Load off for internal overtemp implemented

This commit is contained in:
Martin Jaeger
2019-10-31 12:07:21 +01:00
parent b1a7babaff
commit b98461fee4
5 changed files with 55 additions and 8 deletions
+9
View File
@@ -175,6 +175,15 @@ void update_measurements()
uint16_t adcval = (adc_filtered[ADC_POS_TEMP_MCU] >> (4 + ADC_FILTER_CONST)) * vcc / VREFINT_VALUE;
internal_temp = (TSENSE_CAL2_VALUE - TSENSE_CAL1_VALUE) /
(TSENSE_CAL2 - TSENSE_CAL1) * (adcval - TSENSE_CAL1) + TSENSE_CAL1_VALUE;
if (internal_temp > 80) {
log_data.error_flags |= 1U << ERR_INT_OVERTEMP;
}
else if (internal_temp < 70 && (log_data.error_flags & (1U << ERR_INT_OVERTEMP))) {
// remove error flag with hysteresis of 10°C
log_data.error_flags &= ~(1U << ERR_INT_OVERTEMP);
}
// else: keep previous setting
}
#ifndef UNIT_TEST