* Copyright (c) 2016 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "bat_charger.h"
|
|
|
|
#include <zephyr.h>
|
|
|
|
#include <math.h> // for fabs function
|
|
#include <stdio.h>
|
|
|
|
#include "board.h"
|
|
#include "helper.h"
|
|
#include "device_status.h"
|
|
|
|
extern DeviceStatus dev_stat;
|
|
extern LoadOutput load;
|
|
|
|
// DISCHARGE_CURRENT_MAX used to estimate current-compensation of load disconnect voltage
|
|
#ifdef DT_OUTPUTS_LOAD_CURRENT_MAX
|
|
#define DISCHARGE_CURRENT_MAX DT_OUTPUTS_LOAD_CURRENT_MAX
|
|
#else
|
|
#define DISCHARGE_CURRENT_MAX DT_INST_0_DCDC_CURRENT_MAX
|
|
#endif
|
|
|
|
void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capacity)
|
|
{
|
|
bat->nominal_capacity = nominal_capacity;
|
|
|
|
// 1C should be safe for all batteries
|
|
bat->charge_current_max = bat->nominal_capacity;
|
|
bat->discharge_current_max = bat->nominal_capacity;
|
|
|
|
bat->time_limit_recharge = 60; // sec
|
|
bat->topping_duration = 120*60; // sec
|
|
|
|
bat->charge_temp_max = 50;
|
|
bat->charge_temp_min = -10;
|
|
bat->discharge_temp_max = 50;
|
|
bat->discharge_temp_min = -10;
|
|
|
|
switch (type)
|
|
{
|
|
case BAT_TYPE_FLOODED:
|
|
case BAT_TYPE_AGM:
|
|
case BAT_TYPE_GEL:
|
|
bat->voltage_absolute_max = num_cells * 2.45;
|
|
bat->topping_voltage = num_cells * 2.4;
|
|
bat->voltage_recharge = num_cells * 2.3;
|
|
|
|
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
|
|
bat->voltage_load_disconnect = num_cells * 1.95;
|
|
bat->voltage_load_reconnect = num_cells * 2.10;
|
|
|
|
// assumption: Battery selection matching charge controller
|
|
bat->internal_resistance = num_cells * (1.95 - 1.80) / DISCHARGE_CURRENT_MAX;
|
|
|
|
bat->voltage_absolute_min = num_cells * 1.6;
|
|
|
|
// Voltages during idle (no charging/discharging current)
|
|
bat->ocv_full = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.10 : 2.15);
|
|
bat->ocv_empty = num_cells * 1.90;
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->topping_current_cutoff = bat->nominal_capacity * 0.04; // 3-5 % of C/1
|
|
|
|
bat->trickle_enabled = true;
|
|
bat->trickle_recharge_time = 30*60;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->trickle_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3);
|
|
|
|
// Enable for flooded batteries only, according to
|
|
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
|
|
bat->equalization_enabled = false;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->equalization_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45);
|
|
bat->equalization_duration = 60*60;
|
|
bat->equalization_current_limit = (1.0 / 7.0) * bat->nominal_capacity;
|
|
bat->equalization_trigger_days = 60;
|
|
bat->equalization_trigger_deep_cycles = 10;
|
|
|
|
bat->temperature_compensation = -0.003; // -3 mV/°C/cell
|
|
break;
|
|
|
|
case BAT_TYPE_LFP:
|
|
bat->voltage_absolute_max = num_cells * 3.60;
|
|
bat->topping_voltage = num_cells * 3.55; // CV voltage
|
|
bat->voltage_recharge = num_cells * 3.35;
|
|
|
|
bat->voltage_load_disconnect = num_cells * 3.0;
|
|
bat->voltage_load_reconnect = num_cells * 3.15;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / DISCHARGE_CURRENT_MAX;
|
|
bat->voltage_absolute_min = num_cells * 2.0;
|
|
|
|
bat->ocv_full = num_cells * 3.4; // will give really nonlinear SOC calculation
|
|
bat->ocv_empty = num_cells * 3.0; // because of flat OCV of LFP cells...
