hogthrob d1ff837c5e Overvoltage limit overflow fix (#80)
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.

Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
2019-11-10 17:55:43 +01:00

489 lines
20 KiB
C++

/* LibreSolar charge controller firmware
* Copyright (c) 2016-2019 Martin Jäger (www.libre.solar)
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
#include "bat_charger.h"
#include "config.h"
#include "pcb.h"
#include "device_status.h"
extern DeviceStatus dev_stat;
#include <math.h> // for fabs function
#include <stdio.h>
#include <time.h>
void battery_conf_init(BatConf *bat, BatType type, int num_cells, float nominal_capacity)
{
bat->nominal_capacity = nominal_capacity;
// 1C should be safe for all batteries
bat->charge_current_max = bat->nominal_capacity;
bat->discharge_current_max = bat->nominal_capacity;
bat->time_limit_recharge = 60; // sec
bat->topping_duration = 120*60; // sec
bat->charge_temp_max = 50;
bat->charge_temp_min = -10;
bat->discharge_temp_max = 50;
bat->discharge_temp_min = -10;
switch (type)
{
case BAT_TYPE_FLOODED:
case BAT_TYPE_AGM:
case BAT_TYPE_GEL:
bat->voltage_absolute_max = num_cells * 2.45;
bat->topping_voltage = num_cells * 2.4;
bat->voltage_recharge = num_cells * 2.3;
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
bat->voltage_load_disconnect = num_cells * 1.95;
bat->voltage_load_reconnect = num_cells * 2.10;
// assumption: Battery selection matching charge controller
bat->internal_resistance = num_cells * (1.95 - 1.80) / LOAD_CURRENT_MAX;
bat->voltage_absolute_min = num_cells * 1.6;
// Voltages during idle (no charging/discharging current)
bat->ocv_full = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.10 : 2.15);
bat->ocv_empty = num_cells * 1.90;
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->topping_current_cutoff = bat->nominal_capacity * 0.04; // 3-5 % of C/1
bat->trickle_enabled = true;
bat->trickle_recharge_time = 30*60;
// Values as suggested in EN 62509:2011
bat->trickle_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3);
// Enable for flooded batteries only, according to
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
bat->equalization_enabled = false;
// Values as suggested in EN 62509:2011
bat->equalization_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45);
bat->equalization_duration = 60*60;
bat->equalization_current_limit = (1.0 / 7.0) * bat->nominal_capacity;
bat->equalization_trigger_days = 60;
bat->equalization_trigger_deep_cycles = 10;
bat->temperature_compensation = -0.003; // -3 mV/°C/cell
break;
case BAT_TYPE_LFP:
bat->voltage_absolute_max = num_cells * 3.60;
bat->topping_voltage = num_cells * 3.55; // CV voltage
bat->voltage_recharge = num_cells * 3.35;
bat->voltage_load_disconnect = num_cells * 3.0;
bat->voltage_load_reconnect = num_cells * 3.15;
// 5% voltage drop at max current
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX;
bat->voltage_absolute_min = num_cells * 2.0;
bat->ocv_full = num_cells * 3.4; // will give really nonlinear SOC calculation
bat->ocv_empty = num_cells * 3.0; // because of flat OCV of LFP cells...
// C/10 cut-off at end of CV phase by default
bat->topping_current_cutoff = bat->nominal_capacity / 10;
bat->trickle_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0.0;
bat->charge_temp_min = 0;
break;
case BAT_TYPE_NMC:
case BAT_TYPE_NMC_HV:
bat->topping_voltage = num_cells * ((type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20);
bat->voltage_absolute_max = bat->topping_voltage + num_cells * 0.05;
bat->voltage_recharge = num_cells * 3.9;
bat->voltage_load_disconnect = num_cells * 3.3;
bat->voltage_load_reconnect = num_cells * 3.6;
// 5% voltage drop at max current
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX;
bat->voltage_absolute_min = num_cells * 2.5;
bat->ocv_full = num_cells * 4.0;
bat->ocv_empty = num_cells * 3.0;
// C/10 cut-off at end of CV phase by default
bat->topping_current_cutoff = bat->nominal_capacity / 10;
bat->trickle_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0.0;
bat->charge_temp_min = 0;
break;
case BAT_TYPE_NONE:
break;
}
}
// checks settings in bat_conf for plausibility
bool battery_conf_check(BatConf *bat_conf)
{
// things to check:
// - load_disconnect/reconnect hysteresis makes sense?
