PWM switch: Bug fixed + some improvements
- Serious bug: Switch did not go below 90% duty cycle (left-over from testing code). Could result in overcharging of battery. - Improvement: Preventing very short on/off times (duty cycles close to 0 or 1) as switching time is quite slow - PWM frequency now configurable via PCB config (and increased from 20 to 25 Hz) - Some unused parameters in PwmSwitch struct removed and variables renamed - Overcurrent setting now via solar_bus
This commit is contained in:
+2
-2
@@ -16,12 +16,12 @@
|
||||
|
||||
#include "dc_bus.h"
|
||||
|
||||
void dc_bus_init_solar(DcBus *bus)
|
||||
void dc_bus_init_solar(DcBus *bus, float max_abs_current)
|
||||
{
|
||||
bus->dis_allowed = true; // PV panel may provide power to solar input of DC/DC
|
||||
bus->dis_voltage_start = 16.0;
|
||||
bus->dis_voltage_stop = 14.0;
|
||||
bus->dis_current_max = -18.0;
|
||||
bus->dis_current_max = -max_abs_current;
|
||||
|
||||
bus->chg_allowed = false;
|
||||
}
|
||||
|
||||
+4
-1
@@ -56,8 +56,11 @@ typedef struct {
|
||||
} DcBus;
|
||||
|
||||
/** Initialize dc bus for solar panel connection
|
||||
*
|
||||
* @param bus The DC bus struct to initialize
|
||||
* @param max_abs_current Maximum input current allowed by PCB (as a positive value)
|
||||
*/
|
||||
void dc_bus_init_solar(DcBus *bus);
|
||||
void dc_bus_init_solar(DcBus *bus, float max_abs_current);
|
||||
|
||||
/** Initialize dc bus for nanogrid connection
|
||||
*/
|
||||
|
||||
+5
-1
@@ -19,6 +19,8 @@
|
||||
#include "pcb.h"
|
||||
#include "log.h"
|
||||
|
||||
#ifndef CHARGER_TYPE_PWM
|
||||
|
||||
#include "half_bridge.h"
|
||||
|
||||
#include <time.h> // for time(NULL) function
|
||||
@@ -181,7 +183,7 @@ void dcdc_control(Dcdc *dcdc, DcBus *hs, DcBus *ls)
|
||||
}
|
||||
}
|
||||
|
||||
void Dcdcest(Dcdc *dcdc, DcBus *hs, DcBus *ls)
|
||||
void dcdc_test(Dcdc *dcdc, DcBus *hs, DcBus *ls)
|
||||
{
|
||||
if (half_bridge_enabled()) {
|
||||
if (half_bridge_get_duty_cycle() > 0.5) {
|
||||
@@ -225,3 +227,5 @@ void dcdc_self_destruction()
|
||||
//half_bridge_start(0);
|
||||
// now the fuse should be triggered and we disappear
|
||||
}
|
||||
|
||||
#endif /* CHARGER_TYPE_PWM */
|
||||
|
||||
+1
-1
@@ -107,7 +107,7 @@ void dcdc_control(Dcdc *dcdc, DcBus *high_side, DcBus *low_side);
|
||||
* @param high_side High-side power port (e.g. solar input for typical MPPT charge controller application)
|
||||
* @param low_side Low-side power port (e.g. battery output for typical MPPT charge controller application)
|
||||
*/
|
||||
void Dcdcest(Dcdc *dcdc, DcBus *high_side, DcBus *low_side);
|
||||
void dcdc_test(Dcdc *dcdc, DcBus *high_side, DcBus *low_side);
|
||||
|
||||
/** Prevent overcharging of battery in case of shorted HS MOSFET
|
||||
*
|
||||
|
||||
+8
-3
@@ -117,7 +117,7 @@ int main()
|
||||
#else // MPPT
|
||||
dcdc_init(&dcdc);
|
||||
half_bridge_init(PWM_FREQUENCY, PWM_DEADTIME, 12 / dcdc.hs_voltage_max, 0.97); // lower duty limit might have to be adjusted dynamically depending on LS voltage
|
||||
#endif
|
||||
#endif
|
||||
|
||||
// Configuration from EEPROM
|
||||
data_objects_read_eeprom();
|
||||
@@ -145,6 +145,10 @@ int main()
|
||||
uext_init();
|
||||
init_watchdog(10); // 10s should be enough for communication ports
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
dc_bus_init_solar(&hv_bus, PWM_CURRENT_MAX);
|
||||
bat_bus = &lv_bus;
|
||||
#else
|
||||
// Setup of DC/DC power stage
|
||||
switch(dcdc.mode) {
|
||||
case MODE_NANOGRID:
|
||||
@@ -152,14 +156,15 @@ int main()
|
||||
bat_bus = &lv_bus;
|
