Improve Kconfig and docs for battery type setup
This commit is contained in:
@@ -149,6 +149,7 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa
|
||||
break;
|
||||
|
||||
case BAT_TYPE_CUSTOM:
|
||||
#ifdef CONFIG_BAT_TYPE_CUSTOM
|
||||
bat->voltage_absolute_max = 0.001F *
|
||||
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV);
|
||||
|
||||
@@ -198,6 +199,9 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa
|
||||
bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN;
|
||||
bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX;
|
||||
bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN;
|
||||
#else
|
||||
LOG_ERR("Custom battery type cannot be initialized at runtime.");
|
||||
#endif
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue