DAQ: Add high-side overvoltage alert limit
Also rename the functions which set the alert limits to set_xx_limit instead of set_xx_alert.
This commit is contained in:
+37
-12
@@ -249,7 +249,7 @@ void daq_update()
|
||||
// else: keep previous setting
|
||||
}
|
||||
|
||||
void high_voltage_alert()
|
||||
void lv_overvoltage_alert()
|
||||
{
|
||||
// disable any sort of input
|
||||
#if DT_NODE_EXISTS(DT_PATH(dcdc))
|
||||
@@ -263,21 +263,36 @@ void high_voltage_alert()
|
||||
|
||||
dev_stat.set_error(ERR_BAT_OVERVOLTAGE);
|
||||
|
||||
LOG_ERR("High voltage alert, ADC reading: %d limit: %d\n",
|
||||
LOG_ERR("Low-side overvoltage alert, ADC reading: %d limit: %d\n",
|
||||
adc_readings[ADC_POS(v_low)], adc_alerts_upper[ADC_POS(v_low)].limit);
|
||||
}
|
||||
|
||||
void low_voltage_alert()
|
||||
void lv_undervoltage_alert()
|
||||
{
|
||||
#if DT_NODE_EXISTS(DT_CHILD(DT_PATH(outputs), load))
|
||||
// the battery undervoltage must have been caused by a load current peak
|
||||
load.stop(ERR_LOAD_VOLTAGE_DIP);
|
||||
#endif
|
||||
|
||||
LOG_ERR("Low voltage alert, ADC reading: %d limit: %d\n",
|
||||
LOG_ERR("Low-side undervoltage alert, ADC reading: %d limit: %d\n",
|
||||
adc_readings[ADC_POS(v_low)], adc_alerts_lower[ADC_POS(v_low)].limit);
|
||||
}
|
||||
|
||||
#if DT_NODE_EXISTS(DT_PATH(dcdc))
|
||||
void hv_overvoltage_alert()
|
||||
{
|
||||
dcdc.stop();
|
||||
|
||||
// do not use enter_state function, as we don't want to wait entire recharge delay
|
||||
charger.state = CHG_STATE_IDLE;
|
||||
|
||||
dev_stat.set_error(ERR_DCDC_HS_OVERVOLTAGE);
|
||||
|
||||
LOG_ERR("High-side overvoltage alert, ADC reading: %d limit: %d\n",
|
||||
adc_readings[ADC_POS(v_high)], adc_alerts_upper[ADC_POS(v_high)].limit);
|
||||
}
|
||||
#endif
|
||||
|
||||
void adc_upper_alert_inhibit(int adc_pos, int timeout_ms)
|
||||
{
|
||||
// set negative value so that we get a final debouncing of this timeout + the original
|
||||
@@ -285,7 +300,7 @@ void adc_upper_alert_inhibit(int adc_pos, int timeout_ms)
|
||||
adc_alerts_upper[adc_pos].debounce_ms = -timeout_ms;
|
||||
}
|
||||
|
||||
uint16_t adc_get_alert_limit(float scale, float limit)
|
||||
uint16_t adc_raw_clamp(float scale, float limit)
|
||||
{
|
||||
// even if we have a higher voltage limit, we must limit it
|
||||
// to the max value the ADC will be able to deliver
|
||||
@@ -293,20 +308,30 @@ uint16_t adc_get_alert_limit(float scale, float limit)
|
||||
return limit_scaled > (float)UINT16_MAX ? UINT16_MAX : (uint16_t)(limit_scaled);
|
||||
}
|
||||
|
||||
void daq_set_lv_alerts(float upper, float lower)
|
||||
void daq_set_lv_limits(float lv_overvoltage, float lv_undervoltage)
|
||||
{
|
||||
int vref = VREF;
|
||||
float scale = (((4096 << 4) * 1000) / ADC_GAIN(v_low)) / vref;
|
||||
float scale = (((4096 << 4) * 1000) / ADC_GAIN(v_low)) / (float)VREF;
|
||||
|
||||
// LV side (battery) overvoltage alert
|
||||
adc_alerts_upper[ADC_POS(v_low)].limit = adc_get_alert_limit(scale, upper);
|
||||
adc_alerts_upper[ADC_POS(v_low)].callback = high_voltage_alert;
|
||||
adc_alerts_upper[ADC_POS(v_low)].limit = adc_raw_clamp(scale, lv_overvoltage);
|
||||
adc_alerts_upper[ADC_POS(v_low)].callback = lv_overvoltage_alert;
|
