Fix usable_capacity estimation to prevent wrong values before first full charge

This commit is contained in:
Martin Jaeger
2019-07-11 13:11:34 +02:00
parent 5e48d5e7c5
commit cf5366c2ba
2 changed files with 11 additions and 4 deletions
+10 -4
View File
@@ -213,6 +213,7 @@ void charger_init(charger_t *charger)
charger->num_batteries = 1; // initialize with only one battery in series
charger->soh = 100; // assume new battery
charger->bat_temperature = 25.0;
charger->first_full_charge_reached = false;
}
void charger_detect_num_batteries(charger_t *charger, battery_conf_t *bat, dc_bus_t *bus)
@@ -267,16 +268,19 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c
{
//printf("time_state_change = %d, time = %d, v_bat = %f, i_bat = %f\n", charger->time_state_changed, time(NULL), voltage, current);
// Load management
// battery port input state (i.e. battery discharging direction) defines load state
// load output state is defined by battery bus dis_allowed flag
if (bus->dis_allowed == true
&& bus->voltage < (bat_conf->voltage_load_disconnect - bus->current * bus->dis_droop_res) * charger->num_batteries)
{
// low state of charge
bus->dis_allowed = false;
charger->num_deep_discharges++;
if (charger->usable_capacity < 0.1) {
charger->usable_capacity = charger->discharged_Ah;
// reset to measured value if discharged the first time
if (charger->first_full_charge_reached) {
charger->usable_capacity = charger->discharged_Ah;
}
} else {
// slowly adapt new measurements with low-pass filter
charger->usable_capacity = 0.8 * charger->usable_capacity + 0.2 * charger->discharged_Ah;
@@ -289,6 +293,7 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c
&& (charger->bat_temperature > bat_conf->discharge_temp_max
|| charger->bat_temperature < bat_conf->discharge_temp_min))
{
// temperature limits exceeded
bus->dis_allowed = false;
}
@@ -299,7 +304,7 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c
bus->dis_allowed = true;
}
// check battery temperature
// check battery temperature for charging direction
if (charger->bat_temperature > bat_conf->charge_temp_max
|| charger->bat_temperature < bat_conf->charge_temp_min)
{
@@ -348,6 +353,7 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c
charger->full = true;
charger->num_full_charges++;
charger->discharged_Ah = 0; // reset coulomb counter
charger->first_full_charge_reached = true;
/*if (bat_conf->equalization_enabled) {
// TODO: additional conditions!
+1
View File
@@ -250,6 +250,7 @@ typedef struct
int time_voltage_limit_reached; ///< Last time the CV limit was reached
bool full; ///< Flag to indicate if battery was fully charged
bool first_full_charge_reached; ///< Set to true if battery was fully charged at least once (necessary for proper capacity estimation)
} charger_t;