Commit Graph
47 Commits
Author SHA1 Message Date
Martin Jäger 4f4bdc70ae PWM switch: Clean up comments and add F suffixes 2020-12-13 11:04:56 +01:00
Martin Jäger 7cd89bc04a PWM switch: Fix start voltage check
Previous statement didn't consider the series multiplier in case of 24V
battery.
2020-11-05 20:38:55 +01:00
Martin Jäger c6709f8f00 Rename (Dcdc|PwmSwitch)::emergency_stop to stop
The stop functions can be used in a generic way, not only in an emergency
situation. The name was misleading.
2020-11-05 20:36:51 +01:00
Martin Jäger c2ef955a63 Replace custom print_* with Zephyr LOG_* 2020-07-23 17:34:41 +02:00
Martin Jäger dc4576c8b4 Remove all board.h files
Final updates to devicetree files (adding temperature sensor information) make
board.h files obsolete.
2020-07-23 17:34:41 +02:00
Martin Jäger a584904470 Switch to new DT_ macros 2020-07-23 17:34:39 +02:00
Martin Jäger d283436747 Move ADC peripheral setup to devicetree
Remove the ADC channel configuration from the board.h files and use new
DT macros to configure the ADC peripheral based on board.dts only.
2020-07-20 09:07:31 +02:00
Martin Jäger 3eb70e9a01 Add test/zephyr.h to mock Zephyr functions/defines 2020-06-04 16:28:19 +02:00
Martin Jäger d292ad425a Add PWM switch off inhibit 2020-05-06 12:53:26 +02:00
Martin Jäger 5e94d72117 Use LL for PWM switch driver to support STM32G4
This adds support for PWM solar input of MPPT 2420 HPX. Also adds new
PwmSwitch::test() function.
2020-05-06 12:53:26 +02:00
Martin Jäger 8dd576e40e Configure PWM switch driver via DTS
Driver now moved to separate .c file to allow ISR handling in Zephyr.
2020-05-06 12:53:26 +02:00
Martin Jäger ab504e3dfa DC/DC and PWM switch configuration via DTS
As these settings are clearly hardware-specific, configuration was
moved from Kconfig (hidden symbols) to DTS. New bindings added.
2020-05-06 12:53:26 +02:00
Martin Jäger 2a71d02aeb Move PCB and user config to board Kconfig
Files in src/pcbs/xyz.h are moved to boards/xyz/board.h. User settings from
src/config.h are also configured via Kconfig, so the file is removed.
2020-04-30 10:53:58 +02:00
Martin Jäger 1a9c290485 Charger.num_batteries moved to DcBus.series_multiplier
The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
2020-03-01 09:48:35 +01:00
Martin Jäger d40dafd8d9 Rename V_SOLAR/BAT pins to more generic V_HIGH/LOW 2020-02-20 11:06:44 +01:00
Martin Jäger 0c20545f88 Differentiate between src and sink droop res again
Necessary for improved load disconnect switch behavior.
2020-02-19 14:34:40 +01:00
Martin Jaeger 43f90eea7c Move voltage control parameters to DcBus class
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
2020-02-07 12:03:25 +01:00
Martin Jaeger a7d6dbc3b5 Let PWM switch class inherit from PowerPort
First step of unifying different ports connected to one bus. At a later
step, also the load and charger classes should inherit from PowerPort
class to make overall charge controller structure more clean.
2020-02-07 12:00:59 +01:00
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger eed8c9114c Coding style updated/fixed
Indentations of class definitions and preprocessor statements were not
uniform throughout the code. This commit cleans up indentations as well
as the order of include statements.

Style conventions see: https://github.com/LibreSolar/coding-style
2020-01-28 13:20:01 +01:00
Martin Jaeger 05292c12ba ADC & DMA renamed to DAQ (data acquisition) 2020-01-27 15:13:53 +01:00
Martin Jaeger a76b92c27b time(NULL) replaced with uptime() in helper files
Reason: Zephyr does not support time(NULL). This way it is portable.
2020-01-16 20:04:37 +01:00
Martin Jaeger cb988639ce Zephyr: Added PWM 2420 LUS board 2020-01-09 13:56:02 +01:00
Martin Jaeger 16ca793bb3 Port configuration based on Kconfig implemented 2020-01-06 19:16:44 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger 47954166be Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage
- Hysteresis for load overvoltage reconnect setpoint made configurable
- Added check for PWM switch MOSFET driver undervoltage
2019-11-11 11:38:34 +01:00
Martin Jaeger c26c17221a Overvoltage alert improved for PWM switching
Previously, the alert was sometimes erroneously triggered in PWM charger
absorption phase (constant voltage, PWM switching). Now the overvoltage
alert is inhibited during turn-on in each PWM cycle by an interrupt.
2019-11-08 13:06:17 +01:00
Martin Jaeger 4c5401d562 PWM switch max current limit control fixed 2019-11-06 10:49:40 +01:00
Martin Jaeger 5e3181f5e5 Distinguishing between OV and UV alerts, inhibit added
- During overvoltage alerts, only power sources (PWM switch and DC/DC are
  switched off), undervoltage only switches load off
- Alert inhibit added to prevent switching off during PWM switch startup
2019-11-05 18:43:33 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
Martin Jaeger 7412b11002 ADC filtering in separate function + unit-tests 2019-11-04 18:02:43 +01:00
Martin Jaeger a7239fa9bb Enabled all warnings for unit-test builds 2019-10-24 16:10:35 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger 8558cef9cb PWM switch also implemented as class 2019-10-20 22:01:45 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 3f4f52ea18 PWM switch: Bug fixed + some improvements
- Serious bug: Switch did not go below 90% duty cycle (left-over from testing code). Could result in overcharging of battery.
- Improvement: Preventing very short on/off times (duty cycles close to 0 or 1) as switching time is quite slow
- PWM frequency now configurable via PCB config (and increased from 20 to 25 Hz)
- Some unused parameters in PwmSwitch struct removed and variables renamed
- Overcurrent setting now via solar_bus
2019-08-16 11:37:25 +02:00
Martin Jaeger c968a6bb8a Structs renamed for new coding style (closes #42) 2019-08-08 10:16:16 +02:00
Martin Jaeger dec36143dd 12V/24V detection added and bat_charger restructured 2019-05-23 22:16:41 +02:00
Martin Jaeger b742fe6671 Energy calculation for PWM CC fixed
- Correct negative sign for incoming solar current
- Current multiplied with PWM duty cycle to get average current
- Min/max calculation moved to log.cpp
2019-05-15 11:06:49 +02:00
Martin Jaeger 7c75548193 DC bus type introduced and unit tests added 2019-05-07 18:56:04 +02:00
Martin Jaeger d9f7103e97 Starting test-driven development (TDD) with Unity
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory
2019-05-04 11:31:37 +02:00
Martin Jaeger e05fd95e17 Current compensation for load switch thresholds added 2019-04-18 09:23:58 +02:00
Martin Jaeger 666ca02baf Min/max recordings added to serial pub message 2019-04-17 08:18:44 +02:00
Martin Jaeger 627797ed36 PWM synchronized solar current/voltage measurement implemented 2019-04-01 20:09:27 +02:00