Fix some static code analysis warnings
This commit is contained in:
@@ -134,24 +134,25 @@ The documentation auto-generated by Doxygen can be found [here](https://libre.so
|
||||
## Conformance testing
|
||||
|
||||
We are using Travis CI to perform several checks for each commit or pull-request. In order to run
|
||||
the same tests locally (recommended before each pull-request) use the script `check.sh` or ` check.bat`:
|
||||
the same tests locally (recommended before pushing to the server) use the script `check.sh` or ` check.bat`:
|
||||
|
||||
bash check.sh # Linux
|
||||
cmd check.bat # Windows
|
||||
|
||||
### Unit-tests
|
||||
|
||||
In order to run the unit tests, you need a PlatformIO Plus account. Run tests with the following command:
|
||||
Core functions of the firmware are covered by unit-tests (located in test directory). Run the tests with the following command:
|
||||
|
||||
platformio test -e unit-test-native
|
||||
platformio test -e unit_test
|
||||
|
||||
### Static code analysis
|
||||
|
||||
PlatformIO integrates cppcheck and clangtidy. The following command is an example to run the checks for MPPT 1210 HUS charge controller code:
|
||||
|
||||
platformio check -e mppt-1210-hus-v0.7
|
||||
platformio check -e mppt_1210_hus
|
||||
|
||||
## Additional firmware documentation (docs folder)
|
||||
|
||||
- [MPPT charger firmware details](docs/firmware.md)
|
||||
- [Charger state machine](docs/charger.md)
|
||||
- [Charge controller basic concepts](docs/charger-concepts.md)
|
||||
|
||||
- [Firmware module overview](docs/module-overview.md)
|
||||
|
||||
+69
-63
@@ -30,15 +30,15 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa
|
||||
bat->nominal_capacity = nominal_capacity;
|
||||
|
||||
// 1C should be safe for all batteries
|
||||
bat->charge_current_max = bat->nominal_capacity;
|
||||
bat->charge_current_max = bat->nominal_capacity;
|
||||
bat->discharge_current_max = bat->nominal_capacity;
|
||||
|
||||
bat->time_limit_recharge = 60; // sec
|
||||
bat->topping_duration = 120*60; // sec
|
||||
bat->topping_duration = 120*60; // sec
|
||||
|
||||
bat->charge_temp_max = 50;
|
||||
bat->charge_temp_min = -10;
|
||||
bat->discharge_temp_max = 50;
|
||||
bat->charge_temp_max = 50;
|
||||
bat->charge_temp_min = -10;
|
||||
bat->discharge_temp_max = 50;
|
||||
bat->discharge_temp_min = -10;
|
||||
|
||||
switch (type)
|
||||
@@ -46,91 +46,100 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa
|
||||
case BAT_TYPE_FLOODED:
|
||||
case BAT_TYPE_AGM:
|
||||
case BAT_TYPE_GEL:
|
||||
bat->voltage_absolute_max = num_cells * 2.45;
|
||||
bat->topping_voltage = num_cells * 2.4;
|
||||
bat->voltage_recharge = num_cells * 2.3;
|
||||
bat->voltage_absolute_max = static_cast<float>(num_cells) * 2.45F;
|
||||
bat->topping_voltage = static_cast<float>(num_cells) * 2.4F;
|
||||
bat->voltage_recharge = static_cast<float>(num_cells) * 2.3F;
|
||||
|
||||
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
|
||||
bat->voltage_load_disconnect = num_cells * 1.95;
|
||||
bat->voltage_load_reconnect = num_cells * 2.10;
|
||||
bat->voltage_load_disconnect = static_cast<float>(num_cells) * 1.95F;
|
||||
bat->voltage_load_reconnect = static_cast<float>(num_cells) * 2.10F;
|
||||
|
||||
// assumption: Battery selection matching charge controller
|
||||
bat->internal_resistance = num_cells * (1.95 - 1.80) / DISCHARGE_CURRENT_MAX;
|
||||
bat->internal_resistance = static_cast<float>(num_cells) * (1.95F - 1.80F) /
