2019-03-05 15:32:41 +01:00
2016-08-02 14:02:09 +02:00
2019-11-11 21:02:26 +01:00
2017-04-14 18:04:13 +02:00

Libre Solar Charge Controller Firmware

build badge

Firmware based on ARM mbed framework for the Libre Solar MPPT/PWM solar charge controllers

Supported devices

The software is configurable to support different charge controller PCBs with either STM32F072 (including CAN support) or low-power STM32L072/3 MCUs.

Building and flashing the firmware

This firmware is developed using the ARM mbed OS embedded framework which has easy-to-understand C++ syntax (similar to Arduino) and thus enhances community based software development.

If used together with Visual Studio Code and PlatformIO, starting firmware development is only a matter of a few clicks:

  1. Install Visual Studio Code and PlatformIO to build the firmware.

  2. Copy src/config.h_template to src/config.h, and adjust basic settings. config.h is ignored by git, so your changes are kept after software updates using git pull.

  3. Select the correct board in platformio.ini by removing the comment before the board name under [platformio] or create a file custom.ini with your personal settings.

  4. Connect the board via a programmer. See the Libre Solar website for further project-agnostic instructions.

  5. Press the upload button at the bottom left corner in VS Code.

Troubleshooting

Errors with STM32L072 MCU using OpenOCD

The standard OpenOCD settings sometimes fail to flash firmware to this MCU, which is used in the MPPT 1210 HUS and the PWM charge controller.

Try one of these workarounds:

  1. Change OpenOCD settings to set WORKAREASIZE 0x1000 in the file ~/.platformio/packages/tool-openocd/scripts/board/st_nucleo_l073rz.cfg.

  2. Use ST-Link tools. For Windows there is a GUI tool. Under Linux, uncomment the upload_command line in platformio.ini.

  3. Use other debuggers and tools, e.g. Segger J-Link.

Connection failures

If flashing fails like this in PlatformIO:

Error: init mode failed (unable to connect to the target)
in procedure 'program'
** OpenOCD init failed **
shutdown command invoked

or with ST-Link:

$ st-flash write .pio/build/mppt-1210-hus-v0.4/firmware.bin 0x08000000
st-flash 1.5.1
2019-06-21T18:13:03 INFO common.c: Loading device parameters....
2019-06-21T18:13:03 WARN common.c: unknown chip id! 0x5fa0004

check the connection between the programmer (for example the ST-Link of the Nucleo board) and the charge controller.

Bootloader Support (STM32L07x only)

The custom linker script file STM32L073XZ.ld.link_script.ld needs to be updated before generating the application firmware binary. For each application, the flash start address and the maximum code size need to be updated in this file. Currently, the locations 0x08001000 and 0x08018000 are used for applications 1 & 2 respectively.

API documentation

The documentation auto-generated by Doxygen can be found here.

Unit tests

In order to run the unit tests, you need a PlatformIO Plus account. Run tests with the following command:

platformio test -e unit-test-native

Additional firmware documentation (docs folder)

S
Description
Firmware for Libre Solar MPPT/PWM charge controllers
https://libre.solar/charge-controller-firmware/
Readme
5.7 MiB
Languages
C++ 77.6%
C 18.1%
CMake 1.6%
Python 1.4%
Shell 0.7%
Other 0.6%