||||
break;
|
||||
case MODE_MPPT_BUCK: // typical MPPT charge controller operation
|
||||
dc_bus_init_solar(&hv_bus);
|
||||
dc_bus_init_solar(&hv_bus, DCDC_CURRENT_MAX);
|
||||
bat_bus = &lv_bus;
|
||||
break;
|
||||
case MODE_MPPT_BOOST: // for charging of e-bike battery via solar panel
|
||||
dc_bus_init_solar(&lv_bus);
|
||||
dc_bus_init_solar(&lv_bus, DCDC_CURRENT_MAX);
|
||||
bat_bus = &hv_bus;
|
||||
break;
|
||||
}
|
||||
#endif
|
||||
charger_detect_num_batteries(&charger, &bat_conf, bat_bus); // check if we have 24V instead of 12V system
|
||||
battery_init_dc_bus(bat_bus, &bat_conf, charger.num_batteries);
|
||||
|
||||
|
||||
@@ -25,9 +25,10 @@
|
||||
#define CHARGER_TYPE_PWM 1 // PWM charge controller instead of MPPT
|
||||
|
||||
#define PWM_TIM 3 // use TIM3 timer
|
||||
#define PWM_FREQUENCY 25 // Hz
|
||||
|
||||
#define DCDC_CURRENT_MAX 20 // PCB maximum DCDC output current
|
||||
#define LOAD_CURRENT_MAX 20 // PCB maximum load switch current
|
||||
#define PWM_CURRENT_MAX 20 // PCB maximum PWM switch (solar) current
|
||||
#define LOAD_CURRENT_MAX 20 // PCB maximum load switch current
|
||||
|
||||
#define LOW_SIDE_VOLTAGE_MAX 30 // Maximum voltage at battery port (V)
|
||||
#define HIGH_SIDE_VOLTAGE_MAX 55 // Maximum voltage at PV input port (V)
|
||||
|
||||
+43
-38
@@ -21,8 +21,6 @@
|
||||
#include "pcb.h"
|
||||
|
||||
#include <time.h> // for time(NULL) function
|
||||
#include <math.h> // for fabs function
|
||||
|
||||
|
||||
// timer used for PWM generation has to be globally selected for the used PCB
|
||||
#if (PWM_TIM == 3) && defined(CHARGER_TYPE_PWM)
|
||||
@@ -46,7 +44,7 @@ void pwm_switch_init_registers(int freq_Hz)
|
||||
GPIOB->AFR[0] |= 0x2 << GPIO_AFRL_AFRL1_Pos;
|
||||
|
||||
// Set timer clock to 10 kHz
|
||||
TIM3->PSC = SystemCoreClock / 10000;
|
||||
TIM3->PSC = SystemCoreClock / 10000 - 1;
|
||||
|
||||
// Capture/Compare Mode Register 1
|
||||
// OCxM = 110: Select PWM mode 1 on OCx
|
||||
@@ -68,7 +66,8 @@ void pwm_switch_init_registers(int freq_Hz)
|
||||
_pwm_resolution = 10000 / freq_Hz;
|
||||
|
||||
// Auto Reload Register
|
||||
TIM3->ARR = _pwm_resolution;
|
||||
// Period goes from 0 to ARR (including ARR value), so substract 1 clock cycle
|
||||
TIM3->ARR = _pwm_resolution - 1;
|
||||
}
|
||||
|
||||
void pwm_switch_set_duty_cycle(float duty)
|
||||
@@ -78,7 +77,7 @@ void pwm_switch_set_duty_cycle(float duty)
|
||||
|
||||
void pwm_switch_duty_cycle_step(int delta)
|
||||
{
|
||||
if ((int)TIM3->CCR4 + delta <= (_pwm_resolution + 1) && (int)TIM3->CCR4 + delta >= 0) {
|
||||
if ((int)TIM3->CCR4 + delta <= _pwm_resolution && (int)TIM3->CCR4 + delta >= 0) {
|
||||
TIM3->CCR4 += delta;
|
||||
}
|
||||
}
|
||||
@@ -88,9 +87,9 @@ bool pwm_switch_enabled()
|
||||
return _enabled;
|
||||
}
|
||||
|
||||
float pwm_switch_get_duty_cycle() {
|
||||
// TODO: check why we might get > 100
|
||||
return (float)(TIM3->CCR4) / (_pwm_resolution);
|
||||
float pwm_switch_get_duty_cycle()
|
||||
{
|
||||
return (float)(TIM3->CCR4) / _pwm_resolution;
|
||||
}
|
||||
|
||||
void pwm_switch_start(float pwm_duty)
|
||||
@@ -110,57 +109,71 @@ void pwm_switch_start(float pwm_duty)
|
||||
void pwm_switch_stop()
|
||||
{
|
||||
TIM3->CCER &= ~(TIM_CCER_CC4E);
|
||||
|
||||
TIM3->CCR4 = 0;
|
||||
_enabled = false;
|
||||
}
|
||||
|
||||
void pwm_switch_init(PwmSwitch *pwm_switch)
|
||||
{
|
||||
pwm_switch->solar_current_max = DCDC_CURRENT_MAX;
|
||||
pwm_switch->solar_current_min = 0.05;
|
||||
|
||||
//pwm_switch->pwm_delta = 1;
|
||||
pwm_switch->off_timestamp = -10000; // start immediately
