- Increase PWM step size to see differences between each controller run
- Take ADC2 measurements (current sensors) synchronous to voltages
(previous approach with high-rate current measurement once per PWM
cycle only makes sense for cycle-by-cylce control, not for slow MPPT)
The controllers with fast ADC sampling speed were sometimes switched off
immediately after turn-on. Switching off at negative power flow is only an
additional safety measure. Normally the controller should switch off
reliably because of power_good_timestamp already.
The previous approach to define the pinmux in the timer nodes didn't work
because the timers don't have a pinctrl-0 property. This commit adds a new
half-bridge binding similar to upstream Zephyr pwm binding, which is a child
node of the used timer.
It makes sense to define PWM frequency and dead-time also in this node, so
the dcdc devicetree binding is redundant and therefore removed.
This allows us to enable e.g debug output for the CAN module with
CONFIG_CAN_LOG_LEVEL=4 without enabling the global
CONFIG_LOG_DEFAULT_LEVEL=4 and being swamped with debug output from
all of Zephyr's subsytems.
This makes more sense because the DC/DC converter actually connects two
DcBuses and does not need separate PowerPorts. Also makes the code look
more clean as variable access like dcdc.hvs->bus->voltage is avoided.
The DcBus pointers in the Dcdc are now called hvb and lvb for high-
voltage side bus and low-voltage side bus.
These variables define the voltage at zero current, which is the y axis
intercept of the droop curve (voltage vs. current).
As they do not always specifiy minimum or maximum boundary depending on
the sign of the droop resistance, intercept is a more suitable name.
New control states allow to specify the reason for derating more detailed,
also considering the input side.
The operation mode is now also used as a return value for
check_start_conditions function to get rid of magic numbers.
The check for high-side MOSFET shorts and startup inhibit are moved to
separate functions to keep the general control function more clean.
Also declared check_start_conditions weak to allow custom overriding.
A Kconfig CUSTOM_DCDC_CONTROLLER is introduced to enable implementation of
more sophisticated control functions than the standard perturb and observe.
A function dcdc_low_level_controller() must be implemented and is called
from the DMA interrupt after each new current sensor reading.
The default Dcdc::control() function is defined __weak.
The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
Indentations of class definitions and preprocessor statements were not
uniform throughout the code. This commit cleans up indentations as well
as the order of include statements.
Style conventions see: https://github.com/LibreSolar/coding-style
We should use src_voltage_stop as limit,
since the input voltage start limit is basically an OC voltage
where as the stop voltage is a voltage to be measured under load.
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
In addition to the normal error flags we now have
ERR_ANY_ERROR which may be used to clear all errors
at once or to use in has_error to see if there is any error flag set.
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.