For PWM charge controllers, the topping stage was sometimes very short
and the battery did not get fully charged.
This commit adds a voltage_filtered and current_filtered member variable
to DcBus and PowerPort classes which can hold measurements more heavily
filtered (initial time constant setting: 10 seconds). This should fix
above issues with the charging algorithm.
This allows us to enable e.g debug output for the CAN module with
CONFIG_CAN_LOG_LEVEL=4 without enabling the global
CONFIG_LOG_DEFAULT_LEVEL=4 and being swamped with debug output from
all of Zephyr's subsytems.
This makes more sense because the DC/DC converter actually connects two
DcBuses and does not need separate PowerPorts. Also makes the code look
more clean as variable access like dcdc.hvs->bus->voltage is avoided.
The DcBus pointers in the Dcdc are now called hvb and lvb for high-
voltage side bus and low-voltage side bus.
Using 16-bit for calculation allows to increase resolution by oversampling.
The ADC was already configured to use left-aligned 12-bit readings, which can
be treated the same as 16-bit native readings.
A Kconfig CUSTOM_DCDC_CONTROLLER is introduced to enable implementation of
more sophisticated control functions than the standard perturb and observe.
A function dcdc_low_level_controller() must be implemented and is called
from the DMA interrupt after each new current sensor reading.
The default Dcdc::control() function is defined __weak.
Identified issues:
- The load output and USB charging port shared the same state machine,
which did not allow to set different switch-off thresholds.
- Load error codes were global, so it was not possible to have multiple
load instances.
This commit introduces load-specific error_flags, makes the LoadOutput
class inherit from PowerPort (to improve code readability), separates
the load driver better from higher level implementation and adds a
second LoadOutput object for the USB charging port.
First step of unifying different ports connected to one bus. At a later
step, also the load and charger classes should inherit from PowerPort
class to make overall charge controller structure more clean.
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.