43 Commits
Author SHA1 Message Date
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger 3f89943edf ThingSet interfaces merged with Ext interfaces 2019-12-20 10:43:51 +01:00
Martin Jaeger 62f2f1978c UEXT and ThingSet code moved to ext folder 2019-12-20 10:38:31 +01:00
Martin Jaeger 74b765e801 Trailing white spaces removed 2019-11-21 07:44:15 +01:00
Martin Jaeger 47954166be Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage
- Hysteresis for load overvoltage reconnect setpoint made configurable
- Added check for PWM switch MOSFET driver undervoltage
2019-11-11 11:38:34 +01:00
Martin Jaeger f254c77ab6 Refactoring of load control and state machine
- State machine and control merged to one function
- Load states marked as deprecated, global error flags used instead
- Reduced duplicated code and made load control function easier to read
2019-11-11 09:35:26 +01:00
hogthrob d1ff837c5e Overvoltage limit overflow fix (#80)
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.

Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
2019-11-10 17:55:43 +01:00
hogthrob ba7d379225 Refactored adc_dma.cpp for readability (#76)
- replaced the lengthy adc value formulas with respective functions
  to ease reading
- removed unecessary casts for alert callbacks
- added static to the internal global variables in order to hide them from the
  other compilation units
2019-11-09 23:13:00 +01:00
Martin Jaeger 328215dc8e Load overvoltage detection corrected and error flag comments added 2019-11-07 16:00:51 +01:00
Martin Jaeger 5e3181f5e5 Distinguishing between OV and UV alerts, inhibit added
- During overvoltage alerts, only power sources (PWM switch and DC/DC are
  switched off), undervoltage only switches load off
- Alert inhibit added to prevent switching off during PWM switch startup
2019-11-05 18:43:33 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
Martin Jaeger 7412b11002 ADC filtering in separate function + unit-tests 2019-11-04 18:02:43 +01:00
hogthrob bec02cb25b Switched to use power of 2 error numbers (#72)
In addition to the normal error flags we now have
ERR_ANY_ERROR which may be used to clear all errors
at once or to use in has_error to see if there is any error flag set.
2019-11-04 09:19:06 +01:00
hogthrob fd474e5350 Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code
completion), no performance loss due to inlining.
2019-11-02 08:22:00 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00
Martin Jaeger cb0c3c8135 USB output state machine improved (see #69) 2019-10-31 16:32:03 +01:00
Martin Jaeger b98461fee4 Load off for internal overtemp implemented 2019-10-31 12:07:21 +01:00
Martin Jaeger b0e265f3e9 NTC on PCB not used as battery temperature anymore
- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
2019-10-31 11:22:03 +01:00
Martin Jaeger 5b4df98656 Load protection improvements
- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
  battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
2019-10-30 17:31:16 +01:00
Martin Jaeger a7239fa9bb Enabled all warnings for unit-test builds 2019-10-24 16:10:35 +02:00
Martin Jaeger 68ae3227cc Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
2019-10-24 16:04:32 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger 515b098e85 Passing of bat voltage and current limits to other ports updated 2019-10-23 07:29:05 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger a89ac7ff4b Fixing not working references to bat/solar ports in data_objects 2019-10-21 18:00:27 +02:00
Martin Jaeger 8558cef9cb PWM switch also implemented as class 2019-10-20 22:01:45 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger 6c3885e5d0 Log unit-tests added 2019-10-16 21:32:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 0545131a99 Equalization charging phase added 2019-10-16 10:02:27 +02:00
Martin Jaeger 25e469516c DC/DC control functions cleaned up 2019-10-15 14:00:20 +02:00
Martin Jaeger ae51d7a0d7 Unit tests for DC/DC control added 2019-10-15 13:59:48 +02:00
Martin Jaeger e7317ae1d8 DC bus and terminal naming improved
- DcBus representing actual screw terminals renamed
- Internal DC bus at DC/DC low voltage side added for correct DC/DC control
- DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed.
- Unit tests updated

DC/DC control needs further improvements to make use of the changes
2019-10-15 13:57:23 +02:00
Martin Jaeger cb206b6864 DC/DC startup check reworked and unit-tests added 2019-10-15 13:54:05 +02:00
hogthrob 6d56003c8c Unified half bridge timer handling (#53)
* As much as possible code is shared between both timer abstractions.
* Unit tests added to main implementation file (stub removed)
2019-10-15 10:34:53 +02:00
Martin Jaeger c968a6bb8a Structs renamed for new coding style (closes #42) 2019-08-08 10:16:16 +02:00
Martin Jaeger 690e204a16 Solar, bat and load power added to data objects 2019-06-18 17:04:33 +02:00
Martin Jaeger dec36143dd 12V/24V detection added and bat_charger restructured 2019-05-23 22:16:41 +02:00
Martin Jaeger 7c75548193 DC bus type introduced and unit tests added 2019-05-07 18:56:04 +02:00
Martin Jaeger d9f7103e97 Starting test-driven development (TDD) with Unity
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory
2019-05-04 11:31:37 +02:00
Martin Jaeger 676948c5ad Removed unused unittest scripts 2019-03-10 16:26:59 +01:00
Martin Jäger 112f36b08b Update master branch with new features from development branch (#20)
* Major changes in DC/DC control and board support + ThingSet library added

