Commit Graph
167 Commits
Author SHA1 Message Date
hogthrob a600bf8a09 OLED display brightness adjust, reset improvement, SOC display and more (#75)
- OLED brightness can be set to extend life
- OLED display correctly initialized at MCU restart even without power off
  Sometimes the OLED display displays all content shifted if the MCU is
  reset without cutting the power to the display (i.e. without display reset).
- SOC is display in battery symbol showing 0 to 5 bars
- Internal temperature is displayed if no external sensor is detected (t)
- PWM value displays as "OFF" if the PWM/halfbridge is not active
2019-11-09 08:22:28 +01:00
Martin Jaeger c26c17221a Overvoltage alert improved for PWM switching
Previously, the alert was sometimes erroneously triggered in PWM charger
absorption phase (constant voltage, PWM switching). Now the overvoltage
alert is inhibited during turn-on in each PWM cycle by an interrupt.
2019-11-08 13:06:17 +01:00
hogthrob 71fd6519bc Fix for ADC randomly misconfigured (#74)
This issue happened because the HAL ADC configuration data structure
is allocated on the stack (which by default is not initialized,
i.e. contains potentially non-zero data). As most of this structure was
explicitly initialized only sometimes the OversampleMode setting was
not 0, in this case the ADC had no left data alignment, i.e. delivered
too low values. If it happens, the system sees very weird temperature 
and voltage/power values.
2019-11-08 07:29:04 +01:00
Martin Jaeger 328215dc8e Load overvoltage detection corrected and error flag comments added 2019-11-07 16:00:51 +01:00
Martin Jaeger 4c5401d562 PWM switch max current limit control fixed 2019-11-06 10:49:40 +01:00
Martin Jaeger 2992cebb81 Fixed internal temperature data output 2019-11-06 10:17:49 +01:00
Martin Jäger b0fe567884 Merge pull request #73 from LibreSolar/adc-alerts
ADC alerts for faster over/undervoltage detection
2019-11-06 10:10:31 +01:00
Martin Jaeger 5e3181f5e5 Distinguishing between OV and UV alerts, inhibit added
- During overvoltage alerts, only power sources (PWM switch and DC/DC are
  switched off), undervoltage only switches load off
- Alert inhibit added to prevent switching off during PWM switch startup
2019-11-05 18:43:33 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
Martin Jaeger 7412b11002 ADC filtering in separate function + unit-tests 2019-11-04 18:02:43 +01:00
hogthrob bc8f74aa45 Multiple UExt objects at same time (#68)
The change permits use of multiple UExt objects at the same time,
given that these use different pins.
The current UExt code is safe to be used in combination
(OLED display and ESP32 wifi).
Future extension may require some checks to be put in place to
ensure correct configuration.
Could be achieved using preprocessor macros easily.

Uses same objectification concept we used for the ThingSet devices.
Could be merged into one if desired.
2019-11-04 09:23:37 +01:00
hogthrob bec02cb25b Switched to use power of 2 error numbers (#72)
In addition to the normal error flags we now have
ERR_ANY_ERROR which may be used to clear all errors
at once or to use in has_error to see if there is any error flag set.
2019-11-04 09:19:06 +01:00
hogthrob fd474e5350 Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code
completion), no performance loss due to inlining.