|
||||
DISCHARGE_CURRENT_MAX;
|
||||
|
||||
bat->voltage_absolute_min = num_cells * 1.6;
|
||||
bat->voltage_absolute_min = static_cast<float>(num_cells) * 1.6F;
|
||||
|
||||
// Voltages during idle (no charging/discharging current)
|
||||
bat->ocv_full = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.10 : 2.15);
|
||||
bat->ocv_empty = num_cells * 1.90;
|
||||
bat->ocv_full = static_cast<float>(num_cells) *
|
||||
((type == BAT_TYPE_FLOODED) ? 2.10F : 2.15F);
|
||||
bat->ocv_empty = static_cast<float>(num_cells) * 1.90F;
|
||||
|
||||
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
||||
bat->topping_current_cutoff = bat->nominal_capacity * 0.04; // 3-5 % of C/1
|
||||
bat->topping_current_cutoff = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
|
||||
|
||||
bat->trickle_enabled = true;
|
||||
bat->trickle_recharge_time = 30*60;
|
||||
bat->trickle_enabled = true;
|
||||
bat->trickle_recharge_time = 30*60;
|
||||
// Values as suggested in EN 62509:2011
|
||||
bat->trickle_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3);
|
||||
bat->trickle_voltage = static_cast<float>(num_cells) *
|
||||
((type == BAT_TYPE_FLOODED) ? 2.35F : 2.3F);
|
||||
|
||||
// Enable for flooded batteries only, according to
|
||||
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
|
||||
bat->equalization_enabled = false;
|
||||
bat->equalization_enabled = false;
|
||||
// Values as suggested in EN 62509:2011
|
||||
bat->equalization_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45);
|
||||
bat->equalization_duration = 60*60;
|
||||
bat->equalization_current_limit = (1.0 / 7.0) * bat->nominal_capacity;
|
||||
bat->equalization_voltage = static_cast<float>(num_cells) *
|
||||
((type == BAT_TYPE_FLOODED) ? 2.50F : 2.45F);
|
||||
bat->equalization_duration = 60*60;
|
||||
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
|
||||
bat->equalization_trigger_days = 60;
|
||||
bat->equalization_trigger_deep_cycles = 10;
|
||||
|
||||
bat->temperature_compensation = -0.003; // -3 mV/°C/cell
|
||||
bat->temperature_compensation = -0.003F; // -3 mV/°C/cell
|
||||
break;
|
||||
|
||||
case BAT_TYPE_LFP:
|
||||
bat->voltage_absolute_max = num_cells * 3.60;
|
||||
bat->topping_voltage = num_cells * 3.55; // CV voltage
|
||||
bat->voltage_recharge = num_cells * 3.35;
|
||||
bat->voltage_absolute_max = static_cast<float>(num_cells) * 3.60F;
|
||||
bat->topping_voltage = static_cast<float>(num_cells) * 3.55F; // CV voltage
|
||||
bat->voltage_recharge = static_cast<float>(num_cells) * 3.35F;
|
||||
|
||||
bat->voltage_load_disconnect = num_cells * 3.0;
|
||||
bat->voltage_load_reconnect = num_cells * 3.15;
|
||||
bat->voltage_load_disconnect = static_cast<float>(num_cells) * 3.00F;
|
||||
bat->voltage_load_reconnect = static_cast<float>(num_cells) * 3.15F;
|
||||
|
||||
// 5% voltage drop at max current
|
||||
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / DISCHARGE_CURRENT_MAX;
|
||||
bat->voltage_absolute_min = num_cells * 2.0;
|
||||
bat->internal_resistance = bat->voltage_load_disconnect * 0.05F /
|
||||
DISCHARGE_CURRENT_MAX;
|
||||
bat->voltage_absolute_min = static_cast<float>(num_cells) * 2.0F;
|
||||
|
||||
bat->ocv_full = num_cells * 3.4; // will give really nonlinear SOC calculation
|
||||
bat->ocv_empty = num_cells * 3.0; // because of flat OCV of LFP cells...
|
||||
// will give really nonlinear SOC calculation because of flat OCV of LFP cells...