|
||||
|
||||
// calibration parameters
|
||||
//pwm_switch->offset_voltage_start = 3.0; // V charging switched on if Vsolar > Vbat + offset
|
||||
//pwm_switch->offset_voltage_stop = 1.0; // V charging switched off if Vsolar < Vbat + offset
|
||||
pwm_switch->offset_voltage_start = 2.0; // V charging switched on if Vsolar > Vbat + offset
|
||||
pwm_switch->restart_interval = 60; // s When should we retry to start charging after low solar power cut-off?
|
||||
|
||||
pwm_switch_init_registers(20);
|
||||
pwm_switch_init_registers(PWM_FREQUENCY);
|
||||
|
||||
pwm_switch->enabled = true; // enable charging in general
|
||||
_enabled = false; // still disable actual switch
|
||||
}
|
||||
|
||||
void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_port, DcBus *bat_port)
|
||||
void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_bus, DcBus *bat_bus)
|
||||
{
|
||||
if (_enabled) {
|
||||
if (bat_port->chg_allowed == false || solar_port->dis_allowed == false
|
||||
|| (solar_port->voltage < solar_port->dis_voltage_stop && solar_port->current > 0)
|
||||
if (bat_bus->chg_allowed == false || solar_bus->dis_allowed == false
|
||||
|| solar_bus->current > 0 // discharging battery into solar panel --> stop
|
||||
|| pwm_switch->enabled == false)
|
||||
{
|
||||
pwm_switch_stop();
|
||||
pwm_switch->off_timestamp = time(NULL);
|
||||
printf("PWM charger stop.\n");
|
||||
}
|
||||
else if (bat_port->voltage > (bat_port->chg_voltage_target - bat_port->chg_droop_res * bat_port->current) // output voltage above target
|
||||
|| bat_port->current > bat_port->chg_current_max // output current limit exceeded
|
||||
|| solar_port->current < solar_port->dis_current_max) // input current (negative signs) above limit
|
||||
else if (bat_bus->voltage > (bat_bus->chg_voltage_target - bat_bus->chg_droop_res * bat_bus->current) // output voltage above target
|
||||
|| bat_bus->current > bat_bus->chg_current_max // output current limit exceeded
|
||||
|| solar_bus->current < solar_bus->dis_current_max) // input current (negative signs) above limit
|
||||
{
|
||||
if (pwm_switch_get_duty_cycle() > 0.9)
|
||||
// The gate driver switch-off time is quite high (fall time around 1ms), so very short
|
||||
// on or off periods (duty cycle close to 0 and 1) should be avoided
|
||||
if (pwm_switch_get_duty_cycle() > 0.95) {
|
||||
// prevent very short off periods
|
||||
pwm_switch_set_duty_cycle(0.95);
|
||||
}
|
||||
else if (pwm_switch_get_duty_cycle() < 0.05) {
|
||||
// prevent very short on periods and switch completely off instead
|
||||
pwm_switch_stop();
|
||||
pwm_switch->off_timestamp = time(NULL);
|
||||
printf("PWM charger stop, no further derating possible.\n");
|
||||
}
|
||||
else {
|
||||
pwm_switch_duty_cycle_step(-1);
|
||||
}
|
||||
}
|
||||
else {
|
||||
pwm_switch_duty_cycle_step(1);
|
||||
if (pwm_switch_get_duty_cycle() > 0.95) {
|
||||
// prevent very short off periods and switch completely on instead
|
||||
pwm_switch_set_duty_cycle(1);
|
||||
}
|
||||
else {
|
||||
pwm_switch_duty_cycle_step(1);
|
||||
}
|
||||
}
|
||||
}
|
||||
else {
|
||||
if (bat_port->chg_allowed == true
|
||||
&& bat_port->voltage < bat_port->chg_voltage_target
|
||||
&& bat_port->voltage > bat_port->chg_voltage_min
|
||||
&& solar_port->dis_allowed == true
|
||||
&& solar_port->voltage > solar_port->dis_voltage_start
|
||||
if (bat_bus->chg_allowed == true
|
||||
&& bat_bus->voltage < bat_bus->chg_voltage_target
|
||||
&& bat_bus->voltage > bat_bus->chg_voltage_min
|
||||
&& solar_bus->dis_allowed == true
