The bat config calculation did calculate the absolute max voltage too high, it was doing an unnecessary multiplication. This triggered an issue in the voltage limit set code, which did not handle the overflow of the 16bit limit value properly. Both are fixed now. We limit the limit value to what the ADC is able to deliver, so that we detect overvoltage for sure, even if the setting is out of ADC range.
489 lines
20 KiB
C++
489 lines
20 KiB
C++
/* LibreSolar charge controller firmware
|
|
* Copyright (c) 2016-2019 Martin Jäger (www.libre.solar)
|
|
*
|
|
* Licensed under the Apache License, Version 2.0 (the "License");
|
|
* you may not use this file except in compliance with the License.
|
|
* You may obtain a copy of the License at
|
|
*
|
|
* http://www.apache.org/licenses/LICENSE-2.0
|
|
*
|
|
* Unless required by applicable law or agreed to in writing, software
|
|
* distributed under the License is distributed on an "AS IS" BASIS,
|
|
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
* See the License for the specific language governing permissions and
|
|
* limitations under the License.
|
|
*/
|
|
|
|
#include "bat_charger.h"
|
|
#include "config.h"
|
|
#include "pcb.h"
|
|
|
|
#include "device_status.h"
|
|
extern DeviceStatus dev_stat;
|
|
|
|
#include <math.h> // for fabs function
|
|
#include <stdio.h>
|
|
#include <time.h>
|
|
|
|
void battery_conf_init(BatConf *bat, BatType type, int num_cells, float nominal_capacity)
|
|
{
|
|
bat->nominal_capacity = nominal_capacity;
|
|
|
|
// 1C should be safe for all batteries
|
|
bat->charge_current_max = bat->nominal_capacity;
|
|
bat->discharge_current_max = bat->nominal_capacity;
|
|
|
|
bat->time_limit_recharge = 60; // sec
|
|
bat->topping_duration = 120*60; // sec
|
|
|
|
bat->charge_temp_max = 50;
|
|
bat->charge_temp_min = -10;
|
|
bat->discharge_temp_max = 50;
|
|
bat->discharge_temp_min = -10;
|
|
|
|
switch (type)
|
|
{
|
|
case BAT_TYPE_FLOODED:
|
|
case BAT_TYPE_AGM:
|
|
case BAT_TYPE_GEL:
|
|
bat->voltage_absolute_max = num_cells * 2.45;
|
|
bat->topping_voltage = num_cells * 2.4;
|
|
bat->voltage_recharge = num_cells * 2.3;
|
|
|
|
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
|
|
bat->voltage_load_disconnect = num_cells * 1.95;
|
|
bat->voltage_load_reconnect = num_cells * 2.10;
|
|
|
|
// assumption: Battery selection matching charge controller
|
|
bat->internal_resistance = num_cells * (1.95 - 1.80) / LOAD_CURRENT_MAX;
|
|
|
|
bat->voltage_absolute_min = num_cells * 1.6;
|
|
|
|
// Voltages during idle (no charging/discharging current)
|
|
bat->ocv_full = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.10 : 2.15);
|
|
bat->ocv_empty = num_cells * 1.90;
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->topping_current_cutoff = bat->nominal_capacity * 0.04; // 3-5 % of C/1
|
|
|
|
bat->trickle_enabled = true;
|
|
bat->trickle_recharge_time = 30*60;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->trickle_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3);
|
|
|
|
// Enable for flooded batteries only, according to
|
|
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
|
|
bat->equalization_enabled = false;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->equalization_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45);
|
|
bat->equalization_duration = 60*60;
|
|
bat->equalization_current_limit = (1.0 / 7.0) * bat->nominal_capacity;
|
|
bat->equalization_trigger_days = 60;
|
|
bat->equalization_trigger_deep_cycles = 10;
|
|
|
|
bat->temperature_compensation = -0.003; // -3 mV/°C/cell
|
|
break;
|
|
|
|
case BAT_TYPE_LFP:
|
|
bat->voltage_absolute_max = num_cells * 3.60;
|
|
bat->topping_voltage = num_cells * 3.55; // CV voltage
|
|
bat->voltage_recharge = num_cells * 3.35;
|
|
|
|
bat->voltage_load_disconnect = num_cells * 3.0;
|
|
bat->voltage_load_reconnect = num_cells * 3.15;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX;
|
|
bat->voltage_absolute_min = num_cells * 2.0;
|
|
|
|
bat->ocv_full = num_cells * 3.4; // will give really nonlinear SOC calculation
|
|
bat->ocv_empty = num_cells * 3.0; // because of flat OCV of LFP cells...