|
||||
bat->ocv_full = static_cast<float>(num_cells) * 3.4F;
|
||||
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
|
||||
|
||||
// C/10 cut-off at end of CV phase by default
|
||||
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
||||
|
||||
bat->trickle_enabled = false;
|
||||
bat->equalization_enabled = false;
|
||||
bat->temperature_compensation = 0.0;
|
||||
bat->temperature_compensation = 0;
|
||||
bat->charge_temp_min = 0;
|
||||
break;
|
||||
|
||||
case BAT_TYPE_NMC:
|
||||
case BAT_TYPE_NMC_HV:
|
||||
bat->topping_voltage = num_cells * ((type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20);
|
||||
bat->voltage_absolute_max = bat->topping_voltage + num_cells * 0.05;
|
||||
bat->voltage_recharge = num_cells * 3.9;
|
||||
bat->topping_voltage = static_cast<float>(num_cells) *
|
||||
((type == BAT_TYPE_NMC_HV) ? 4.35F : 4.20F);
|
||||
bat->voltage_absolute_max = bat->topping_voltage +
|
||||
static_cast<float>(num_cells) * 0.05F;
|
||||
bat->voltage_recharge = static_cast<float>(num_cells) * 3.9F;
|
||||
|
||||
bat->voltage_load_disconnect = num_cells * 3.3;
|
||||
bat->voltage_load_reconnect = num_cells * 3.6;
|
||||
bat->voltage_load_disconnect = static_cast<float>(num_cells) * 3.3F;
|
||||
bat->voltage_load_reconnect = static_cast<float>(num_cells) * 3.6F;
|
||||
|
||||
// 5% voltage drop at max current
|
||||
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / DISCHARGE_CURRENT_MAX;
|
||||
bat->internal_resistance = bat->voltage_load_disconnect * 0.05F /
|
||||
DISCHARGE_CURRENT_MAX;
|
||||
|
||||
bat->voltage_absolute_min = num_cells * 2.5;
|
||||
bat->voltage_absolute_min = static_cast<float>(num_cells) * 2.5F;
|
||||
|
||||
bat->ocv_full = num_cells * 4.0;
|
||||
bat->ocv_empty = num_cells * 3.0;
|
||||
bat->ocv_full = static_cast<float>(num_cells) * 4.0F;
|
||||
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
|
||||
|
||||
// C/10 cut-off at end of CV phase by default
|
||||
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
||||
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
||||
|
||||
bat->trickle_enabled = false;
|
||||
bat->equalization_enabled = false;
|
||||
bat->temperature_compensation = 0.0;
|
||||
bat->temperature_compensation = 0;
|
||||
bat->charge_temp_min = 0;
|
||||
break;
|
||||
|
||||
@@ -161,8 +170,8 @@ bool battery_conf_check(BatConf *bat_conf)
|
||||
);
|
||||
*/
|
||||
|
||||
return
|
||||
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
|
||||
return (
|
||||
bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
|
||||
bat_conf->voltage_recharge < (bat_conf->topping_voltage - 0.4) &&
|
||||
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
|
||||
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&
|
||||
@@ -177,7 +186,7 @@ bool battery_conf_check(BatConf *bat_conf)
|
||||
(bat_conf->trickle_enabled == false ||
|
||||
(bat_conf->trickle_voltage < bat_conf->topping_voltage &&
|
||||
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
|
||||
);
|
||||
);
|
||||
}
|
||||
|
||||
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
|
||||
@@ -221,7 +230,7 @@ void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *char
|
||||
|
||||
bool battery_conf_changed(BatConf *a, BatConf *b)
|
||||
{
|
||||
if (
|
||||
return (
|
||||
a->topping_voltage != b->topping_voltage ||
|
||||
a->voltage_recharge != b->voltage_recharge ||
|
||||
a->voltage_load_reconnect != b->voltage_load_reconnect ||
|
||||
@@ -241,15 +250,10 @@ bool battery_conf_changed(BatConf *a, BatConf *b)
|
||||
a->temperature_compensation != b->temperature_compensation ||
|
||||
a->internal_resistance != b->internal_resistance ||
|
||||
a->wire_resistance != b->wire_resistance
|
||||
) {
|
||||
return true;
|
||||
}
|
||||
else {
|
||||
return false;
|
||||
}
|
||||
);
|
||||
}
|
||||
|
||||
void Charger::detect_num_batteries(BatConf *bat)
|
||||
void Charger::detect_num_batteries(BatConf *bat) const
|
||||
{
|
||||
if (port->bus->voltage > bat->voltage_absolute_min * 2 &&
|
||||
port->bus->voltage < bat->voltage_absolute_max * 2)
|
||||
@@ -288,7 +292,7 @@ void Charger::update_soc(BatConf *bat_conf)
|
||||
soc = soc_filtered / 100;
|
||||
}
|
||||
|
||||
discharged_Ah += -port->current / 3600.0; // charged current is positive: change sign
|
||||
discharged_Ah += -port->current / 3600.0F; // charged current is positive: change sign
|
||||
}
|
||||
|
||||
void Charger::enter_state(int next_state)
|
||||
@@ -315,8 +319,8 @@ void Charger::discharge_control(BatConf *bat_conf)
|
||||
else {
|
||||
// slowly adapt new measurements with low-pass filter
|
||||
usable_capacity =
|
||||
0.8 * usable_capacity +
|
||||
0.2 * discharged_Ah;
|
||||
0.8F * usable_capacity +
|
||||
0.2F * discharged_Ah;
|
||||
}
|
||||
|
||||
// simple SOH estimation
|
||||
@@ -353,7 +357,7 @@ void Charger::discharge_control(BatConf *bat_conf)
|
||||
// discharging currently not allowed. should we allow it?
