From cf5366c2babf15043240649eab2e4c547a687927 Mon Sep 17 00:00:00 2001 From: Martin Jaeger <17674105+martinjaeger@users.noreply.github.com> Date: Thu, 11 Jul 2019 13:11:34 +0200 Subject: [PATCH] Fix usable_capacity estimation to prevent wrong values before first full charge --- src/bat_charger.cpp | 14 ++++++++++---- src/bat_charger.h | 1 + 2 files changed, 11 insertions(+), 4 deletions(-) diff --git a/src/bat_charger.cpp b/src/bat_charger.cpp index 861642b..aeffbf1 100644 --- a/src/bat_charger.cpp +++ b/src/bat_charger.cpp @@ -213,6 +213,7 @@ void charger_init(charger_t *charger) charger->num_batteries = 1; // initialize with only one battery in series charger->soh = 100; // assume new battery charger->bat_temperature = 25.0; + charger->first_full_charge_reached = false; } void charger_detect_num_batteries(charger_t *charger, battery_conf_t *bat, dc_bus_t *bus) @@ -267,16 +268,19 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c { //printf("time_state_change = %d, time = %d, v_bat = %f, i_bat = %f\n", charger->time_state_changed, time(NULL), voltage, current); - // Load management - // battery port input state (i.e. battery discharging direction) defines load state + // load output state is defined by battery bus dis_allowed flag if (bus->dis_allowed == true && bus->voltage < (bat_conf->voltage_load_disconnect - bus->current * bus->dis_droop_res) * charger->num_batteries) { + // low state of charge bus->dis_allowed = false; charger->num_deep_discharges++; if (charger->usable_capacity < 0.1) { - charger->usable_capacity = charger->discharged_Ah; + // reset to measured value if discharged the first time + if (charger->first_full_charge_reached) { + charger->usable_capacity = charger->discharged_Ah; + } } else { // slowly adapt new measurements with low-pass filter charger->usable_capacity = 0.8 * charger->usable_capacity + 0.2 * charger->discharged_Ah; @@ -289,6 +293,7 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c && (charger->bat_temperature > bat_conf->discharge_temp_max || charger->bat_temperature < bat_conf->discharge_temp_min)) { + // temperature limits exceeded bus->dis_allowed = false; } @@ -299,7 +304,7 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c bus->dis_allowed = true; } - // check battery temperature + // check battery temperature for charging direction if (charger->bat_temperature > bat_conf->charge_temp_max || charger->bat_temperature < bat_conf->charge_temp_min) { @@ -348,6 +353,7 @@ void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *c charger->full = true; charger->num_full_charges++; charger->discharged_Ah = 0; // reset coulomb counter + charger->first_full_charge_reached = true; /*if (bat_conf->equalization_enabled) { // TODO: additional conditions! diff --git a/src/bat_charger.h b/src/bat_charger.h index 3993749..db1aaeb 100644 --- a/src/bat_charger.h +++ b/src/bat_charger.h @@ -250,6 +250,7 @@ typedef struct int time_voltage_limit_reached; ///< Last time the CV limit was reached bool full; ///< Flag to indicate if battery was fully charged + bool first_full_charge_reached; ///< Set to true if battery was fully charged at least once (necessary for proper capacity estimation) } charger_t;