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
|
|
|
bat->trickle_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0.0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NMC:
|
|
case BAT_TYPE_NMC_HV:
|
|
bat->topping_voltage = num_cells * ((type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20);
|
|
bat->voltage_absolute_max = bat->topping_voltage + num_cells * 0.05;
|
|
bat->voltage_recharge = num_cells * 3.9;
|
|
|
|
bat->voltage_load_disconnect = num_cells * 3.3;
|
|
bat->voltage_load_reconnect = num_cells * 3.6;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / DISCHARGE_CURRENT_MAX;
|
|
|
|
bat->voltage_absolute_min = num_cells * 2.5;
|
|
|
|
bat->ocv_full = num_cells * 4.0;
|
|
bat->ocv_empty = num_cells * 3.0;
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_current_cutoff = bat->nominal_capacity / 10;
|
|
|
|
bat->trickle_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0.0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NONE:
|
|
break;
|
|
}
|
|
}
|
|
|
|
// checks settings in bat_conf for plausibility
|
|
bool battery_conf_check(BatConf *bat_conf)
|
|
{
|
|
// things to check:
|
|
// - load_disconnect/reconnect hysteresis makes sense?
|
|
// - cutoff current not extremely low/high
|
|
// - capacity plausible
|
|
|
|
/*
|
|
printf("battery_conf_check: %d %d %d %d %d %d %d\n",
|
|
bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.6),
|
|
bat_conf->voltage_recharge < (bat_conf->voltage_max - 0.4),
|
|
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1),
|
|
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4),
|
|
bat_conf->current_cutoff_CV < (bat_conf->nominal_capacity / 10.0), // C/10 or lower allowed
|
|
bat_conf->current_cutoff_CV > 0.01,
|
|
(bat_conf->trickle_enabled == false ||
|
|
(bat_conf->trickle_voltage < bat_conf->voltage_max &&
|
|
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
|
|
);
|
|
*/
|
|
|
|
return
|
|
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
|
|
bat_conf->voltage_recharge < (bat_conf->topping_voltage - 0.4) &&
|
|
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
|
|
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&
|
|
// max. 10% drop
|
|
bat_conf->internal_resistance < bat_conf->voltage_load_disconnect * 0.1 /
|
|
DISCHARGE_CURRENT_MAX &&
|
|
// max. 3% loss
|
|
bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX &&
|
|
// C/10 or lower current cutoff allowed
|
|
bat_conf->topping_current_cutoff < (bat_conf->nominal_capacity / 10.0) &&
|
|
bat_conf->topping_current_cutoff > 0.01 &&
|
|
(bat_conf->trickle_enabled == false ||
|
|
(bat_conf->trickle_voltage < bat_conf->topping_voltage &&
|
|
bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect))
|
|
);
|
|
}
|
|
|
|
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
|
|
{
|
|
// TODO: stop DC/DC
|
|
|
|
destination->topping_voltage = source->topping_voltage;
|
|
destination->voltage_recharge = source->voltage_recharge;
|
|
destination->voltage_load_reconnect = source->voltage_load_reconnect;
|
|
destination->voltage_load_disconnect = source->voltage_load_disconnect;
|
|
destination->voltage_absolute_max = source->voltage_absolute_max;
|
|
destination->voltage_absolute_min = source->voltage_absolute_min;
|
|
destination->charge_current_max = source->charge_current_max;
|
|
destination->topping_current_cutoff = source->topping_current_cutoff;
|
|
destination->topping_duration = source->topping_duration;
|
|
destination->trickle_enabled = source->trickle_enabled;
|
|
destination->trickle_voltage = source->trickle_voltage;
|
|
destination->trickle_recharge_time = source->trickle_recharge_time;
|
|
destination->charge_temp_max = source->charge_temp_max;
|
|
