Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage - Hysteresis for load overvoltage reconnect setpoint made configurable - Added check for PWM switch MOSFET driver undervoltage
This commit is contained in:
+3
-2
@@ -200,6 +200,7 @@ LoadOutput::LoadOutput(PowerPort *pwr_port) :
|
||||
junction_temperature = 25; // starting point: 25°C
|
||||
oc_recovery_delay = 5*60; // default: 5 minutes
|
||||
lvd_recovery_delay = 60*60; // default: 1 hour
|
||||
ov_hysteresis = 0.3;
|
||||
|
||||
// analog comparator to detect short circuits and trigger immediate load switch-off
|
||||
short_circuit_comp_init();
|
||||
@@ -341,8 +342,8 @@ void LoadOutput::control()
|
||||
}
|
||||
|
||||
if (dev_stat.has_error(ERR_LOAD_OVERVOLTAGE) &&
|
||||
port->voltage < (port->sink_voltage_max - 0.5) &&
|
||||
port->voltage < (LOW_SIDE_VOLTAGE_MAX - 0.5))
|
||||
port->voltage < (port->sink_voltage_max - ov_hysteresis) &&
|
||||
port->voltage < (LOW_SIDE_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
dev_stat.clear_error(ERR_LOAD_OVERVOLTAGE);
|
||||
}
|
||||
|
||||
@@ -111,6 +111,7 @@ public:
|
||||
float junction_temperature; ///< calculated using thermal model based on current and ambient
|
||||
///< temperature measurement (unit: °C)
|
||||
|
||||
float ov_hysteresis; ///< Hysteresis to switch back on after an overvoltage event
|
||||
private:
|
||||
int determine_load_state();
|
||||
|
||||
|
||||
+9
-15
@@ -28,7 +28,7 @@
|
||||
#include "config.h" // user-specific configuration
|
||||
|
||||
#include "half_bridge.h" // PWM generation for DC/DC converter
|
||||
#include "hardware.h" // hardware-related functions like load switch, LED control, watchdog, etc.
|
||||
#include "hardware.h" // hardware-related functions like watchdog, etc.
|
||||
#include "dcdc.h" // DC/DC converter control (hardware independent)
|
||||
#include "pwm_switch.h" // PWM charge controller
|
||||
#include "bat_charger.h" // battery settings and charger state machine
|
||||
@@ -133,13 +133,9 @@ int main()
|
||||
control_timer_start(CONTROL_FREQUENCY);
|
||||
wait(0.1); // necessary to prevent MCU from randomly getting stuck here if PV panel is connected before battery
|
||||
|
||||
|
||||
sleep_manager_lock_deep_sleep(); // required to have sleep returning.
|
||||
/*
|
||||
The mBed Serial class calls this internal during "attach", this is why it work with ThingSet Serial enabled even
|
||||
without this statement. Might be an issue of the particular STM32F072 mBed code or may affect
|
||||
also STM32L073 platforms on mBed
|
||||
*/
|
||||
// The Mbed Serial class calls sleep_manager_lock_deep_sleep() internally during attach. If no
|
||||
// Serial is enabled, sleep does not always return in STM32F072, so we lock deep sleep manually
|
||||
sleep_manager_lock_deep_sleep();
|
||||
|
||||
// the main loop is suitable for slow tasks like communication (even blocking wait allowed)
|
||||
time_t last_call = timestamp;
|
||||
@@ -149,9 +145,8 @@ int main()
|
||||
uext.process_asap();
|
||||
|
||||
time_t now = timestamp;
|
||||
if (now >= last_call + 1 || now < last_call) { // called once per second (or slower if blocking wait occured somewhere)
|
||||
|
||||
//printf("Still alive... time: %d, mode: %d\n", (int)time(NULL), dcdc.mode);
|
||||
if (now >= last_call + 1 || now < last_call) {
|
||||
// called once per second (or slower if blocking wait occured somewhere)
|
||||
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.charge_control(&bat_conf);
|
||||
@@ -163,10 +158,6 @@ int main()
|
||||
bat_terminal.pass_voltage_targets(&pwm_port_int);
|
||||
#endif
|
||||
|
||||
// update regularly to cover changed battery configurations
|
||||
adc_set_lv_alerts(bat_conf.voltage_absolute_max * charger.num_batteries,
|
||||
bat_conf.voltage_absolute_min * charger.num_batteries);
|
||||
|
||||
eeprom_update();
|
||||
|
||||
leds_update_1s();
|
||||
@@ -193,6 +184,9 @@ void system_control()
|
||||
// convert ADC readings to meaningful measurement values
|
||||
update_measurements();
|
||||
|
||||
// alerts should trigger only for transients, so update based on actual voltage
|
||||
adc_set_lv_alerts(lv_terminal.voltage * 1.2, lv_terminal.voltage * 0.8);
|
||||
|
||||
#if FEATURE_PWM_SWITCH
|
||||
ports_update_current_limits(&pwm_port_int, &bat_terminal, &load_terminal);
|
||||
pwm_switch.control();
|
||||
|
||||
+6
-2
@@ -83,8 +83,11 @@ extern "C" void TIM3_IRQHandler(void)
|
||||
{
|
||||
TIM3->SR &= ~TIM_SR_UIF; // clear update interrupt flag
|
||||
|
||||
// turning the PWM switch on creates a short voltage rise, so inhibit alerts by 10 ms
|
||||
adc_upper_alert_inhibit(ADC_POS_V_BAT, 10);
|
||||
if ((int)TIM3->CCR4 < _pwm_resolution) {
|
||||
// turning the PWM switch on creates a short voltage rise, so inhibit alerts by 10 ms
|
||||
// at each rising edge if switch is not continuously on
|
||||
adc_upper_alert_inhibit(ADC_POS_V_BAT, 10);
|
||||
}
|
||||
}
|
||||
|
||||
void pwm_signal_set_duty_cycle(float duty)
|
||||
@@ -180,6 +183,7 @@ void PwmSwitch::control()
|
||||
if (_pwm_active) {
|
||||
if (port_int->pos_current_limit == 0 || terminal->neg_current_limit == 0
|
||||
|| terminal->current > 0 // discharging battery into solar panel --> stop
|
||||
|| port_int->voltage < 9.0 // not enough voltage for MOSFET drivers anymore
|
||||
|| enabled == false)
|
||||
{
|
||||
pwm_signal_stop();
|
||||
|
||||
+2
-2
@@ -37,7 +37,7 @@ void control_pgood_to_off_overvoltage()
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_ON;
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
port.voltage = 14.8;
|
||||
port.voltage = port.sink_voltage_max + 0.6;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONTROL_FREQUENCY; i++) {
|
||||
@@ -252,7 +252,7 @@ void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
|
||||
port.voltage = port.sink_voltage_max - 0.6;
|
||||
port.voltage = port.sink_voltage_max - load.ov_hysteresis - 0.1;
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(0, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state); // deprecated
|
||||
|
||||
Reference in New Issue