For PWM charge controllers, the topping stage was sometimes very short
and the battery did not get fully charged.
This commit adds a voltage_filtered and current_filtered member variable
to DcBus and PowerPort classes which can hold measurements more heavily
filtered (initial time constant setting: 10 seconds). This should fix
above issues with the charging algorithm.
The previous approach to define the pinmux in the timer nodes didn't work
because the timers don't have a pinctrl-0 property. This commit adds a new
half-bridge binding similar to upstream Zephyr pwm binding, which is a child
node of the used timer.
It makes sense to define PWM frequency and dead-time also in this node, so
the dcdc devicetree binding is redundant and therefore removed.
This allows us to enable e.g debug output for the CAN module with
CONFIG_CAN_LOG_LEVEL=4 without enabling the global
CONFIG_LOG_DEFAULT_LEVEL=4 and being swamped with debug output from
all of Zephyr's subsytems.
These variables define the voltage at zero current, which is the y axis
intercept of the droop curve (voltage vs. current).
As they do not always specifiy minimum or maximum boundary depending on
the sign of the droop resistance, intercept is a more suitable name.
Replaces previous "switch" and "pwm-out" bindings and allows to reference
either gpio or pwm handle and specify maximum current.
Also replacing CONFIG_HAS_LOAD and CONFIG_HAS_USB_PWR with DT_ variants.
The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
The battery is only full if the topping voltage is still reached AND the
current is below cut-off threshold at the same time. This was not always
detected correctly with previous 2s target voltage monitoring interval.
In addition to that, a new timer was introduced to count seconds at target
voltage and improve full charge detection due to timeout.
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
Indentations of class definitions and preprocessor statements were not
uniform throughout the code. This commit cleans up indentations as well
as the order of include statements.
Style conventions see: https://github.com/LibreSolar/coding-style
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.
Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
Previously, the alert was sometimes erroneously triggered in PWM charger
absorption phase (constant voltage, PWM switching). Now the overvoltage
alert is inhibited during turn-on in each PWM cycle by an interrupt.
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.
With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
During tests, the deep discharge counter increased by several 100 counts per day under certain circumstances, most probably because of quite small battery making the voltage toggle between disconnect and reconnect voltage. This commit suggests several improvements.
- Load reconnect voltage increased
- Don't reconnect before waiting at least 1h (lvd_timestamp in load.cpp)
- SOC filter calculation slightly changed to make sure 100% is reached fast enough.