Commit Graph
16 Commits
Author SHA1 Message Date
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger 05292c12ba ADC & DMA renamed to DAQ (data acquisition) 2020-01-27 15:13:53 +01:00
Martin Jaeger 41b4607cc7 Fix additional bug in load unit-test 2020-01-20 15:22:21 +01:00
Martin Jaeger 69747a588d Fix initialization bug in load unit-test 2020-01-20 10:41:48 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger 47954166be Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage
- Hysteresis for load overvoltage reconnect setpoint made configurable
- Added check for PWM switch MOSFET driver undervoltage
2019-11-11 11:38:34 +01:00
Martin Jaeger f254c77ab6 Refactoring of load control and state machine
- State machine and control merged to one function
- Load states marked as deprecated, global error flags used instead
- Reduced duplicated code and made load control function easier to read
2019-11-11 09:35:26 +01:00
Martin Jaeger 328215dc8e Load overvoltage detection corrected and error flag comments added 2019-11-07 16:00:51 +01:00
hogthrob bec02cb25b Switched to use power of 2 error numbers (#72)
In addition to the normal error flags we now have
ERR_ANY_ERROR which may be used to clear all errors
at once or to use in has_error to see if there is any error flag set.
2019-11-04 09:19:06 +01:00
hogthrob fd474e5350 Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code
completion), no performance loss due to inlining.
2019-11-02 08:22:00 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00
Martin Jaeger cb0c3c8135 USB output state machine improved (see #69) 2019-10-31 16:32:03 +01:00
Martin Jaeger b98461fee4 Load off for internal overtemp implemented 2019-10-31 12:07:21 +01:00
Martin Jaeger b0e265f3e9 NTC on PCB not used as battery temperature anymore
- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
2019-10-31 11:22:03 +01:00
Martin Jaeger 5b4df98656 Load protection improvements
- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
  battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
2019-10-30 17:31:16 +01:00
Martin Jaeger 68ae3227cc Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
2019-10-24 16:04:32 +02:00