Commit Graph
35 Commits
Author SHA1 Message Date
Martin Jäger daf43fb967 USB charging output control via LoadOutput class
- Introduce new CONFIG_HAS_USB_PWR_OUTPUT
- Improve charger.discharge_control function
- Add battery empty flag
2020-03-02 11:55:38 +01:00
Martin Jäger 1a9c290485 Charger.num_batteries moved to DcBus.series_multiplier
The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
2020-03-01 09:48:35 +01:00
Martin Jäger 0c20545f88 Differentiate between src and sink droop res again
Necessary for improved load disconnect switch behavior.
2020-02-19 14:34:40 +01:00
Martin Jaeger 6af8e6d93d Improve load voltage limits setup and update 2020-02-19 14:34:40 +01:00
Martin Jaeger 68e0336279 Add debounce counter for UV error detection
This prevents switching off the load output due to short undervoltage
events during startup of pumps etc. when the battery is at low SOC.
2020-02-19 14:34:40 +01:00
JordanSilverman 30968e471c Check incoming battery conf 2020-02-17 19:47:51 +01:00
Martin Jaeger 14249492a3 Improve full charge detection and topping control
The battery is only full if the topping voltage is still reached AND the
current is below cut-off threshold at the same time. This was not always
detected correctly with previous 2s target voltage monitoring interval.

In addition to that, a new timer was introduced to count seconds at target
voltage and improve full charge detection due to timeout.
2020-02-10 12:47:32 +00:00
Martin Jaeger 43f90eea7c Move voltage control parameters to DcBus class
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
2020-02-07 12:03:25 +01:00
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger eed8c9114c Coding style updated/fixed
Indentations of class definitions and preprocessor statements were not
uniform throughout the code. This commit cleans up indentations as well
as the order of include statements.

Style conventions see: https://github.com/LibreSolar/coding-style
2020-01-28 13:20:01 +01:00
Martin Jaeger a76b92c27b time(NULL) replaced with uptime() in helper files
Reason: Zephyr does not support time(NULL). This way it is portable.
2020-01-16 20:04:37 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
hogthrob d1ff837c5e Overvoltage limit overflow fix (#80)
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.

Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
2019-11-10 17:55:43 +01:00
Martin Jaeger c26c17221a Overvoltage alert improved for PWM switching
Previously, the alert was sometimes erroneously triggered in PWM charger
absorption phase (constant voltage, PWM switching). Now the overvoltage
alert is inhibited during turn-on in each PWM cycle by an interrupt.
2019-11-08 13:06:17 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
hogthrob fd474e5350 Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code
completion), no performance loss due to inlining.
2019-11-02 08:22:00 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00
Martin Jaeger 68ae3227cc Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
2019-10-24 16:04:32 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger 515b098e85 Passing of bat voltage and current limits to other ports updated 2019-10-23 07:29:05 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 0545131a99 Equalization charging phase added 2019-10-16 10:02:27 +02:00
Martin Jaeger 6d91e075b3 Update of DC/DC lv side targets based on bat + load 2019-10-15 16:46:24 +02:00
Martin Jaeger 0a2a38691b 12V/24V battery detection message updated (closes #43) 2019-08-08 11:36:13 +02:00
Martin Jaeger c968a6bb8a Structs renamed for new coding style (closes #42) 2019-08-08 10:16:16 +02:00
Martin Jaeger 4bc3f8bd1e Load voltage thresholds adjusted and inhibit added
During tests, the deep discharge counter increased by several 100 counts per day under certain circumstances, most probably because of quite small battery making the voltage toggle between disconnect and reconnect voltage. This commit suggests several improvements.

- Load reconnect voltage increased
- Don't reconnect before waiting at least 1h (lvd_timestamp in load.cpp)
- SOC filter calculation slightly changed to make sure 100% is reached fast enough.
2019-07-12 18:55:13 +02:00
Martin Jaeger cf5366c2ba Fix usable_capacity estimation to prevent wrong values before first full charge 2019-07-11 13:11:34 +02:00
Hogthrob f26fdce41f Fixed NMC battery configuration calculation
Now num_cell multiplier is used in all required places.
2019-06-20 07:26:39 +02:00
Martin Jaeger 977002b0e7 Sign for discharged Ah counter corrected 2019-05-27 11:21:35 +02:00
Martin Jaeger dec36143dd 12V/24V detection added and bat_charger restructured 2019-05-23 22:16:41 +02:00
Martin Jaeger 4e0b7f2a12 Restructuring of data types (structs) and files
- dcdc_port_t renamed to power_port_t for future use in PWM charge controllers
- structs.h split into battery.h, log.h and charger.h
- bat_charger.cpp/h split into battery.cpp/h and charger.cpp/h
2019-03-10 17:19:44 +01:00
Martin Jäger 112f36b08b Update master branch with new features from development branch (#20)
* Major changes in DC/DC control and board support + ThingSet library added