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
|
|
|
bat->trickle_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0.0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NMC:
|
|
case BAT_TYPE_NMC_HV:
|
|
bat->topping_voltage = num_cells * ((type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20);
|
|
bat->voltage_absolute_max = bat->topping_voltage + num_cells * 0.05;
|
|
bat->voltage_recharge = num_cells * 3.9;
|
|
|
|
bat->voltage_load_disconnect = num_cells * 3.3;
|
|
bat->voltage_load_reconnect = num_cells * 3.6;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX;
|
|
|
|
bat->voltage_absolute_min = num_cells * 2.5;
|
|
|
|
bat->ocv_full = num_cells * 4.0;
|
|
bat->ocv_empty = num_cells * 3.0;
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
|
|
|
bat->trickle_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0.0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NONE:
|
|
break;
|
|
}
|
|
}
|
|
|
|
// checks settings in bat_conf for plausibility
|
|
bool battery_conf_check(BatConf *bat_conf)
|
|
{
|
|
// things to check:
|
|
// - load_disconnect/reconnect hysteresis makes sense?
|
|
// - cutoff current not extremely low/high
|
|
// - capacity plausible
|
|
|
|
/*
|
|
printf("battery_conf_check: %d %d %d %d %d %d %d\n",
|
|
bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.6),
|
|
bat_conf->voltage_recharge < (bat_conf->voltage_max - 0.4),
|
|
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1),
|
|
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4),
|
|
bat_conf->current_cutoff_CV < (bat_conf->nominal_capacity / 10.0), // C/10 or lower allowed
|
|
bat_conf->current_cutoff_CV > 0.01,
|
|
(bat_conf->trickle_enabled == false ||
|
|
(bat_conf->trickle_voltage < bat_conf->voltage_max &&
|
|
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
|
|
);
|
|
*/
|
|
|
|
return
|
|
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
|
|
bat_conf->voltage_recharge < (bat_conf->topping_voltage - 0.4) &&
|
|
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
|
|
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&
|
|
// max. 10% drop
|
|
bat_conf->internal_resistance < bat_conf->voltage_load_disconnect * 0.1 / LOAD_CURRENT_MAX &&
|
|
// max. 3% loss
|
|
bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / LOAD_CURRENT_MAX &&
|
|
// C/10 or lower current cutoff allowed
|
|
bat_conf->topping_current_cutoff < (bat_conf->nominal_capacity / 10.0) &&
|
|
bat_conf->topping_current_cutoff > 0.01 &&
|
|
(bat_conf->trickle_enabled == false ||
|
|
(bat_conf->trickle_voltage < bat_conf->topping_voltage &&
|
|
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
|
|
);
|
|
}
|
|
|
|
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
|
|
{
|
|
// TODO: stop DC/DC
|
|
|
|
destination->topping_voltage = source->topping_voltage;
|
|
destination->voltage_recharge = source->voltage_recharge;
|
|
destination->voltage_load_reconnect = source->voltage_load_reconnect;
|
|
destination->voltage_load_disconnect = source->voltage_load_disconnect;
|
|
destination->voltage_absolute_max = source->voltage_absolute_max;
|
|
destination->voltage_absolute_min = source->voltage_absolute_min;
|
|
destination->charge_current_max = source->charge_current_max;
|
|
destination->topping_current_cutoff = source->topping_current_cutoff;
|
|
destination->topping_duration = source->topping_duration;
|
|
destination->trickle_enabled = source->trickle_enabled;
|
|
destination->trickle_voltage = source->trickle_voltage;
|
|
destination->trickle_recharge_time = source->trickle_recharge_time;
