Commit Graph
52 Commits
Author SHA1 Message Date
Martin Jäger 483e09d1a2 Use generic Copyright notice in all files 2021-03-12 18:40:22 +01:00
Martin Jäger 35b390ff24 Battery voltage & current filtering to improve charging algorithm
For PWM charge controllers, the topping stage was sometimes very short
and the battery did not get fully charged.

This commit adds a voltage_filtered and current_filtered member variable
to DcBus and PowerPort classes which can hold measurements more heavily
filtered (initial time constant setting: 10 seconds). This should fix
above issues with the charging algorithm.
2021-02-04 17:28:52 +01:00
Martin Jäger 2de110b0b7 Half bridge: New dts binding to fix pinmux
The previous approach to define the pinmux in the timer nodes didn't work
because the timers don't have a pinctrl-0 property. This commit adds a new
half-bridge binding similar to upstream Zephyr pwm binding, which is a child
node of the used timer.

It makes sense to define PWM frequency and dead-time also in this node, so
the dcdc devicetree binding is redundant and therefore removed.
2021-02-04 17:28:52 +01:00
Martin Jäger 4eaf89154a Use BOARD_HAS_* macro to identify key hardware features
These macros replace the direct use of DT_ macros in many locations and make
the code more readable.
2021-02-04 17:28:52 +01:00
Daniel Fanache 9ba540ec8c Configurable log levels for all the modules using Zephyr's logging.
This allows us to enable e.g debug output for the CAN module with
CONFIG_CAN_LOG_LEVEL=4 without enabling the global
CONFIG_LOG_DEFAULT_LEVEL=4 and being swamped with debug output from
all of Zephyr's subsytems.
2020-12-13 11:06:02 +01:00
Martin Jäger 0756341b29 Rename src/sink_voltage_bound to _intercept
These variables define the voltage at zero current, which is the y axis
intercept of the droop curve (voltage vs. current).
As they do not always specifiy minimum or maximum boundary depending on
the sign of the droop resistance, intercept is a more suitable name.
2020-11-05 20:42:00 +01:00
Martin Jäger ab63204adb Make battery configurable via Kconfig (fix #94)
Also adds crazy IS_ENABLED macro to unit tests.
2020-08-19 15:55:15 +02:00
Martin Jäger c2ef955a63 Replace custom print_* with Zephyr LOG_* 2020-07-23 17:34:41 +02:00
Martin Jäger dc4576c8b4 Remove all board.h files
Final updates to devicetree files (adding temperature sensor information) make
board.h files obsolete.
2020-07-23 17:34:41 +02:00
Martin Jäger a584904470 Switch to new DT_ macros 2020-07-23 17:34:39 +02:00
Martin Jäger b8fe6d7023 Fix some static code analysis warnings 2020-07-23 12:55:38 +02:00
Martin Jäger 3eb70e9a01 Add test/zephyr.h to mock Zephyr functions/defines 2020-06-04 16:28:19 +02:00
Martin Jäger 882f281333 Fix undervoltage error flag reporting
Load shedding should only trigger capacity calculation, but not set the
undervoltage flag. That flag is only set for voltage below absolute min.
2020-05-11 14:09:27 +02:00
Martin Jäger e1c7f97f63 Add support for devices without load output 2020-05-11 10:32:24 +02:00
Martin Jäger ce7f63b888 Introduce generic "outputs" DTS binding
Replaces previous "switch" and "pwm-out" bindings and allows to reference
either gpio or pwm handle and specify maximum current.