* Small platformio.ini fixes
- added libignore for mbed-USBDevice to all STM32F072 builds
- add map file generation. Use text editor or AMAP (http://www.sikorskiy.net/prj/amap/)
to view and learn where the precious flash and ram goes to.
- fixed board define for LS 0.10 board

* Travis fix and more
- Now runs only a selected subset of all configurations (all STM32F072/L073)
- Added a src_filter to the cloudsolar_03 since L073 does not have CAN.
  Maybe there is a better way to do this. Also added libignore for USB
  to this environment.
- Added memory.map to .gitignore

* STML0 support improved + small changes

- STM32L0 now widely supported: PWM signal generation, ADC via DMA and display via I2C are working

- Old files for USB support (only F0) included into repository, as files in original mbed repository don't compile.

- CAN bus support only for F0 (added header defines to allow compilation)

* Cell & Pack Config refactoring: First work on #13.
Reorganized battery init a bit to get a better idea of how to split things.
All known chemistries are now supported with safe values (please check the values).

Added data for NMC (aka "normal" LiIo cells such as most 18650)
A configuration now declares itself to be valid or not after battery_init.

BAT_TYPE_NONE (formerly BAT_TYPE_DEFAULT, which equals 0) will not pass check
and thus is an invalid configuration, as a result an unconfigured
battery_t struct will not be considered valid by accident.

We should not continue to start normal operation if a battery configuration is not valid.
However, this is not yet implemented.

Also slightly changed interface to battery_init, now we pass the number of cells.

Moved the static pub_enabled into main.cpp to get ride of a ton of "unused static variable"
warnings.

* ThingSet moved to separate library

* Removed serious bug in PWM signal generation resulting in PWM with 0% duty cycle

* LED control via PWM for STM32L0 board added

* Gets rid of USB deprecated warnings in application code
This simply disables any warning regarding the use
of deprecated internals in mbed for now.
Since the "new" USBDevice code does not run on F0 or L0, we use old
one which works but generates warnings a lot.
If they ever remove the deprecated interface, we'll know sure enough
since then code will no longer compile.

* More battery init refactoring

In addition to the mandatory arguments cell type, number in series and capacity,
the code now accepts a partially configure battery_t structure (you provide
various voltage levels and charge currents) for Lithium based cells, checks the configuration values for sanity
and tries to adjust if outside valid operational limits. The defaults try
to balance between charging stress and capacity loss.
Charge is by default to about 90% maximum full charge, and discharge stops around
20%-30%.

For lead acid cells all voltage levels and currents are set / calculated based
on the mandatory parameters, no configuration of voltage levels possible.

We may change that, but I don't have enough no knowledge about valid ranges
etc.

I added a high voltage lithium chemistry for cells which have typically
4.35 voltage limit (vs. 4.2 normally).

* Added user configuration for battery and system operation mode
Copy the most relevant template to config.cpp and then compile.
config.cpp is intentionally not part of the git managed source code
since it represents the user specific configuration part
which varies across different firmware builds.

* Turn off MBED Deprecated Warning for Old USB Stack attempt 2
This time cross platform compatible...
And also fix the travis build issue

* Boost mode added and first updates for timer-based DC/DC control

- system_mode now distinguishes between MPPT_BOOST and MPPT_BUCK
- new function system_control() which does all important and fast control
stuff necessary for the DC/DC (will be included into interrupt in the
future)
- small correction in _dcdc_output_control() algorithm after test with e-bike
battery solar charging

* Naming of structs and enums adjusted

* Documentation amended and separate docs folder created.

* UNIT_TEST defines removed

* Timer for DC/DC control implemented, ADC timer updated

* Files restructured / renamed

- config.h is now pcb.h and contains only hardware-specific settings
- anything which communicates to the outside world (display, serial interface, etc)
  is now renamed to more generic "interface" instead of "output" and "communication".
  Use interface_<DEVICE>.cpp for implementations of specific interfaces.

* Updates in user configuration and interfaces

- Battery configuration can now be adjusted in battery_init_user in config.cpp
- New function battery_update_settings implemented to check new battery configuration for plausibility (also needed for later user-configuration via serial interface)
- Templates for GSM and LoRa interfaces created
- Restructuring of main to allow different interface configurations

* Travis CI adjusted to new config.h

* Load output templates added

* ThingSet library updated, interface processing updated, publication functions added

* Load output implementation updated and moved to load.cpp/h

* Energy calculation updated and eTotal changed to uint32_t

* Update firmware.md

* Issue monitor_speed typing mistake

We found a typing issue: "monitor_speed" is mistyped as "monitor_port".

* Major updates of recent months
2019-02-16 09:53:36 +01:00