Commit Graph
52 Commits
Author SHA1 Message Date
Martin Jaeger 14249492a3 Improve full charge detection and topping control
The battery is only full if the topping voltage is still reached AND the
current is below cut-off threshold at the same time. This was not always
detected correctly with previous 2s target voltage monitoring interval.

In addition to that, a new timer was introduced to count seconds at target
voltage and improve full charge detection due to timeout.
2020-02-10 12:47:32 +00:00
Martin Jaeger 5f1d76ef74 Dedicated setup.cpp to clean up main.cpp
Also includes update of timestamp calculation in Zephyr.
2020-02-08 11:08:58 +01:00
Martin Jaeger 43f90eea7c Move voltage control parameters to DcBus class
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
2020-02-07 12:03:25 +01:00
Martin Jaeger a7d6dbc3b5 Let PWM switch class inherit from PowerPort
First step of unifying different ports connected to one bus. At a later
step, also the load and charger classes should inherit from PowerPort
class to make overall charge controller structure more clean.
2020-02-07 12:00:59 +01:00
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger 05292c12ba ADC & DMA renamed to DAQ (data acquisition) 2020-01-27 15:13:53 +01:00
Martin Jaeger 41b4607cc7 Fix additional bug in load unit-test 2020-01-20 15:22:21 +01:00
Martin Jaeger 69747a588d Fix initialization bug in load unit-test 2020-01-20 10:41:48 +01:00
Martin Jaeger 16ca793bb3 Port configuration based on Kconfig implemented 2020-01-06 19:16:44 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger 3f89943edf ThingSet interfaces merged with Ext interfaces 2019-12-20 10:43:51 +01:00
Martin Jaeger 62f2f1978c UEXT and ThingSet code moved to ext folder 2019-12-20 10:38:31 +01:00
Martin Jaeger 74b765e801 Trailing white spaces removed 2019-11-21 07:44:15 +01:00
Martin Jaeger 47954166be Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage
- Hysteresis for load overvoltage reconnect setpoint made configurable
- Added check for PWM switch MOSFET driver undervoltage
2019-11-11 11:38:34 +01:00
Martin Jaeger f254c77ab6 Refactoring of load control and state machine
- State machine and control merged to one function
- Load states marked as deprecated, global error flags used instead
- Reduced duplicated code and made load control function easier to read
2019-11-11 09:35:26 +01:00
hogthrob d1ff837c5e Overvoltage limit overflow fix (#80)
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.

Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
2019-11-10 17:55:43 +01:00
hogthrob ba7d379225 Refactored adc_dma.cpp for readability (#76)
- replaced the lengthy adc value formulas with respective functions
  to ease reading
- removed unecessary casts for alert callbacks
- added static to the internal global variables in order to hide them from the
  other compilation units
2019-11-09 23:13:00 +01:00
Martin Jaeger 328215dc8e Load overvoltage detection corrected and error flag comments added 2019-11-07 16:00:51 +01:00
Martin Jaeger 5e3181f5e5 Distinguishing between OV and UV alerts, inhibit added
- During overvoltage alerts, only power sources (PWM switch and DC/DC are
  switched off), undervoltage only switches load off
- Alert inhibit added to prevent switching off during PWM switch startup
2019-11-05 18:43:33 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
Martin Jaeger 7412b11002 ADC filtering in separate function + unit-tests 2019-11-04 18:02:43 +01:00
hogthrob bec02cb25b Switched to use power of 2 error numbers (#72)
In addition to the normal error flags we now have
ERR_ANY_ERROR which may be used to clear all errors
at once or to use in has_error to see if there is any error flag set.
2019-11-04 09:19:06 +01:00
hogthrob fd474e5350 Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code
completion), no performance loss due to inlining.
2019-11-02 08:22:00 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00
Martin Jaeger cb0c3c8135 USB output state machine improved (see #69) 2019-10-31 16:32:03 +01:00
Martin Jaeger b98461fee4 Load off for internal overtemp implemented 2019-10-31 12:07:21 +01:00
Martin Jaeger b0e265f3e9 NTC on PCB not used as battery temperature anymore
- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
2019-10-31 11:22:03 +01:00
Martin Jaeger 5b4df98656 Load protection improvements
- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
  battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
2019-10-30 17:31:16 +01:00
Martin Jaeger a7239fa9bb Enabled all warnings for unit-test builds 2019-10-24 16:10:35 +02:00
Martin Jaeger 68ae3227cc Discharge and load output control improvements
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added
2019-10-24 16:04:32 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger 515b098e85 Passing of bat voltage and current limits to other ports updated 2019-10-23 07:29:05 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger a89ac7ff4b Fixing not working references to bat/solar ports in data_objects 2019-10-21 18:00:27 +02:00
Martin Jaeger 8558cef9cb PWM switch also implemented as class 2019-10-20 22:01:45 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger 6c3885e5d0 Log unit-tests added 2019-10-16 21:32:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 0545131a99 Equalization charging phase added 2019-10-16 10:02:27 +02:00
Martin Jaeger 25e469516c DC/DC control functions cleaned up 2019-10-15 14:00:20 +02:00
Martin Jaeger ae51d7a0d7 Unit tests for DC/DC control added 2019-10-15 13:59:48 +02:00
Martin Jaeger e7317ae1d8 DC bus and terminal naming improved
- DcBus representing actual screw terminals renamed
- Internal DC bus at DC/DC low voltage side added for correct DC/DC control
- DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed.
- Unit tests updated

DC/DC control needs further improvements to make use of the changes
2019-10-15 13:57:23 +02:00
Martin Jaeger cb206b6864 DC/DC startup check reworked and unit-tests added 2019-10-15 13:54:05 +02:00
hogthrob 6d56003c8c Unified half bridge timer handling (#53)
* As much as possible code is shared between both timer abstractions.
* Unit tests added to main implementation file (stub removed)
2019-10-15 10:34:53 +02:00
Martin Jaeger c968a6bb8a Structs renamed for new coding style (closes #42) 2019-08-08 10:16:16 +02:00
Martin Jaeger 690e204a16 Solar, bat and load power added to data objects 2019-06-18 17:04:33 +02:00
Martin Jaeger dec36143dd 12V/24V detection added and bat_charger restructured 2019-05-23 22:16:41 +02:00
Martin Jaeger 7c75548193 DC bus type introduced and unit tests added 2019-05-07 18:56:04 +02:00
Martin Jaeger d9f7103e97 Starting test-driven development (TDD) with Unity
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory
2019-05-04 11:31:37 +02:00