// - cutoff current not extremely low/high
// - capacity plausible
/*
printf("battery_conf_check: %d %d %d %d %d %d %d\n",
bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.6),
bat_conf->voltage_recharge < (bat_conf->voltage_max - 0.4),
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1),
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4),
bat_conf->current_cutoff_CV < (bat_conf->nominal_capacity / 10.0), // C/10 or lower allowed
bat_conf->current_cutoff_CV > 0.01,
(bat_conf->trickle_enabled == false ||
(bat_conf->trickle_voltage < bat_conf->voltage_max &&
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
);
*/
return
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
bat_conf->voltage_recharge < (bat_conf->topping_voltage - 0.4) &&
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&
// max. 10% drop
bat_conf->internal_resistance < bat_conf->voltage_load_disconnect * 0.1 / LOAD_CURRENT_MAX &&
// max. 3% loss
bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / LOAD_CURRENT_MAX &&
// C/10 or lower current cutoff allowed
bat_conf->topping_current_cutoff < (bat_conf->nominal_capacity / 10.0) &&
bat_conf->topping_current_cutoff > 0.01 &&
(bat_conf->trickle_enabled == false ||
(bat_conf->trickle_voltage < bat_conf->topping_voltage &&
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
);
}
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
{
// TODO: stop DC/DC
destination->topping_voltage = source->topping_voltage;
destination->voltage_recharge = source->voltage_recharge;
destination->voltage_load_reconnect = source->voltage_load_reconnect;
destination->voltage_load_disconnect = source->voltage_load_disconnect;
destination->voltage_absolute_max = source->voltage_absolute_max;
destination->voltage_absolute_min = source->voltage_absolute_min;
destination->charge_current_max = source->charge_current_max;
destination->topping_current_cutoff = source->topping_current_cutoff;
destination->topping_duration = source->topping_duration;
destination->trickle_enabled = source->trickle_enabled;
destination->trickle_voltage = source->trickle_voltage;
destination->trickle_recharge_time = source->trickle_recharge_time;
destination->charge_temp_max = source->charge_temp_max;
destination->charge_temp_min = source->charge_temp_min;
destination->discharge_temp_max = source->discharge_temp_max;
destination->discharge_temp_min = source->discharge_temp_min;
destination->temperature_compensation = source->temperature_compensation;
destination->internal_resistance = source->internal_resistance;
destination->wire_resistance = source->wire_resistance;
// reset Ah counter and SOH if battery nominal capacity was changed
if (destination->nominal_capacity != source->nominal_capacity) {
destination->nominal_capacity = source->nominal_capacity;
if (charger != NULL) {
charger->discharged_Ah = 0;
charger->usable_capacity = 0;
charger->soh = 0;
}
}
// TODO:
// - update also DC/DC etc. (now this function only works at system startup)
// - restart DC/DC
}
void Charger::detect_num_batteries(BatConf *bat)
{
if (port->voltage > bat->voltage_absolute_min * 2 &&
port->voltage < bat->voltage_absolute_max * 2) {
num_batteries = 2;
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
}
else {
printf("Detected single battery (%.2f V max)\n", bat->topping_voltage);
}
}
void Charger::update_soc(BatConf *bat_conf)
{
static int soc_filtered = 0; // SOC / 100 for better filtering
if (fabs(port->current) < 0.2) {
int soc_new = (int)((port->voltage - bat_conf->ocv_empty) /
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
if (soc_new > 500 && soc_filtered == 0) {
// bypass filter during initialization
soc_filtered = soc_new;
}
else {
// filtering to adjust SOC very slowly
soc_filtered += (soc_new - soc_filtered) / 100;
}
if (soc_filtered > 10000) {
soc_filtered = 10000;
}
else if (soc_filtered < 0) {
soc_filtered = 0;
}
soc = soc_filtered / 100;
}
discharged_Ah += -port->current / 3600.0; // charged current is positive: change sign
}
void Charger::enter_state(int next_state)
{
//printf("Enter State: %d\n", next_state);
time_state_changed = time(NULL);
state = next_state;
}
void Charger::discharge_control(BatConf *bat_conf)
{
// load output state is defined by battery negative current limit
if (port->neg_current_limit < 0) {
// discharging currently allowed. see if that's still valid:
if (port->voltage < num_batteries *
(bat_conf->voltage_load_disconnect - port->current * port->neg_droop_res))
{
// low state of charge
port->neg_current_limit = 0;
num_deep_discharges++;
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
if (usable_capacity < 0.1) {
// reset to measured value if discharged the first time
if (first_full_charge_reached) {
usable_capacity = discharged_Ah;
}
}
else {
// slowly adapt new measurements with low-pass filter
usable_capacity =
0.8 * usable_capacity +
0.2 * discharged_Ah;
}
// simple SOH estimation
soh = usable_capacity / bat_conf->nominal_capacity;
}
else if (bat_temperature > bat_conf->discharge_temp_max) {
port->neg_current_limit = 0;
dev_stat.set_error(ERR_BAT_DIS_OVERTEMP);
}
else if (bat_temperature < bat_conf->discharge_temp_min) {
port->neg_current_limit = 0;
dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP);
}
}
else {
// discharging currently not allowed. should we allow it?