||||
|
||||
// LV side (battery) undervoltage alert
|
||||
adc_alerts_lower[ADC_POS(v_low)].limit = adc_get_alert_limit(scale, lower);
|
||||
adc_alerts_lower[ADC_POS(v_low)].callback = low_voltage_alert;
|
||||
adc_alerts_lower[ADC_POS(v_low)].limit = adc_raw_clamp(scale, lv_undervoltage);
|
||||
adc_alerts_lower[ADC_POS(v_low)].callback = lv_undervoltage_alert;
|
||||
}
|
||||
|
||||
#if DT_NODE_EXISTS(DT_PATH(dcdc))
|
||||
void daq_set_hv_limit(float hv_overvoltage)
|
||||
{
|
||||
float scale = (((4096 << 4) * 1000) / ADC_GAIN(v_high)) / (float)VREF;
|
||||
|
||||
// HV side (solar/grid) overvoltage alert
|
||||
adc_alerts_upper[ADC_POS(v_high)].limit = adc_raw_clamp(scale, hv_overvoltage);
|
||||
adc_alerts_upper[ADC_POS(v_high)].callback = hv_overvoltage_alert;
|
||||
}
|
||||
#endif
|
||||
|
||||
#if defined(UNIT_TEST)
|
||||
|
||||
#include "../test/daq_stub.h"
|
||||
|
||||
@@ -126,10 +126,17 @@ void adc_update_value(unsigned int pos);
|
||||
/**
|
||||
* Set lv side (battery) voltage limits where an alert should be triggered
|
||||
*
|
||||
* @param upper Upper voltage limit
|
||||
* @param lower Lower voltage limit
|
||||
* @param lv_overvoltage Upper voltage limit
|
||||
* @param lv_undervoltage Lower voltage limit
|
||||
*/
|
||||
void daq_set_lv_alerts(float upper, float lower);
|
||||
void daq_set_lv_limits(float lv_overvoltage, float lv_undervoltage);
|
||||
|
||||
/**
|
||||
* Set hv side (grid/solar) voltage limit where an alert should be triggered
|
||||
*
|
||||
* @param hv_overvoltage Upper voltage limit
|
||||
*/
|
||||
void daq_set_hv_limit(float hv_overvoltage);
|
||||
|
||||
/**
|
||||
* Add an inhibit delay to the alerts to disable it temporarily
|
||||
|
||||
@@ -89,6 +89,12 @@ enum ErrorFlag {
|
||||
*/
|
||||
ERR_DCDC_HS_MOSFET_SHORT = 1U << 14,
|
||||
|
||||
/** Short-circuit in HS MOSFET
|
||||
*
|
||||
* Set in Dcdc::control() and never cleared
|
||||
*/
|
||||
ERR_DCDC_HS_OVERVOLTAGE = 1U << 15,
|
||||
|
||||
/** Mask to catch all error flags (up to 32 errors)
|
||||
*/
|
||||
ERR_ANY_ERROR = UINT32_MAX,
|
||||
|
||||
+5
-1
@@ -44,6 +44,10 @@ void main(void)
|
||||
// Data Acquisition (DAQ) setup
|
||||
daq_setup();
|
||||
|
||||
#if DT_NODE_EXISTS(DT_PATH(dcdc))
|
||||
daq_set_hv_limit(DT_PROP(DT_PATH(pcb), hs_voltage_max));
|
||||
#endif
|
||||
|
||||
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
|
||||
solar_terminal.init_solar();
|
||||
#endif
|
||||
@@ -138,7 +142,7 @@ void control_thread()
|
||||
daq_update();
|
||||
|
||||
// alerts should trigger only for transients, so update based on actual voltage
|
||||
daq_set_lv_alerts(lv_terminal.bus->voltage * 1.2F, lv_terminal.bus->voltage * 0.8F);
|
||||
daq_set_lv_limits(lv_terminal.bus->voltage * 1.2F, lv_terminal.bus->voltage * 0.8F);
|
||||
|
||||
lv_terminal.update_bus_current_margins();
|
||||
|
||||
|
||||
+1
-1
@@ -23,6 +23,6 @@ void prepare_adc_readings(AdcValues values);
|
||||
void prepare_adc_filtered();
|
||||
void clear_adc_filtered();
|
||||
uint32_t get_adc_filtered(uint32_t channel);
|
||||
uint16_t adc_get_alert_limit(float scale, float limit);
|
||||
uint16_t adc_raw_clamp(float scale, float limit);
|
||||
|
||||
#endif
|
||||
|
||||
@@ -40,8 +40,8 @@
|