destination->charge_temp_min = source->charge_temp_min;
|
|
destination->discharge_temp_max = source->discharge_temp_max;
|
|
destination->discharge_temp_min = source->discharge_temp_min;
|
|
destination->temperature_compensation = source->temperature_compensation;
|
|
destination->internal_resistance = source->internal_resistance;
|
|
destination->wire_resistance = source->wire_resistance;
|
|
|
|
// reset Ah counter and SOH if battery nominal capacity was changed
|
|
if (destination->nominal_capacity != source->nominal_capacity) {
|
|
destination->nominal_capacity = source->nominal_capacity;
|
|
if (charger != NULL) {
|
|
charger->discharged_Ah = 0;
|
|
charger->usable_capacity = 0;
|
|
charger->soh = 0;
|
|
}
|
|
}
|
|
|
|
// TODO:
|
|
// - update also DC/DC etc. (now this function only works at system startup)
|
|
// - restart DC/DC
|
|
}
|
|
|
|
bool battery_conf_changed(BatConf *a, BatConf *b)
|
|
{
|
|
if (
|
|
a->topping_voltage != b->topping_voltage ||
|
|
a->voltage_recharge != b->voltage_recharge ||
|
|
a->voltage_load_reconnect != b->voltage_load_reconnect ||
|
|
a->voltage_load_disconnect != b->voltage_load_disconnect ||
|
|
a->voltage_absolute_max != b->voltage_absolute_max ||
|
|
a->voltage_absolute_min != b->voltage_absolute_min ||
|
|
a->charge_current_max != b->charge_current_max ||
|
|
a->topping_current_cutoff != b->topping_current_cutoff ||
|
|
a->topping_duration != b->topping_duration ||
|
|
a->trickle_enabled != b->trickle_enabled ||
|
|
a->trickle_voltage != b->trickle_voltage ||
|
|
a->trickle_recharge_time != b->trickle_recharge_time ||
|
|
a->charge_temp_max != b->charge_temp_max ||
|
|
a->charge_temp_min != b->charge_temp_min ||
|
|
a->discharge_temp_max != b->discharge_temp_max ||
|
|
a->discharge_temp_min != b->discharge_temp_min ||
|
|
a->temperature_compensation != b->temperature_compensation ||
|
|
a->internal_resistance != b->internal_resistance ||
|
|
a->wire_resistance != b->wire_resistance
|
|
) {
|
|
return true;
|
|
}
|
|
else {
|
|
return false;
|
|
}
|
|
}
|
|
|
|
void Charger::detect_num_batteries(BatConf *bat)
|
|
{
|
|
if (port->bus->voltage > bat->voltage_absolute_min * 2 &&
|
|
port->bus->voltage < bat->voltage_absolute_max * 2)
|
|
{
|
|
port->bus->series_multiplier = 2;
|
|
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
|
|
}
|
|
else {
|
|
printf("Detected single battery (%.2f V max)\n", bat->topping_voltage);
|
|
}
|
|
}
|
|
|
|
void Charger::update_soc(BatConf *bat_conf)
|
|
{
|
|
static int soc_filtered = 0; // SOC / 100 for better filtering
|
|
|
|
if (fabs(port->current) < 0.2) {
|
|
int soc_new = (int)((port->bus->voltage - bat_conf->ocv_empty) /
|
|
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
|
|
|
|
if (soc_new > 500 && soc_filtered == 0) {
|
|
// bypass filter during initialization
|
|
soc_filtered = soc_new;
|
|
}
|
|
else {
|
|
// filtering to adjust SOC very slowly
|
|
soc_filtered += (soc_new - soc_filtered) / 100;
|
|
}
|
|
|
|
if (soc_filtered > 10000) {
|
|
soc_filtered = 10000;
|
|
}
|
|
else if (soc_filtered < 0) {
|
|
soc_filtered = 0;
|
|
}
|
|
soc = soc_filtered / 100;
|
|
}
|
|
|
|
discharged_Ah += -port->current / 3600.0; // charged current is positive: change sign
|
|
}
|
|
|
|
void Charger::enter_state(int next_state)
|
|
{
|
|
//printf("Enter State: %d\n", next_state);
|
|
time_state_changed = uptime();
|
|
state = next_state;
|
|
}
|
|
|
|
void Charger::discharge_control(BatConf *bat_conf)
|
|
{
|
|
#if DT_OUTPUTS_LOAD_PRESENT || DT_OUTPUTS_USB_PWR_PRESENT
|
|
if (!empty) {
|
|
// as we don't have a proper SOC estimation, we determine an empty battery by the main
|
|
// load output being switched off
|
|
if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
|
empty = true;
|
|
num_deep_discharges++;
|
|
|
|
if (usable_capacity == 0.0F) {
|
|
// reset to measured value if discharged the first time
|
|
usable_capacity = discharged_Ah;
|
|
}
|
|
else {
|
|
// slowly adapt new measurements with low-pass filter
|
|
usable_capacity =
|
|
0.8 * usable_capacity +
|
|
0.2 * discharged_Ah;
|
|
}
|
|
|
|
// simple SOH estimation
|
|
soh = usable_capacity / bat_conf->nominal_capacity;
|
|
}
|
|
}
|
|
else {
|
|
if (!flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
|
empty = false;
|
|
}
|
|
}
|
|
|
|
// negative current limit = allowed battery discharge current
|
|
if (port->neg_current_limit < 0) {
|
|
|
|
// This limit should normally never be reached, as the load output settings should be
|
|
// higher. The flag can be used to trigger actions of last resort, e.g. deep-sleep
|
|
// of the charge controller itself.
|
|
if (port->bus->voltage < port->bus->src_control_voltage(bat_conf->voltage_absolute_min)) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
|
|
if (bat_temperature > bat_conf->discharge_temp_max) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_DIS_OVERTEMP);
|
|
}
|
|
else if (bat_temperature < bat_conf->discharge_temp_min) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
}
|
|
else {
|
|
// discharging currently not allowed. should we allow it?
|
|
|
|
if (port->bus->voltage >=
|
|
port->bus->src_control_voltage(bat_conf->voltage_absolute_min + 0.1))
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
|
|
if (bat_temperature < bat_conf->discharge_temp_max - 1 &&
|
|
bat_temperature > bat_conf->discharge_temp_min + 1)
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
|
|
if (!dev_stat.has_error(
|
|
ERR_BAT_UNDERVOLTAGE | ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP))
|
|
{
|
|
// discharge current is stored as absolute value in bat_conf, but defined
|
|
// as negative current for power port
|
|
port->neg_current_limit = -bat_conf->discharge_current_max;
|
|
|
|
}
|
|
}
|
|
#endif // DT_OUTPUTS_LOAD_PRESENT || DT_OUTPUTS_USB_PWR_PRESENT
|
|
}
|
|
|
|
void Charger::charge_control(BatConf *bat_conf)
|
|
{
|
|
// check battery temperature for charging direction
|
|
if (bat_temperature > bat_conf->charge_temp_max) {
|
|
port->pos_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_CHG_OVERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
else if (bat_temperature < bat_conf->charge_temp_min) {
|
|
port->pos_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
|
|
if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) &&
|
|
port->bus->voltage < (bat_conf->voltage_absolute_max - 0.5) * port->bus->series_multiplier)
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
|
}
|
|
|
|
// state machine
|
|
switch (state) {
|
|
case CHG_STATE_IDLE: {
|
|
if (port->bus->voltage < port->bus->sink_control_voltage(bat_conf->voltage_recharge)
|
|
&& port->bus->voltage > port->bus->sink_control_voltage(bat_conf->voltage_absolute_min) // ToDo set error flag otherwise
|
|
&& (uptime() - time_state_changed) > bat_conf->time_limit_recharge
|
|
&& bat_temperature < bat_conf->charge_temp_max - 1
|
|
&& bat_temperature > bat_conf->charge_temp_min + 1)
|
|
{
|
|
port->bus->sink_voltage_bound = bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
full = false;
|
|
dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_BULK: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_bound = bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
if (port->bus->voltage > port->bus->sink_control_voltage()) {
|
|
target_voltage_timer = 0;
|
|
enter_state(CHG_STATE_TOPPING);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TOPPING: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_bound = bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
