED
|
||||
bool "Flooded (wet) lead-acid"
|
||||
|
||||
config BAT_DEFAULT_TYPE_GEL
|
||||
bool "VRLA gel, maintainance-free"
|
||||
|
||||
config BAT_DEFAULT_TYPE_AGM
|
||||
bool "AGM, maintainance-free"
|
||||
|
||||
config BAT_DEFAULT_TYPE_LFP
|
||||
bool "LiFePO4 Li-ion, 3.3V nominal"
|
||||
|
||||
config BAT_DEFAULT_TYPE_NMC
|
||||
bool "NMC/Graphite Li-ion, 3.7V nominal, 4.2V max"
|
||||
|
||||
config BAT_DEFAULT_TYPE_NMC_HV
|
||||
bool "NMC/Graphite High Voltage Li-ion, 3.7V nominal, 4.35 max"
|
||||
|
||||
endchoice
|
||||
|
||||
config BAT_DEFAULT_NUM_CELLS
|
||||
int "Default number of battery cells"
|
||||
default 6
|
||||
range 3 16
|
||||
help
|
||||
Typical choices:
|
||||
- 6 for 12V lead-acid battery
|
||||
- 4 for 12V LiFePO4 battery
|
||||
- 3 for 12V NMC Li-ion battery
|
||||
|
||||
Remarks:
|
||||
- If you choose settings for 12V system, 24V systems
|
||||
(2 batteries in series) are recognized automatically
|
||||
- Make sure the voltage of the used charge controller
|
||||
is not exceeded.
|
||||
|
||||
config BAT_DEFAULT_CAPACITY_AH
|
||||
int "Default battery capacity in Ah"
|
||||
range 10 200
|
||||
default 50
|
||||
|
||||
endmenu
|
||||
|
||||
|
||||
menu "Extensions and interfaces"
|
||||
|
||||
config EXT_OLED_DISPLAY
|
||||
bool "OLED display at UEXT"
|
||||
|
||||
config EXT_OLED_BRIGHTNESS
|
||||
depends on EXT_OLED_DISPLAY
|
||||
int "OLED display brightness"
|
||||
range 1 255
|
||||
default 1
|
||||
|
||||
config EXT_THINGSET_SERIAL
|
||||
bool "ThingSet serial interface"
|
||||
|
||||
config EXT_THINGSET_SERIAL_RX_BUF_SIZE
|
||||
depends on EXT_THINGSET_SERIAL
|
||||
int "ThingSet serial RX buffer size"
|
||||
range 64 2048
|
||||
default 512
|
||||
|
||||
config EXT_THINGSET_SERIAL_TX_BUF_SIZE
|
||||
depends on EXT_THINGSET_SERIAL
|
||||
int "ThingSet serial TX buffer size"
|
||||
range 256 2048
|
||||
default 1024
|
||||
|
||||
config EXT_THINGSET_CAN
|
||||
depends on CAN
|
||||
bool "ThingSet CAN interface"
|
||||
|
||||
config DEVICE_ID
|
||||
int "Initial device ID for communication interfaces"
|
||||
default 0
|
||||
|
||||
endmenu
|
||||
|
||||
@@ -1,67 +0,0 @@
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# Copyright (c) 2019 Martin Jäger (Libre Solar)
|
||||
#
|
||||
# Invisible (hardware-specific) Kconfig symbols
|
||||
#
|
||||
|
||||
config DEVICE_TYPE
|
||||
string
|
||||
help
|
||||
Device type name, e.g. MPPT-2420-LC
|
||||
|
||||
config HARDWARE_VERSION
|
||||
string
|
||||
help
|
||||
Version of the PCB
|
||||
|
||||
config HAS_LOAD_OUTPUT
|
||||
bool
|
||||
help
|
||||
PCB has a load output.
|
||||
|
||||
config HAS_USB_PWR_OUTPUT
|
||||
bool
|
||||
help
|
||||
PCB has a USB power output.
|
||||
|
||||
config CONTROL_FREQUENCY
|
||||
int
|
||||
default 10
|
||||
help
|
||||
Main control function frequency (Hz)
|
||||
|
||||
Frequencies higher than 10 Hz caused issues with MPPT control during lab test with
|
||||
PV simulator. Might be different with actual solar panel.
|
||||
|
||||
config MOSFET_MAX_JUNCTION_TEMP
|
||||
int
|
||||
default 120
|
||||
help
|
||||
Maximum Tj of MOSFETs (°C)
|
||||
|
||||
This value is used for model-based control of overcurrent protection. It represents
|
||||
the steady-state junction temperature for max. continuous current at ambient
|
||||
temperature of 25°C.
|
||||
|
||||
config INTERNAL_MAX_REFERENCE_TEMP
|
||||
int
|
||||
default 50
|
||||
help
|
||||
Internal reference temperature at full load (°C)
|
||||
|
||||
This value is used for model-based control of overcurrent protection. It represents
|
||||
the steady-state internal temperature for max. continuous current at ambient
|
||||
temperature of 25°C. Value here is conservative and can be overwritten in PCB
|
||||
configuration.
|
||||
|
||||
config MOSFET_THERMAL_TIME_CONSTANT
|
||||
int
|
||||
default 5
|
||||
help
|
||||
Thermal time constant junction to ambient (s)
|
||||
|
||||
This value is used for model-based control of overcurrent protection. It does not reflect
|
||||
the much lower MOSFET-internal time constant junction to case, but includes thermal
|
||||
inertia of the board.
|
||||
|
||||
Around 5s seems to be a good conservative estimation for 5x6 type SMD MOSFETs
|
||||
@@ -1,146 +0,0 @@
|
||||
# SPDX-License-Identifier: Apache-2.0
|
||||
# Copyright (c) 2019 Martin Jäger (Libre Solar)
|
||||
#
|
||||
# Visible (user-configurable) Kconfig symbols
|
||||
#
|
||||
|
||||
|
||||
choice
|
||||
prompt "High-voltage terminal"
|
||||
depends on $(dt_compat_enabled,dcdc)
|
||||
help
|
||||
Select the device connected to the high-voltage
|
||||
side terminal of the DC/DC converter.
|
||||
|
||||
config HV_TERMINAL_SOLAR
|
||||
bool "Solar panel"
|
||||
|
||||
config HV_TERMINAL_NANOGRID
|
||||
bool "DC nanogrid"
|
||||
|
||||
config HV_TERMINAL_GENERATOR
|
||||
bool "DC generator, e.g. wind turbine"
|
||||
|
||||
config HV_TERMINAL_BATTERY
|
||||
bool "Battery, e.g. electric bicycle"
|
||||
endchoice
|
||||
|
||||
|
||||
choice
|
||||
prompt "Low-voltage terminal"
|
||||
help
|
||||
Select the device connected to the low-voltage side
|
||||
of the charge controller (usually battery terminal).
|
||||
|
||||
config LV_TERMINAL_BATTERY
|
||||
depends on !HV_TERMINAL_BATTERY
|
||||
bool "Battery 12V/24V"
|
||||
|
||||
config LV_TERMINAL_SOLAR
|
||||
depends on HV_TERMINAL_BATTERY || HV_TERMINAL_NANOGRID
|
||||
bool "Solar panel"
|
||||
endchoice
|
||||
|
||||
|
||||
choice
|
||||
prompt "PWM terminal"
|
||||
depends on $(dt_compat_enabled,pwm-switch)
|
||||
help
|
||||
Select the device connected to the PWM switch (currently
|
||||
only solar panel possible)
|
||||
|
||||
config PWM_TERMINAL_SOLAR
|
||||
depends on LV_TERMINAL_BATTERY && !HV_TERMINAL_SOLAR
|
||||
bool "Solar panel"
|
||||
endchoice
|
||||
|
||||
|
||||
menu "Battery configuration"
|
||||
|
||||
choice
|
||||
prompt "Default battery cell type"
|
||||
default BAT_DEFAULT_TYPE_GEL
|
||||
help
|
||||
Select the type of the single cells inside the battery
|
||||
to determine voltage set points. Total voltage set points
|
||||
are multiplied with the selected number of cells.