|
||||
|
||||
if (port->bus->voltage >=
|
||||
port->bus->src_control_voltage(bat_conf->voltage_absolute_min + 0.1))
|
||||
port->bus->src_control_voltage(bat_conf->voltage_absolute_min + 0.1F))
|
||||
{
|
||||
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
||||
}
|
||||
@@ -391,7 +395,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
}
|
||||
|
||||
if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) &&
|
||||
port->bus->voltage < (bat_conf->voltage_absolute_max - 0.5) * port->bus->series_multiplier)
|
||||
port->bus->voltage < (bat_conf->voltage_absolute_max - 0.5F) * port->bus->series_multiplier)
|
||||
{
|
||||
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
||||
}
|
||||
@@ -523,7 +527,7 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
}
|
||||
}
|
||||
|
||||
void Charger::init_terminal(BatConf *bat)
|
||||
void Charger::init_terminal(BatConf *bat) const
|
||||
{
|
||||
port->bus->sink_voltage_bound = bat->topping_voltage;
|
||||
port->bus->src_voltage_bound = bat->voltage_load_disconnect;
|
||||
@@ -537,12 +541,14 @@ void Charger::init_terminal(BatConf *bat)
|
||||
* droop_res is multiplied with number of series connected batteries to calculate control
|
||||
* voltage, so we need to divide by number of batteries here for correction
|
||||
*/
|
||||
port->bus->sink_droop_res = -bat->wire_resistance / port->bus->series_multiplier;
|
||||
port->bus->sink_droop_res = -bat->wire_resistance /
|
||||
static_cast<float>(port->bus->series_multiplier);
|
||||
|
||||
/*
|
||||
* In discharging direction also include battery internal resistance for current-compensation
|
||||
* of voltage setpoints
|
||||
*/
|
||||
port->bus->src_droop_res = -bat->wire_resistance / port->bus->series_multiplier
|
||||
port->bus->src_droop_res = -bat->wire_resistance /
|
||||
static_cast<float>(port->bus->series_multiplier)
|
||||
- bat->internal_resistance;
|
||||
}
|
||||
|
||||
+2
-2
@@ -362,7 +362,7 @@ public:
|
||||
/**
|
||||
* Detect if two batteries are connected in series (12V/24V auto-detection)
|
||||
*/
|
||||
void detect_num_batteries(BatConf *bat);
|
||||
void detect_num_batteries(BatConf *bat) const;
|
||||
|
||||
/**
|
||||
* Discharging control update (for load output), should be called once per second
|
||||
@@ -386,7 +386,7 @@ public:
|
||||
*
|
||||
* @param bat Configuration to be used for terminal setpoints
|
||||
*/
|
||||
void init_terminal(BatConf *bat);
|
||||
void init_terminal(BatConf *bat) const;
|
||||
|
||||
private:
|
||||
void enter_state(int next_state);
|
||||
|
||||
@@ -32,8 +32,6 @@ static volatile uint32_t adc_filtered[NUM_ADC_CH] = {};
|
||||
static volatile AdcAlert adc_alerts_upper[NUM_ADC_CH] = {};
|
||||
static volatile AdcAlert adc_alerts_lower[NUM_ADC_CH] = {};
|
||||
|
||||
extern DeviceStatus dev_stat;
|
||||
|
||||
/**
|
||||
* Average value for ADC channel
|
||||
*
|
||||
|
||||
@@ -268,6 +268,8 @@ static inline void adc_trigger_conversion(struct k_timer *timer_id)
|
||||
|
||||
static void DMA1_Channel1_IRQHandler(void *args)
|
||||
{
|
||||
ARG_UNUSED(args);
|
||||
|
||||
if ((DMA1->ISR & DMA_ISR_TCIF1) != 0) // Test if transfer completed on DMA channel 1
|
||||
{
|
||||
for (unsigned int i = 0; i < num_adc1_ch; i++) {
