Improve MPPT behavior for STM32G4 series
- Increase PWM step size to see differences between each controller run - Take ADC2 measurements (current sensors) synchronous to voltages (previous approach with high-rate current measurement once per PWM cycle only makes sense for cycle-by-cylce control, not for slow MPPT)
This commit is contained in:
+3
-7
@@ -229,12 +229,6 @@ static void adc_init(ADC_TypeDef *adc)
|
||||
// Enable DMA transfer on ADC and circular mode
|
||||
LL_ADC_REG_SetDMATransfer(adc, LL_ADC_REG_DMA_TRANSFER_UNLIMITED);
|
||||
|
||||
#if defined(CONFIG_SOC_SERIES_STM32G4X)
|
||||
if (adc == ADC2) {
|
||||
LL_ADC_REG_SetTriggerEdge(adc, LL_ADC_REG_TRIG_EXT_RISING);
|
||||
LL_ADC_REG_SetTriggerSource(adc, LL_ADC_REG_TRIG_EXT_TIM1_TRGO2);
|
||||
}
|
||||
#endif
|
||||
LL_ADC_Enable(adc);
|
||||
}
|
||||
|
||||
@@ -259,7 +253,9 @@ static inline void adc_trigger_conversion(struct k_timer *timer_id)
|
||||
{
|
||||
LL_ADC_REG_StartConversion(ADC1);
|
||||
|
||||
// ADC2 (if existing) is triggered by the PWM timer
|
||||
#if defined(CONFIG_SOC_SERIES_STM32G4X)
|
||||
LL_ADC_REG_StartConversion(ADC2);
|
||||
#endif
|
||||
}
|
||||
|
||||
static void DMA1_Channel1_IRQHandler(void *args)
|
||||
|
||||
@@ -142,8 +142,13 @@ int Dcdc::perturb_observe_controller()
|
||||
|
||||
power_prev = out_power;
|
||||
|
||||
#ifdef CONFIG_SOC_SERIES_STM32G4X
|
||||
// reduced step size for fast microcontroller
|
||||
half_bridge_set_ccr(half_bridge_get_ccr() + pwr_inc_goal * pwr_inc_pwm_direction * 3);
|
||||
#else
|
||||
// change duty cycle by single minimum step
|
||||
half_bridge_set_ccr(half_bridge_get_ccr() + pwr_inc_goal * pwr_inc_pwm_direction);
|
||||
#endif
|
||||
|
||||
return (pwr_inc_goal == 0);
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user