|
||||
|
||||
config BAT_DEFAULT_TYPE_FLOODED
|
||||
bool "Flooded (wet) lead-acid"
|
||||
|
||||
config BAT_DEFAULT_TYPE_GEL
|
||||
bool "VRLA gel, maintainance-free"
|
||||
|
||||
config BAT_DEFAULT_TYPE_AGM
|
||||
bool "AGM, maintainance-free"
|
||||
|
||||
config BAT_DEFAULT_TYPE_LFP
|
||||
bool "LiFePO4 Li-ion, 3.3V nominal"
|
||||
|
||||
config BAT_DEFAULT_TYPE_NMC
|
||||
bool "NMC/Graphite Li-ion, 3.7V nominal, 4.2V max"
|
||||
|
||||
config BAT_DEFAULT_TYPE_NMC_HV
|
||||
bool "NMC/Graphite High Voltage Li-ion, 3.7V nominal, 4.35 max"
|
||||
|
||||
endchoice
|
||||
|
||||
config BAT_DEFAULT_NUM_CELLS
|
||||
int "Default number of battery cells"
|
||||
default 6
|
||||
range 3 16
|
||||
help
|
||||
Typical choices:
|
||||
- 6 for 12V lead-acid battery
|
||||
- 4 for 12V LiFePO4 battery
|
||||
- 3 for 12V NMC Li-ion battery
|
||||
|
||||
Remarks:
|
||||
- If you choose settings for 12V system, 24V systems
|
||||
(2 batteries in series) are recognized automatically
|
||||
- Make sure the voltage of the used charge controller
|
||||
is not exceeded.
|
||||
|
||||
config BAT_DEFAULT_CAPACITY_AH
|
||||
int "Default battery capacity in Ah"
|
||||
range 10 200
|
||||
default 50
|
||||
|
||||
endmenu
|
||||
|
||||
|
||||
menu "Extensions and interfaces"
|
||||
|
||||
config EXT_OLED_DISPLAY
|
||||
bool "OLED display at UEXT"
|
||||
|
||||
config EXT_OLED_BRIGHTNESS
|
||||
depends on EXT_OLED_DISPLAY
|
||||
int "OLED display brightness"
|
||||
range 1 255
|
||||
default 1
|
||||
|
||||
config EXT_THINGSET_SERIAL
|
||||
bool "ThingSet serial interface"
|
||||
|
||||
config EXT_THINGSET_SERIAL_RX_BUF_SIZE
|
||||
depends on EXT_THINGSET_SERIAL
|
||||
int "ThingSet serial RX buffer size"
|
||||
range 64 2048
|
||||
default 512
|
||||
|
||||
config EXT_THINGSET_SERIAL_TX_BUF_SIZE
|
||||
depends on EXT_THINGSET_SERIAL
|
||||
int "ThingSet serial TX buffer size"
|
||||
range 256 2048
|
||||
default 1024
|
||||
|
||||
config EXT_THINGSET_CAN
|
||||
depends on CAN
|
||||
bool "ThingSet CAN interface"
|
||||
|
||||
config DEVICE_ID
|
||||
int "Initial device ID for communication interfaces"
|
||||
default 0
|
||||
|
||||
endmenu
|
||||
@@ -11,7 +11,7 @@
|
||||
model = "Libre Solar MPPT 1210 HUS v0.4";
|
||||
compatible = "st,stm32l073";
|
||||
|
||||
charge-controller {
|
||||
pcb {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <40>;
|
||||
ls-voltage-max = <16>;
|
||||
|
||||
@@ -11,7 +11,7 @@
|
||||
model = "Libre Solar MPPT 1210 HUS v0.7";
|
||||
compatible = "st,stm32l073";
|
||||
|
||||
charge-controller {
|
||||
pcb {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <40>;
|
||||
ls-voltage-max = <16>;
|
||||
|
||||
@@ -42,7 +42,7 @@
|
||||
};
|
||||
};
|
||||
|
||||
charge-controller {
|
||||
pcb {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <80>;
|
||||
ls-voltage-max = <32>;
|
||||
|
||||
@@ -11,7 +11,7 @@
|
||||
model = "Libre Solar MPPT 2420 LC v0.10";
|
||||
compatible = "st,stm32f072";
|
||||
|
||||
charge-controller {
|
||||
pcb {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <55>;
|
||||
ls-voltage-max = <32>;
|
||||
|
||||
@@ -17,12 +17,6 @@
|
||||
|
||||
#define LOAD_CURRENT_MAX 15 // PCB maximum load switch current
|
||||
|
||||
// The MCU, where internal temperature is measured, is close to the MOSFETs. Tests showed that
|
||||
// temperature at heat sink is only 10-20°C above measured internal temp. As PWM CC doesn't
|
||||
// use electrolytic cap for core charging function, internal temperature of 70°C can be allowed.