|
||||
|
||||
+2
-1
@@ -480,8 +480,9 @@ void data_nodes_update_conf()
|
||||
// TODO: check also for changes in Load/USB EnDefault
|
||||
changed = true; // temporary hack
|
||||
|
||||
if (changed)
|
||||
if (changed) {
|
||||
eeprom_store_data();
|
||||
}
|
||||
}
|
||||
|
||||
void data_nodes_init()
|
||||
|
||||
+2
-2
@@ -110,8 +110,8 @@ public:
|
||||
int32_t power_good_timestamp; ///< Last time the DC/DC reached above minimum output power
|
||||
|
||||
// maximum allowed values
|
||||
float ls_current_max; ///< Maximum low-side (inductor) current
|
||||
float hs_voltage_max; ///< Maximum high-side voltage
|
||||
float ls_current_max = 0; ///< Maximum low-side (inductor) current
|
||||
float hs_voltage_max = 0; ///< Maximum high-side voltage
|
||||
float ls_voltage_max; ///< Maximum low-side voltage
|
||||
float ls_voltage_min; ///< Minimum low-side voltage, e.g. for driver supply
|
||||
float output_power_min; ///< Minimum output power (if lower, DC/DC is switched off)
|
||||
|
||||
@@ -134,11 +134,11 @@ void DeviceStatus::update_min_max_values()
|
||||
}
|
||||
#endif
|
||||
|
||||
if (charger.bat_temperature > bat_temp_max) {
|
||||
if (charger.bat_temperature > static_cast<float>(bat_temp_max)) {
|
||||
bat_temp_max = charger.bat_temperature;
|
||||
}
|
||||
|
||||
if (internal_temp > int_temp_max) {
|
||||
if (internal_temp > static_cast<float>(int_temp_max)) {
|
||||
int_temp_max = internal_temp;
|
||||
}
|
||||
}
|
||||
|
||||
+2
-2
@@ -11,13 +11,13 @@
|
||||
// necessary for PlatformIO debug session
|
||||
void std::__throw_bad_alloc()
|
||||
{
|
||||
while (1) {}
|
||||
while (true) {}
|
||||
}
|
||||
|
||||
// necessary to compile Zephyr v2.2
|
||||
void std::__throw_length_error(char const*)
|
||||
{
|
||||
while (1) {}
|
||||
while (true) {}
|
||||
}
|
||||
|
||||
// we use code to self register objects at construction time.
|
||||
|
||||
+3
-3
@@ -10,7 +10,7 @@
|
||||
static int led_states[NUM_LEDS]; // must be one of enum LedState
|
||||
static int trigger_timeout[NUM_LEDS]; // seconds until trigger should end
|
||||
|
||||
static int blink_state = 1; // global state of all blinking LEDs
|
||||
static bool blink_state = true; // global state of all blinking LEDs
|
||||
|
||||
static bool charging = false;
|
||||
|
||||
@@ -26,7 +26,7 @@ void leds_update_thread()
|
||||
{
|
||||
int led_count = 0;
|
||||
int flicker_count = 0;
|
||||
bool flicker_state = 1;
|
||||
bool flicker_state = true;
|
||||
struct device *led_devs[NUM_LED_PINS];
|
||||
|
||||
int wdt_channel = sw_watchdog_register(1000);
|
||||
@@ -37,7 +37,7 @@ void leds_update_thread()
|
||||
|
||||
leds_init();
|
||||
|
||||
while (1) {
|
||||
while (true) {
|
||||
|
||||
sw_watchdog_feed(wdt_channel);
|
||||
|
||||
|
||||
+4
-4
@@ -76,7 +76,7 @@ void main(void)
|
||||
watchdog_start();
|
||||
sw_watchdog_start();
|
||||
|
||||
while (1) {
|
||||
while (true) {
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.charge_control(&bat_conf);
|
||||
|
||||
@@ -99,7 +99,7 @@ void control_thread()
|
||||
uint32_t last_call = 0;
|
||||
int wdt_channel = sw_watchdog_register(200);
|
||||
|
||||
while (1) {
|
||||
while (true) {
|
||||
|
||||
bool charging = false;