if (port->voltage >= num_batteries *
(bat_conf->voltage_load_reconnect - port->current * port->neg_droop_res)
&& bat_temperature < bat_conf->discharge_temp_max - 1
&& bat_temperature > bat_conf->discharge_temp_min + 1)
{
// discharge current is stored as absolute value in bat_conf, but defined
// as negative current for power port
port->neg_current_limit = -bat_conf->discharge_current_max;
// delete all discharge error flags
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP);
dev_stat.clear_error(ERR_BAT_DIS_UNDERTEMP);
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
}
}
}
void Charger::charge_control(BatConf *bat_conf)
{
// check battery temperature for charging direction
if (bat_temperature > bat_conf->charge_temp_max) {
port->pos_current_limit = 0;
dev_stat.set_error(ERR_BAT_CHG_OVERTEMP);
enter_state(CHG_STATE_IDLE);
}
else if (bat_temperature < bat_conf->charge_temp_min) {
port->pos_current_limit = 0;
dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP);
enter_state(CHG_STATE_IDLE);
}
if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) &&
port->voltage < (bat_conf->voltage_absolute_max - 0.5) * num_batteries)
{
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
}
// state machine
switch (state) {
case CHG_STATE_IDLE: {
if (port->voltage < bat_conf->voltage_recharge * num_batteries
&& (time(NULL) - time_state_changed) > bat_conf->time_limit_recharge
&& bat_temperature < bat_conf->charge_temp_max - 1
&& bat_temperature > bat_conf->charge_temp_min + 1)
{
port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
port->pos_current_limit = bat_conf->charge_current_max;
full = false;
dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP);
dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP);
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
enter_state(CHG_STATE_BULK);
}
break;
}
case CHG_STATE_BULK: {
// continuously adjust voltage setting for temperature compensation
port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
if (port->voltage > num_batteries *
(port->sink_voltage_max - port->current * port->pos_droop_res))
{
enter_state(CHG_STATE_TOPPING);
}
break;
}
case CHG_STATE_TOPPING: {
// continuously adjust voltage setting for temperature compensation
port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
if (port->voltage >= num_batteries *
(port->sink_voltage_max - port->current * port->pos_droop_res))
{
time_voltage_limit_reached = time(NULL);
}
// cut-off limit reached because battery full (i.e. CV limit still
// reached by available solar power within last 2s) or CV period long enough?
if ((port->current < bat_conf->topping_current_cutoff &&
(time(NULL) - time_voltage_limit_reached) < 2)
|| (time(NULL) - time_state_changed) > bat_conf->topping_duration)
{
full = true;
num_full_charges++;
discharged_Ah = 0; // reset coulomb counter
first_full_charge_reached = true;
if (bat_conf->equalization_enabled && (
(time(NULL) - time_last_equalization) / (24*60*60)
>= bat_conf->equalization_trigger_days ||
num_deep_discharges - deep_dis_last_equalization
>= bat_conf->equalization_trigger_deep_cycles))
{
port->sink_voltage_max = bat_conf->equalization_voltage;
port->pos_current_limit = bat_conf->equalization_current_limit;
enter_state(CHG_STATE_EQUALIZATION);
}
else if (bat_conf->trickle_enabled) {
port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
enter_state(CHG_STATE_TRICKLE);
}
else {
port->pos_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
case CHG_STATE_TRICKLE: {
// continuously adjust voltage setting for temperature compensation
port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
if (port->voltage >= num_batteries *
(port->sink_voltage_max - port->current * port->pos_droop_res))
{
time_voltage_limit_reached = time(NULL);
}
if (time(NULL) - time_voltage_limit_reached > bat_conf->trickle_recharge_time)
{
port->pos_current_limit = bat_conf->charge_current_max;
full = false;
enter_state(CHG_STATE_BULK);
}
// assumption: trickle does not harm the battery --> never go back to idle
// (for Li-ion battery: disable trickle!)
break;
}
case CHG_STATE_EQUALIZATION: {
// continuously adjust voltage setting for temperature compensation
port->sink_voltage_max = num_batteries * (bat_conf->equalization_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
// current or time limit for equalization reached
if (time(NULL) - time_state_changed > bat_conf->equalization_duration)
{
// reset triggers
time_last_equalization = time(NULL);
deep_dis_last_equalization = num_deep_discharges;
discharged_Ah = 0; // reset coulomb counter again
if (bat_conf->trickle_enabled) {
port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25));
enter_state(CHG_STATE_TRICKLE);
}
else {
port->pos_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
}
}
void battery_init_dc_bus(PowerPort *port, BatConf *bat, unsigned int num_batteries)
{
unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed
port->src_voltage_start = bat->voltage_load_reconnect * n;
port->src_voltage_stop = bat->voltage_load_disconnect * n;
port->neg_current_limit = -bat->discharge_current_max;
// negative sign for compensation of actual resistance
port->neg_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n;
port->sink_voltage_max = bat->topping_voltage * n;
port->sink_voltage_min = bat->voltage_absolute_min * n;
port->pos_current_limit = bat->charge_current_max;
// negative sign for compensation of actual resistance
port->pos_droop_res = -bat->wire_resistance * n;
}