|
||||
// This value is used for thermal overcurrent model.
|
||||
#define INTERNAL_MAX_REFERENCE_TEMP 70
|
||||
|
||||
#define PIN_UEXT_TX PA_2
|
||||
#define PIN_UEXT_RX PA_3
|
||||
#define PIN_UEXT_SCL PB_6
|
||||
|
||||
@@ -11,10 +11,15 @@
|
||||
model = "Libre Solar PWM 2420 LUS v0.3";
|
||||
compatible = "st,stm32l073";
|
||||
|
||||
charge-controller {
|
||||
pcb {
|
||||
compatible = "charge-controller";
|
||||
hs-voltage-max = <55>;
|
||||
ls-voltage-max = <32>;
|
||||
// The MCU, where internal temperature is measured, is close to the MOSFETs. Tests
|
||||
// showed that temperature at heat sink is only 10-20°C above measured internal
|
||||
// temp. As PWM CC doesn't use electrolytic cap for core charging function,
|
||||
// internal temperature of 70°C can be allowed (instead of default 50°C).
|
||||
internal-tref-max = <70>;
|
||||
};
|
||||
|
||||
pwm-switch {
|
||||
|
||||
+2
-2
@@ -39,8 +39,8 @@ Dcdc::Dcdc(PowerPort *hv_side, PowerPort *lv_side, DcdcOperationMode op_mode)
|
||||
lvs->neg_current_limit = -DT_INST_0_DCDC_CURRENT_MAX;
|
||||
lvs->pos_current_limit = DT_INST_0_DCDC_CURRENT_MAX;
|
||||
ls_current_max = DT_INST_0_DCDC_CURRENT_MAX;
|
||||
hs_voltage_max = DT_INST_0_CHARGE_CONTROLLER_HS_VOLTAGE_MAX;
|
||||
ls_voltage_max = DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX;
|
||||
hs_voltage_max = DT_CHARGE_CONTROLLER_PCB_HS_VOLTAGE_MAX;
|
||||
ls_voltage_max = DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX;
|
||||
ls_voltage_min = 9.0;
|
||||
output_power_min = 1; // switch off if power < 1 W
|
||||
restart_interval = 60;
|
||||
|
||||
+7
-8
@@ -43,13 +43,12 @@ void LoadOutput::control()
|
||||
|
||||
// junction temperature calculation model for overcurrent detection
|
||||
junction_temperature = junction_temperature + (
|
||||
dev_stat.internal_temp - junction_temperature +
|
||||
current * current /
|
||||
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) *
|
||||
(CONFIG_MOSFET_MAX_JUNCTION_TEMP - CONFIG_INTERNAL_MAX_REFERENCE_TEMP)
|
||||
) / (CONFIG_MOSFET_THERMAL_TIME_CONSTANT * CONFIG_CONTROL_FREQUENCY);
|
||||
dev_stat.internal_temp - junction_temperature + current * current /
|
||||
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) *
|
||||
(DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX - DT_CHARGE_CONTROLLER_PCB_INTERNAL_TREF_MAX)
|
||||
) / (DT_CHARGE_CONTROLLER_PCB_MOSFETS_TAU_JA * CONFIG_CONTROL_FREQUENCY);
|
||||
|
||||
if (junction_temperature > CONFIG_MOSFET_MAX_JUNCTION_TEMP ||
|
||||
if (junction_temperature > DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX ||
|
||||
current > LOAD_CURRENT_MAX * 2)
|
||||
{
|
||||
flags_set(&error_flags, ERR_LOAD_OVERCURRENT);
|
||||
@@ -69,7 +68,7 @@ void LoadOutput::control()
|
||||
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
|
||||
// off the solar input instead of the load output)
|
||||
if (bus->voltage > overvoltage || bus->voltage >
|
||||
DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX)
|
||||
DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX)
|
||||
{
|
||||
ov_debounce_counter++;
|
||||
if (ov_debounce_counter > CONFIG_CONTROL_FREQUENCY) {
|
||||
@@ -108,7 +107,7 @@ void LoadOutput::control()
|
||||
|
||||
if (flags_check(&error_flags, ERR_LOAD_OVERVOLTAGE) &&
|
||||
bus->voltage < (overvoltage - ov_hysteresis) &&