|
||||
|
||||
@@ -109,7 +109,7 @@ void control_thread()
|
||||
daq_update();
|
||||
|
||||
// alerts should trigger only for transients, so update based on actual voltage
|
||||
daq_set_lv_alerts(lv_terminal.bus->voltage * 1.2, lv_terminal.bus->voltage * 0.8);
|
||||
daq_set_lv_alerts(lv_terminal.bus->voltage * 1.2F, lv_terminal.bus->voltage * 0.8F);
|
||||
|
||||
lv_terminal.update_bus_current_margins();
|
||||
|
||||
@@ -181,7 +181,7 @@ void ext_mgr_thread()
|
||||
// quite long watchdog timeout as we might be dealing with slow communication (e.g. modems
|
||||
// using AT commands via serial interface)
|
||||
|
||||
while (1) {
|
||||
while (true) {
|
||||
|
||||
sw_watchdog_feed(wdt_channel);
|
||||
|
||||
|
||||
+3
-3
@@ -30,14 +30,14 @@ void PowerPort::energy_balance()
|
||||
{
|
||||
// remark: timespan = 1s, so no multiplication with time necessary for energy calculation
|
||||
if (current >= 0.0F) {
|
||||
pos_energy_Wh += bus->voltage * current / 3600.0;
|
||||
pos_energy_Wh += bus->voltage * current / 3600.0F;
|
||||
}
|
||||
else {
|
||||
neg_energy_Wh -= bus->voltage * current / 3600.0;
|
||||
neg_energy_Wh -= bus->voltage * current / 3600.0F;
|
||||
}
|
||||
}
|
||||
|
||||
void PowerPort::update_bus_current_margins()
|
||||
void PowerPort::update_bus_current_margins() const
|
||||
{
|
||||
// charging direction of battery
|
||||
bus->sink_current_margin = pos_current_limit - current;
|
||||
|
||||
+7
-7
@@ -176,32 +176,32 @@ public:
|
||||
/**
|
||||
* Measured current through this port (positive sign = current into the external device)
|
||||
*/
|
||||
float current;
|
||||
float current = 0;
|
||||
|
||||
/**
|
||||
* Product of port current and bus voltage
|
||||
*/
|
||||
float power;
|
||||
float power = 0;
|
||||
|
||||
/**
|
||||
* Maximum positive current (valid values >= 0.0)
|
||||
*/
|
||||
float pos_current_limit;
|
||||
float pos_current_limit = 0;
|
||||
|
||||
/**
|
||||
* Maximum negative current (valid values <= 0.0)
|
||||
*/
|
||||
float neg_current_limit;
|
||||
float neg_current_limit = 0;
|
||||
|
||||
/**
|
||||
* Cumulated energy in positive current direction since last counter reset (Wh)
|
||||
*/
|
||||
float pos_energy_Wh;
|
||||
float pos_energy_Wh = 0;
|
||||
|
||||
/**
|
||||
* Cumulated energy in negative current direction since last counter reset (Wh)
|
||||
*/
|
||||
float neg_energy_Wh;
|
||||
float neg_energy_Wh = 0;
|
||||
|
||||
/**
|
||||
* Constructor assigning the port to a DC bus
|
||||
@@ -241,7 +241,7 @@ public:
|
||||
* This function has to be called using the port defining the bus control targets, i.e.
|
||||
* the battery, the solar panel or the DC grid.
|
||||
*/
|
||||
void update_bus_current_margins();
|
||||
void update_bus_current_margins() const;
|
||||
};
|
||||
|
||||
#endif /* POWER_PORT_H */
|
||||
|
||||
+5
-1
@@ -88,7 +88,11 @@ uint32_t timestamp;
|
||||
|
||||
#include <zephyr.h>
|
||||
|
||||
static inline void timestamp_inc(struct k_timer *timer_id) { timestamp++; }
|
||||
static inline void timestamp_inc(struct k_timer *timer_id)
|
||||
{
|
||||
ARG_UNUSED(timer_id);
|
||||
timestamp++;
|
||||
}
|
||||
|
||||
void setup()
|
||||
{
|
||||
|
||||
Reference in New Issue