|
|
destination->charge_temp_max = source->charge_temp_max;
|
|
destination->charge_temp_min = source->charge_temp_min;
|
|
destination->discharge_temp_max = source->discharge_temp_max;
|
|
destination->discharge_temp_min = source->discharge_temp_min;
|
|
destination->temperature_compensation = source->temperature_compensation;
|
|
destination->internal_resistance = source->internal_resistance;
|
|
destination->wire_resistance = source->wire_resistance;
|
|
|
|
// reset Ah counter and SOH if battery nominal capacity was changed
|
|
if (destination->nominal_capacity != source->nominal_capacity) {
|
|
destination->nominal_capacity = source->nominal_capacity;
|
|
if (charger != NULL) {
|
|
charger->discharged_Ah = 0;
|
|
charger->usable_capacity = 0;
|
|
charger->soh = 0;
|
|
}
|
|
}
|
|
|
|
// TODO:
|
|
// - update also DC/DC etc. (now this function only works at system startup)
|
|
// - restart DC/DC
|
|
}
|
|
|
|
void Charger::detect_num_batteries(BatConf *bat)
|
|
{
|
|
if (port->voltage > bat->voltage_absolute_min * 2 &&
|
|
port->voltage < bat->voltage_absolute_max * 2) {
|
|
num_batteries = 2;
|
|
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
|
|
}
|
|
else {
|
|
printf("Detected single battery (%.2f V max)\n", bat->topping_voltage);
|
|
}
|
|
}
|
|
|
|
void Charger::update_soc(BatConf *bat_conf)
|
|
{
|
|
static int soc_filtered = 0; // SOC / 100 for better filtering
|
|
|
|
if (fabs(port->current) < 0.2) {
|
|
int soc_new = (int)((port->voltage - bat_conf->ocv_empty) /
|
|
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
|
|
|
|
if (soc_new > 500 && soc_filtered == 0) {
|
|
// bypass filter during initialization
|
|
soc_filtered = soc_new;
|
|
}
|
|
else {
|
|
// filtering to adjust SOC very slowly
|
|
soc_filtered += (soc_new - soc_filtered) / 100;
|
|
}
|
|
|
|
if (soc_filtered > 10000) {
|
|
soc_filtered = 10000;
|
|
}
|
|
else if (soc_filtered < 0) {
|
|
soc_filtered = 0;
|
|
}
|
|
soc = soc_filtered / 100;
|
|
}
|
|
|
|
discharged_Ah += -port->current / 3600.0; // charged current is positive: change sign
|
|
}
|
|
|
|
void Charger::enter_state(int next_state)
|
|
{
|
|
//printf("Enter State: %d\n", next_state);
|
|
time_state_changed = time(NULL);
|
|
state = next_state;
|
|
}
|
|
|
|
void Charger::discharge_control(BatConf *bat_conf)
|
|
{
|
|
// load output state is defined by battery negative current limit
|
|
if (port->neg_current_limit < 0) {
|
|
// discharging currently allowed. see if that's still valid:
|
|
if (port->voltage < num_batteries *
|
|
(bat_conf->voltage_load_disconnect - port->current * port->neg_droop_res))
|
|
{
|
|
// low state of charge
|
|
port->neg_current_limit = 0;
|
|
num_deep_discharges++;
|
|
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
|
|
|
if (usable_capacity < 0.1) {
|
|
// reset to measured value if discharged the first time
|
|
if (first_full_charge_reached) {
|
|
usable_capacity = discharged_Ah;
|
|
}
|
|
}
|
|
else {
|
|
// slowly adapt new measurements with low-pass filter
|
|
usable_capacity =
|
|
0.8 * usable_capacity +
|
|
0.2 * discharged_Ah;
|
|
}
|
|
|
|
// simple SOH estimation
|
|
soh = usable_capacity / bat_conf->nominal_capacity;
|
|
}
|
|
else if (bat_temperature > bat_conf->discharge_temp_max) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_DIS_OVERTEMP);
|
|
}
|
|
else if (bat_temperature < bat_conf->discharge_temp_min) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
}
|
|
else {
|
|
// discharging currently not allowed. should we allow it?
|
|
if (port->voltage >= num_batteries *
|
|
(bat_conf->voltage_load_reconnect - port->current * port->neg_droop_res)
|
|
&& bat_temperature < bat_conf->discharge_temp_max - 1
|
|
&& bat_temperature > bat_conf->discharge_temp_min + 1)
|
|
{
|
|
// discharge current is stored as absolute value in bat_conf, but defined
|
|
// as negative current for power port
|
|
port->neg_current_limit = -bat_conf->discharge_current_max;
|
|
|
|
// delete all discharge error flags
|
|
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_DIS_UNDERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
}
|
|
}
|
|
|
|
void Charger::charge_control(BatConf *bat_conf)
|
|
{
|
|
// check battery temperature for charging direction
|
|
if (bat_temperature > bat_conf->charge_temp_max) {
|
|
port->pos_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_CHG_OVERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
else if (bat_temperature < bat_conf->charge_temp_min) {
|
|
port->pos_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
|
|
if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) &&
|
|
port->voltage < (bat_conf->voltage_absolute_max - 0.5) * num_batteries)
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
|
}
|
|
|
|
// state machine
|
|
switch (state) {
|
|
case CHG_STATE_IDLE: {
|
|
if (port->voltage < bat_conf->voltage_recharge * num_batteries
|
|
&& (time(NULL) - time_state_changed) > bat_conf->time_limit_recharge
|
|
&& bat_temperature < bat_conf->charge_temp_max - 1
|
|
&& bat_temperature > bat_conf->charge_temp_min + 1)
|
|
{
|
|
port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
full = false;
|
|
dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_BULK: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
|
|
if (port->voltage > num_batteries *
|
|
(port->sink_voltage_max - port->current * port->pos_droop_res))
|
|
{
|
|
enter_state(CHG_STATE_TOPPING);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TOPPING: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
|
|
if (port->voltage >= num_batteries *
|
|
(port->sink_voltage_max - port->current * port->pos_droop_res))
|
|
{
|
|
time_voltage_limit_reached = time(NULL);
|
|
}
|
|
|
|
// cut-off limit reached because battery full (i.e. CV limit still
|
|
// reached by available solar power within last 2s) or CV period long enough?
|
|
if ((port->current < bat_conf->topping_current_cutoff &&
|
|
(time(NULL) - time_voltage_limit_reached) < 2)
|
|
|| (time(NULL) - time_state_changed) > bat_conf->topping_duration)
|
|
{
|
|
full = true;
|
|
num_full_charges++;
|
|
discharged_Ah = 0; // reset coulomb counter
|
|
first_full_charge_reached = true;
|
|
|
|
if (bat_conf->equalization_enabled && (
|
|
(time(NULL) - time_last_equalization) / (24*60*60)
|
|
>= bat_conf->equalization_trigger_days ||
|
|
num_deep_discharges - deep_dis_last_equalization
|
|
>= bat_conf->equalization_trigger_deep_cycles))
|
|
{
|
|
port->sink_voltage_max = bat_conf->equalization_voltage;
|
|
port->pos_current_limit = bat_conf->equalization_current_limit;
|
|
enter_state(CHG_STATE_EQUALIZATION);
|
|
}
|
|
else if (bat_conf->trickle_enabled) {
|
|
port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
enter_state(CHG_STATE_TRICKLE);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TRICKLE: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
|
|
if (port->voltage >= num_batteries *
|
|
(port->sink_voltage_max - port->current * port->pos_droop_res))
|
|
{
|
|
time_voltage_limit_reached = time(NULL);
|
|
}
|
|
|
|
if (time(NULL) - time_voltage_limit_reached > bat_conf->trickle_recharge_time)
|
|
{
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
full = false;
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
// assumption: trickle does not harm the battery --> never go back to idle
|
|
// (for Li-ion battery: disable trickle!)
|
|
break;
|
|
}
|
|
case CHG_STATE_EQUALIZATION: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->sink_voltage_max = num_batteries * (bat_conf->equalization_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
|
|
// current or time limit for equalization reached
|
|
if (time(NULL) - time_state_changed > bat_conf->equalization_duration)
|
|
{
|
|
// reset triggers
|
|
time_last_equalization = time(NULL);
|
|
deep_dis_last_equalization = num_deep_discharges;
|
|
|
|
discharged_Ah = 0; // reset coulomb counter again
|
|
|
|
if (bat_conf->trickle_enabled) {
|
|
port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25));
|
|
enter_state(CHG_STATE_TRICKLE);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
void battery_init_dc_bus(PowerPort *port, BatConf *bat, unsigned int num_batteries)
|
|
{
|
|
unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed
|
|
|
|
port->src_voltage_start = bat->voltage_load_reconnect * n;
|
|
port->src_voltage_stop = bat->voltage_load_disconnect * n;
|
|
port->neg_current_limit = -bat->discharge_current_max;
|
|
|
|
// negative sign for compensation of actual resistance
|
|
port->neg_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n;
|
|
|
|
port->sink_voltage_max = bat->topping_voltage * n;
|
|
port->sink_voltage_min = bat->voltage_absolute_min * n;
|
|
port->pos_current_limit = bat->charge_current_max;
|
|
|
|
// negative sign for compensation of actual resistance
|
|
port->pos_droop_res = -bat->wire_resistance * n;
|
|
}
|