||||
#define DT_N_S_adc_inputs_S_temp_bat_P_divider 1
|
||||
#define DT_N_S_adc_inputs_S_temp_bat_P_filter_const 5
|
||||
|
||||
#define DT_N_S_adc_inputs_S_v_high_P_multiplier 105600
|
||||
#define DT_N_S_adc_inputs_S_v_high_P_divider 5600
|
||||
#define DT_N_S_adc_inputs_S_v_high_P_multiplier 102800
|
||||
#define DT_N_S_adc_inputs_S_v_high_P_divider 2800
|
||||
#define DT_N_S_adc_inputs_S_v_high_P_filter_const 5
|
||||
|
||||
#define DT_N_S_adc_inputs_S_v_low_P_multiplier 105600
|
||||
|
||||
+25
-7
@@ -97,11 +97,11 @@ void check_temperature_readings()
|
||||
TEST_ASSERT_EQUAL_FLOAT(adcval.bat_temperature, round(charger.bat_temperature * 10) / 10);
|
||||
}
|
||||
|
||||
void adc_alert_undervoltage_triggering()
|
||||
void adc_alert_lv_undervoltage_triggering()
|
||||
{
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
|
||||
daq_set_lv_alerts(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
|
||||
daq_set_lv_limits(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
|
||||
prepare_adc_filtered();
|
||||
adc_update_value(ADC_POS(v_low));
|
||||
|
||||
@@ -125,11 +125,11 @@ void adc_alert_undervoltage_triggering()
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_UNDERVOLTAGE)); // ToDo
|
||||
}
|
||||
|
||||
void adc_alert_overvoltage_triggering()
|
||||
void adc_alert_lv_overvoltage_triggering()
|
||||
{
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
|
||||
daq_set_lv_alerts(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
|
||||
daq_set_lv_limits(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
|
||||
prepare_adc_filtered();
|
||||
adc_update_value(ADC_POS(v_low));
|
||||
|
||||
@@ -156,10 +156,27 @@ void adc_alert_overvoltage_triggering()
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE));
|
||||
}
|
||||
|
||||
void adc_alert_hv_overvoltage_triggering()
|
||||
{
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
daq_set_hv_limit(DT_PROP(DT_PATH(pcb), hs_voltage_max));
|
||||
prepare_adc_filtered();
|
||||
adc_update_value(ADC_POS(v_high));
|
||||
|
||||
// overvoltage test
|
||||
adcval.solar_voltage = 85.0F;
|
||||
prepare_adc_readings(adcval);
|
||||
adc_update_value(ADC_POS(v_high));
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE));
|
||||
adc_update_value(ADC_POS(v_high));
|
||||
TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE));
|
||||
TEST_ASSERT_EQUAL(DCDC_CONTROL_OFF, dcdc.state);
|
||||
}
|
||||
|
||||
void adc_alert_overflow_prevention()
|
||||
{
|
||||
// try to set an alert that overflows the 12-bit ADC resolution
|
||||
uint16_t limit = adc_get_alert_limit(1, UINT16_MAX + 1);
|
||||
uint16_t limit = adc_raw_clamp(1, UINT16_MAX + 1);
|
||||
TEST_ASSERT_EQUAL_HEX(UINT16_MAX, limit);
|
||||
}
|
||||
|
||||
@@ -195,8 +212,9 @@ void daq_tests()
|
||||
|
||||
//RUN_TEST(check_temperature_readings); // TODO
|
||||
|
||||
RUN_TEST(adc_alert_undervoltage_triggering);
|
||||
RUN_TEST(adc_alert_overvoltage_triggering);
|
||||
RUN_TEST(adc_alert_lv_undervoltage_triggering);
|
||||
RUN_TEST(adc_alert_lv_overvoltage_triggering);
|
||||
RUN_TEST(adc_alert_hv_overvoltage_triggering);
|
||||
RUN_TEST(adc_alert_overflow_prevention);
|
||||
|
||||
UNITY_END();
|
||||
|
||||
Reference in New Issue
Block a user