Also replacing CONFIG_HAS_LOAD and CONFIG_HAS_USB_PWR with DT_ variants.
2020-05-06 12:53:26 +02:00
Martin Jäger 1252a1ffa1 Make default battery type configurable via Kconfig 2020-05-06 12:53:26 +02:00
Martin Jäger 2a71d02aeb Move PCB and user config to board Kconfig
Files in src/pcbs/xyz.h are moved to boards/xyz/board.h. User settings from
src/config.h are also configured via Kconfig, so the file is removed.
2020-04-30 10:53:58 +02:00
Martin Jäger daf43fb967 USB charging output control via LoadOutput class
- Introduce new CONFIG_HAS_USB_PWR_OUTPUT
- Improve charger.discharge_control function
- Add battery empty flag
2020-03-02 11:55:38 +01:00
Martin Jäger 1a9c290485 Charger.num_batteries moved to DcBus.series_multiplier
The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
2020-03-01 09:48:35 +01:00
Martin Jäger 0c20545f88 Differentiate between src and sink droop res again
Necessary for improved load disconnect switch behavior.
2020-02-19 14:34:40 +01:00
Martin Jaeger 6af8e6d93d Improve load voltage limits setup and update 2020-02-19 14:34:40 +01:00
Martin Jaeger 68e0336279 Add debounce counter for UV error detection
This prevents switching off the load output due to short undervoltage
events during startup of pumps etc. when the battery is at low SOC.
2020-02-19 14:34:40 +01:00
JordanSilverman 30968e471c Check incoming battery conf 2020-02-17 19:47:51 +01:00
Martin Jaeger 14249492a3 Improve full charge detection and topping control
The battery is only full if the topping voltage is still reached AND the
current is below cut-off threshold at the same time. This was not always
detected correctly with previous 2s target voltage monitoring interval.

In addition to that, a new timer was introduced to count seconds at target
voltage and improve full charge detection due to timeout.
2020-02-10 12:47:32 +00:00
Martin Jaeger 43f90eea7c Move voltage control parameters to DcBus class
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
2020-02-07 12:03:25 +01:00
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger eed8c9114c Coding style updated/fixed
Indentations of class definitions and preprocessor statements were not
uniform throughout the code. This commit cleans up indentations as well
as the order of include statements.

Style conventions see: https://github.com/LibreSolar/coding-style
2020-01-28 13:20:01 +01:00
Martin Jaeger a76b92c27b time(NULL) replaced with uptime() in helper files
Reason: Zephyr does not support time(NULL). This way it is portable.
2020-01-16 20:04:37 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
hogthrob d1ff837c5e Overvoltage limit overflow fix (#80)
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.

Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
2019-11-10 17:55:43 +01:00
Martin Jaeger c26c17221a Overvoltage alert improved for PWM switching
Previously, the alert was sometimes erroneously triggered in PWM charger
absorption phase (constant voltage, PWM switching). Now the overvoltage
alert is inhibited during turn-on in each PWM cycle by an interrupt.
2019-11-08 13:06:17 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
hogthrob fd474e5350 Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code
completion), no performance loss due to inlining.
2019-11-02 08:22:00 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00
Martin Jaeger 68ae3227cc Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
2019-10-24 16:04:32 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger 515b098e85 Passing of bat voltage and current limits to other ports updated 2019-10-23 07:29:05 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 0545131a99 Equalization charging phase added 2019-10-16 10:02:27 +02:00
Martin Jaeger 6d91e075b3 Update of DC/DC lv side targets based on bat + load 2019-10-15 16:46:24 +02:00
Martin Jaeger 0a2a38691b 12V/24V battery detection message updated (closes #43) 2019-08-08 11:36:13 +02:00
Martin Jaeger c968a6bb8a Structs renamed for new coding style (closes #42) 2019-08-08 10:16:16 +02:00
Martin Jaeger 4bc3f8bd1e Load voltage thresholds adjusted and inhibit added
During tests, the deep discharge counter increased by several 100 counts per day under certain circumstances, most probably because of quite small battery making the voltage toggle between disconnect and reconnect voltage. This commit suggests several improvements.

- Load reconnect voltage increased
- Don't reconnect before waiting at least 1h (lvd_timestamp in load.cpp)
- SOC filter calculation slightly changed to make sure 100% is reached fast enough.
2019-07-12 18:55:13 +02:00
Martin Jaeger cf5366c2ba Fix usable_capacity estimation to prevent wrong values before first full charge 2019-07-11 13:11:34 +02:00
Hogthrob f26fdce41f Fixed NMC battery configuration calculation
Now num_cell multiplier is used in all required places.
2019-06-20 07:26:39 +02:00
Martin Jaeger 977002b0e7 Sign for discharged Ah counter corrected 2019-05-27 11:21:35 +02:00
Martin Jaeger dec36143dd 12V/24V detection added and bat_charger restructured 2019-05-23 22:16:41 +02:00