|
||||
&& solar_bus->voltage > bat_bus->voltage + pwm_switch->offset_voltage_start
|
||||
&& time(NULL) > (pwm_switch->off_timestamp + pwm_switch->restart_interval)
|
||||
&& pwm_switch->enabled == true)
|
||||
{
|
||||
@@ -170,14 +183,6 @@ void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_port, DcBus *bat_por
|
||||
}
|
||||
}
|
||||
|
||||
#else
|
||||
|
||||
// dummy functions for non-PWM charge controllers
|
||||
void pwm_switch_init(PwmSwitch *pwm_switch) {}
|
||||
void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_port, DcBus *bat_port) {}
|
||||
void pwm_switch_duty_cycle_step(int delta) {}
|
||||
bool pwm_switch_enabled() {return false;}
|
||||
|
||||
#endif
|
||||
#endif /* CHARGER_TYPE_PWM */
|
||||
|
||||
#endif /* UNIT_TEST */
|
||||
|
||||
+17
-22
@@ -27,36 +27,31 @@
|
||||
|
||||
/** PWM charger type
|
||||
*
|
||||
* Contains all data belonging to the PWM switching sub-component of the PCB, incl.
|
||||
* actual measurements and calibration parameters.
|
||||
* Contains all data belonging to the PWM switching sub-component.
|
||||
*/
|
||||
typedef struct {
|
||||
bool enabled; ///< Can be used to disable the PWM power stage
|
||||
|
||||
// actual measurements
|
||||
float solar_current;
|
||||
float temp_mosfets;
|
||||
float solar_power;
|
||||
|
||||
float solar_current_max; // MOSFET maximum (continuous)
|
||||
float solar_current_min; // --> if lower, charger is switched off
|
||||
|
||||
int pwm_delta; // direction of PWM change
|
||||
int off_timestamp; // time when charger was switched off last time
|
||||
|
||||
// calibration parameters
|
||||
float offset_voltage_start; // V charging switched on if Vsolar > Vbat + offset
|
||||
float offset_voltage_stop; // V charging switched off if Vsolar < Vbat + offset
|
||||
int restart_interval; // s When should we retry to start charging after low solar power cut-off?
|
||||
float offset_voltage_start; ///< Offset voltage of solar panel vs. battery to start charging (V)
|
||||
int restart_interval; ///< Interval to wait before retrying charging after low solar power cut-off (s)
|
||||
int off_timestamp; ///< Time when charger was switched off last time
|
||||
} PwmSwitch;
|
||||
|
||||
|
||||
/** Initialization of PWM switch struct
|
||||
*/
|
||||
void pwm_switch_init(PwmSwitch *pwm_switch);
|
||||
|
||||
void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_port, DcBus *bat_port);
|
||||
|
||||
void pwm_switch_duty_cycle_step(int delta);
|
||||
/** Main control function for the PWM switching algorithm
|
||||
*
|
||||
* @param pwm_switch PWM switch struct
|
||||
* @param solar_bus Solar connector DC bus struct
|
||||
* @param bat_bus Battery connector DC bus struct
|
||||
*/
|
||||
void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_bus, DcBus *bat_bus);
|
||||
|
||||
/** Read the on/off status of the PWM switch
|
||||
*
|
||||
* @returns true if enabled
|
||||
*/
|
||||
bool pwm_switch_enabled();
|
||||
|
||||
/** Read the currently set duty cycle
|
||||
|
||||
@@ -105,7 +105,11 @@ void uext_process_1s()
|
||||
oled.drawRect(66, 4, 2, 5, 1); // bar 5
|
||||
|
||||
// solar panel data
|
||||
if (half_bridge_enabled() || pwm_switch_enabled()) {
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
if (pwm_switch_enabled()) {
|
||||
#else
|
||||
if (half_bridge_enabled()) {
|
||||
#endif
|
||||
tmp = - hv_bus.voltage * hv_bus.current;
|
||||
oled.setTextCursor(0, 18);
|
||||
oled.printf("%4.0fW", (abs(tmp) < 1) ? 0 : tmp); // remove negative zeros
|
||||
|
||||
Reference in New Issue
Block a user