if (port->bus->voltage >= port->bus->sink_control_voltage() - 0.05F) {
|
|
// battery is full if topping target voltage is still reached (i.e. sufficient
|
|
// solar power available) and time limit or cut-off current reached
|
|
if (port->current < bat_conf->topping_current_cutoff ||
|
|
target_voltage_timer > bat_conf->topping_duration)
|
|
{
|
|
full = true;
|
|
}
|
|
target_voltage_timer++;
|
|
}
|
|
else if (uptime() - time_state_changed > 8 * 60 * 60) {
|
|
// in topping phase already for 8 hours (i.e. not enough solar power available)
|
|
// --> go back to bulk charging for the next day
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
|
|
if (full) {
|
|
num_full_charges++;
|
|
discharged_Ah = 0; // reset coulomb counter
|
|
|
|
if (bat_conf->equalization_enabled && (
|
|
(uptime() - time_last_equalization) / (24*60*60)
|
|
>= bat_conf->equalization_trigger_days ||
|
|
num_deep_discharges - deep_dis_last_equalization
|
|
>= bat_conf->equalization_trigger_deep_cycles))
|
|
{
|
|
port->bus->sink_voltage_bound = bat_conf->equalization_voltage;
|
|
port->pos_current_limit = bat_conf->equalization_current_limit;
|
|
enter_state(CHG_STATE_EQUALIZATION);
|
|
}
|
|
else if (bat_conf->trickle_enabled) {
|
|
port->bus->sink_voltage_bound = bat_conf->trickle_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
enter_state(CHG_STATE_TRICKLE);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TRICKLE: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_bound = bat_conf->trickle_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
if (port->bus->voltage >= port->bus->sink_control_voltage()) {
|
|
time_target_voltage_reached = uptime();
|
|
}
|
|
|
|
if (uptime() - time_target_voltage_reached > bat_conf->trickle_recharge_time)
|
|
{
|
|
// the battery was discharged: trickle voltage could not be reached anymore
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
full = false;
|
|
// assumption: trickle does not harm the battery --> never go back to idle
|
|
// (for Li-ion battery: disable trickle!)
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_EQUALIZATION: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_bound = bat_conf->equalization_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
// current or time limit for equalization reached
|
|
if (uptime() - time_state_changed > bat_conf->equalization_duration)
|
|
{
|
|
// reset triggers
|
|
time_last_equalization = uptime();
|
|
deep_dis_last_equalization = num_deep_discharges;
|
|
|
|
discharged_Ah = 0; // reset coulomb counter again
|
|
|
|
if (bat_conf->trickle_enabled) {
|
|
port->bus->sink_voltage_bound = bat_conf->trickle_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
enter_state(CHG_STATE_TRICKLE);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
void Charger::init_terminal(BatConf *bat)
|
|
{
|
|
port->bus->sink_voltage_bound = bat->topping_voltage;
|
|
port->bus->src_voltage_bound = bat->voltage_load_disconnect;
|
|
|
|
port->neg_current_limit = -bat->discharge_current_max;
|
|
port->pos_current_limit = bat->charge_current_max;
|
|
|
|
/*
|
|
* Negative sign for compensation of actual resistance
|
|
*
|
|
* droop_res is multiplied with number of series connected batteries to calculate control
|
|
* voltage, so we need to divide by number of batteries here for correction
|
|
*/
|
|
port->bus->sink_droop_res = -bat->wire_resistance / port->bus->series_multiplier;
|
|
|
|
/*
|
|
* In discharging direction also include battery internal resistance for current-compensation
|
|
* of voltage setpoints
|
|
*/
|
|
port->bus->src_droop_res = -bat->wire_resistance / port->bus->series_multiplier
|
|
- bat->internal_resistance;
|
|
}
|