* Small platformio.ini fixes
- added libignore for mbed-USBDevice to all STM32F072 builds
- add map file generation. Use text editor or AMAP (http://www.sikorskiy.net/prj/amap/)
to view and learn where the precious flash and ram goes to.
- fixed board define for LS 0.10 board

* Travis fix and more
- Now runs only a selected subset of all configurations (all STM32F072/L073)
- Added a src_filter to the cloudsolar_03 since L073 does not have CAN.
  Maybe there is a better way to do this. Also added libignore for USB
  to this environment.
- Added memory.map to .gitignore

* STML0 support improved + small changes

- STM32L0 now widely supported: PWM signal generation, ADC via DMA and display via I2C are working

- Old files for USB support (only F0) included into repository, as files in original mbed repository don't compile.

- CAN bus support only for F0 (added header defines to allow compilation)

* Cell & Pack Config refactoring: First work on #13.
Reorganized battery init a bit to get a better idea of how to split things.
All known chemistries are now supported with safe values (please check the values).

Added data for NMC (aka "normal" LiIo cells such as most 18650)
A configuration now declares itself to be valid or not after battery_init.

BAT_TYPE_NONE (formerly BAT_TYPE_DEFAULT, which equals 0) will not pass check
and thus is an invalid configuration, as a result an unconfigured
battery_t struct will not be considered valid by accident.

We should not continue to start normal operation if a battery configuration is not valid.
However, this is not yet implemented.

Also slightly changed interface to battery_init, now we pass the number of cells.

Moved the static pub_enabled into main.cpp to get ride of a ton of "unused static variable"
warnings.

* ThingSet moved to separate library

* Removed serious bug in PWM signal generation resulting in PWM with 0% duty cycle

* LED control via PWM for STM32L0 board added

* Gets rid of USB deprecated warnings in application code
This simply disables any warning regarding the use
of deprecated internals in mbed for now.
Since the "new" USBDevice code does not run on F0 or L0, we use old
one which works but generates warnings a lot.
If they ever remove the deprecated interface, we'll know sure enough
since then code will no longer compile.

* More battery init refactoring

In addition to the mandatory arguments cell type, number in series and capacity,
the code now accepts a partially configure battery_t structure (you provide
various voltage levels and charge currents) for Lithium based cells, checks the configuration values for sanity
and tries to adjust if outside valid operational limits. The defaults try
to balance between charging stress and capacity loss.
Charge is by default to about 90% maximum full charge, and discharge stops around
20%-30%.

For lead acid cells all voltage levels and currents are set / calculated based
on the mandatory parameters, no configuration of voltage levels possible.

We may change that, but I don't have enough no knowledge about valid ranges
etc.

I added a high voltage lithium chemistry for cells which have typically
4.35 voltage limit (vs. 4.2 normally).

* Added user configuration for battery and system operation mode
Copy the most relevant template to config.cpp and then compile.
config.cpp is intentionally not part of the git managed source code
since it represents the user specific configuration part
which varies across different firmware builds.

* Turn off MBED Deprecated Warning for Old USB Stack attempt 2
This time cross platform compatible...
And also fix the travis build issue

* Boost mode added and first updates for timer-based DC/DC control

- system_mode now distinguishes between MPPT_BOOST and MPPT_BUCK
- new function system_control() which does all important and fast control
stuff necessary for the DC/DC (will be included into interrupt in the
future)
- small correction in _dcdc_output_control() algorithm after test with e-bike
battery solar charging

* Naming of structs and enums adjusted

* Documentation amended and separate docs folder created.

* UNIT_TEST defines removed

* Timer for DC/DC control implemented, ADC timer updated

* Files restructured / renamed

- config.h is now pcb.h and contains only hardware-specific settings
- anything which communicates to the outside world (display, serial interface, etc)
  is now renamed to more generic "interface" instead of "output" and "communication".
  Use interface_<DEVICE>.cpp for implementations of specific interfaces.

* Updates in user configuration and interfaces

- Battery configuration can now be adjusted in battery_init_user in config.cpp
- New function battery_update_settings implemented to check new battery configuration for plausibility (also needed for later user-configuration via serial interface)
- Templates for GSM and LoRa interfaces created
- Restructuring of main to allow different interface configurations

* Travis CI adjusted to new config.h

* Load output templates added

* ThingSet library updated, interface processing updated, publication functions added

* Load output implementation updated and moved to load.cpp/h

* Energy calculation updated and eTotal changed to uint32_t

* Update firmware.md

* Issue monitor_speed typing mistake

We found a typing issue: "monitor_speed" is mistyped as "monitor_port".

* Major updates of recent months
2019-02-16 09:53:36 +01:00