2019-11-02 08:22:00 +01:00
Martin Jaeger b09f4ca809 More error flags added and defined as output data object 2019-11-01 12:58:31 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00
Martin Jaeger af4af04697 Fix initialization of load.voltage_prev 2019-11-01 08:53:51 +01:00
Martin Jaeger b974e3c1ba PWM 2420 PCB conf updated after testing 2019-11-01 08:37:08 +01:00
Martin Jaeger c70f4cb2c3 Support for custom configuration added to platformio.ini 2019-11-01 08:18:57 +01:00
Martin Jäger a147bdf81b Merge pull request #67 from LibreSolar/load-protection-improvements 2019-11-01 08:15:08 +01:00
Martin Jaeger 20bc6d124b Fix to prevent toggling between load states disabled and low SOC 2019-10-31 19:50:55 +01:00
Martin Jaeger cb0c3c8135 USB output state machine improved (see #69) 2019-10-31 16:32:03 +01:00
Martin Jaeger b98461fee4 Load off for internal overtemp implemented 2019-10-31 12:07:21 +01:00
Martin Jaeger b1a7babaff Load overcurrent model now using internal temperature 2019-10-31 11:33:18 +01:00
Martin Jaeger b0e265f3e9 NTC on PCB not used as battery temperature anymore
- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
2019-10-31 11:22:03 +01:00
Martin Jaeger 5b4df98656 Load protection improvements
- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
  battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
2019-10-30 17:31:16 +01:00
Martin Jaeger 975c03affd Load OC/UV recovery settings fixed 2019-10-30 15:13:58 +01:00
azeemshatp 6bc2adb793 Bootloader support for STM32L07x MCUs (#65)
A custom linker script (.ld) is added to the root project folder. platformio.ini file updated to add the new env: pwm-2420-lus-v0.3-bl and build_flags. Start address for each Application in the flash need to be is modified in this .ld file. Readme file is updated accordingly. New functions added to perform flash write operations to store the bootloader status.
2019-10-28 13:30:19 +01:00
hogthrob e67123ac62 DCDC transfer doesn't work fix for STM32F0 based boards (#66) 2019-10-27 13:57:15 +01:00
Martin Jäger f14df2bc9d Global print functions based on debug level flags added (closes #58) 2019-10-25 11:36:01 +02:00
Hogthrob 88f2accbd9 Reduced code duplication in dcdc code 2019-10-24 17:06:11 +02:00
Martin Jaeger a7239fa9bb Enabled all warnings for unit-test builds 2019-10-24 16:10:35 +02:00
Martin Jaeger 68ae3227cc Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
2019-10-24 16:04:32 +02:00
Martin Jäger 2beb72f1f6 Merge pull request #62 from LibreSolar/playground
Rework of port concept and charge controller type setup
2019-10-24 15:58:19 +02:00
Martin Jaeger ba10a2882c Fixing load output and improved overvoltage config
Previous load output expected the battery port as a parameter and checked if
discharging of the battery was allowed. New implementation has own load port
and needs to check if current output (i.e. positive direction) is allowed.

Overvoltage setting is now configured via power port sink_voltage_max.
2019-10-23 13:16:04 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger 515b098e85 Passing of bat voltage and current limits to other ports updated 2019-10-23 07:29:05 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger a89ac7ff4b Fixing not working references to bat/solar ports in data_objects 2019-10-21 18:00:27 +02:00
Martin Jaeger 8558cef9cb PWM switch also implemented as class 2019-10-20 22:01:45 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
hogthrob c5fd08d836 Fix rounding issue (#60)
In some cases the old code would cause a +1/-1 step not actually changing the PWM due to rounding issues.
New code directly changes the integer value and thus avoids this issue.
2019-10-20 13:50:56 +02:00
Martin Jaeger d7ed3cdd13 STM32 bootloader activation from SW via BOOT0 pin 2019-10-18 17:01:33 +02:00
Martin Jaeger 29e186624c ThingSet device renamed to interface
Reason: According to ThingSet spec, a device is a complete physical hardware device like a charge controller.
Within one device, we can have different communication interfaces that use the ThingSet protocol.
2019-10-17 10:36:48 +02:00
Martin Jaeger 6c3885e5d0 Log unit-tests added 2019-10-16 21:32:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger cce6e2a9b3 Added main.h for common includes and extern variables 2019-10-16 12:03:49 +02:00
Martin Jaeger 0545131a99 Equalization charging phase added 2019-10-16 10:02:27 +02:00
hogthrob 472fb03cc6 Small fix for building unit test on Windows (#56)
Was necessary to add -D __STDC_FORMAT_MACROS for MinGW gcc 8.1.0
2019-10-16 06:29:12 +02:00
Martin Jaeger aeeff56492 Update mbed to v5.13.4 after testing 2019-10-15 16:48:14 +02:00