|
||||
bus->voltage < (DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX - ov_hysteresis))
|
||||
bus->voltage < (DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
flags_clear(&error_flags, ERR_LOAD_OVERVOLTAGE);
|
||||
}
|
||||
|
||||
+5
-5
@@ -42,14 +42,14 @@
|
||||
|
||||
// Values that are otherwise defined by Kconfig
|
||||
#define CONFIG_CONTROL_FREQUENCY 10 // Hz
|
||||
#define CONFIG_MOSFET_MAX_JUNCTION_TEMP 120
|
||||
#define CONFIG_INTERNAL_MAX_REFERENCE_TEMP 50
|
||||
#define CONFIG_MOSFET_THERMAL_TIME_CONSTANT 5
|
||||
#define DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX 120
|
||||
#define DT_CHARGE_CONTROLLER_PCB_INTERNAL_TREF_MAX 50
|
||||
#define DT_CHARGE_CONTROLLER_PCB_MOSFETS_TAU_JA 5
|
||||
|
||||
#define LOAD_CURRENT_MAX 20 // PCB maximum load switch current
|
||||
|
||||
#define DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX 32 // Maximum voltage at battery port (V)
|
||||
#define DT_INST_0_CHARGE_CONTROLLER_HS_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
#define DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX 32 // Maximum voltage at battery port (V)
|
||||
#define DT_CHARGE_CONTROLLER_PCB_HS_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
#define PIN_UEXT_TX 0
|
||||
#define PIN_UEXT_RX 0
|
||||
|
||||
+1
-1
@@ -106,7 +106,7 @@ void control_on_to_off_overcurrent()
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load_out.state);
|
||||
|
||||
// almost 2x current = 4x heat generation: Should definitely trigger after waiting one time constant
|
||||
int trigger_steps = CONFIG_MOSFET_THERMAL_TIME_CONSTANT * CONFIG_CONTROL_FREQUENCY;
|
||||
int trigger_steps = DT_CHARGE_CONTROLLER_PCB_MOSFETS_TAU_JA * CONFIG_CONTROL_FREQUENCY;
|
||||
for (int i = 0; i <= trigger_steps; i++) {
|
||||
load_out.control();
|
||||
}
|
||||
|
||||
@@ -14,3 +14,34 @@ properties:
|
||||
type: int
|
||||
required: true
|
||||
description: Maximum voltage at low-side (typically battery) in volts
|
||||
internal-tref-max:
|
||||
type: int
|
||||
default: 50
|
||||
description: |
|
||||
Internal reference temperature at full load (°C)
|
||||
|
||||
This value is used for model-based control of overcurrent protection. It represents
|
||||
the steady-state internal temperature for max. continuous current at ambient
|
||||
temperature of 25°C. Default value is conservative and can be overwritten in PCB
|
||||
configuration.
|
||||
mosfets-tj-max:
|
||||
type: int
|
||||
default: 120
|
||||
description: |
|
||||
Maximum Tj of MOSFETs (°C)
|
||||
|
||||
This value is used for model-based control of overcurrent protection. It represents
|
||||
the steady-state junction temperature for max. continuous current at ambient
|
||||
temperature of 25°C.
|
||||
mosfets-tau-ja:
|
||||
type: int
|
||||
default: 5
|
||||
description: |
|
||||
Thermal time constant junction to ambient (s)
|
||||
|
||||
This value is used for model-based control of overcurrent protection. It does not reflect
|
||||
the much lower MOSFET-internal time constant junction to case, but includes thermal
|
||||
inertia of the board.
|
||||
|
||||
Around 5s seems to be a good conservative estimation for 5x6 type SMD MOSFETs. Take larger
|
||||
values for big heat sinks.
|
||||
|
||||
Reference in New Issue
Block a user