Improve Kconfig and docs for battery type setup
This commit is contained in:
@@ -136,9 +136,22 @@ In order to overwrite the default devicetree specification, so-called overlays c
|
||||
|
||||
For configuration of the application-specific features, Zephyr uses the [Kconfig system](https://docs.zephyrproject.org/latest/guides/kconfig/index.html).
|
||||
|
||||
The configuration can be changed using `west build -t menuconfig` command or manually by changing the prj.conf file.
|
||||
The configuration can be changed using `west build -t menuconfig` command or manually by changing the prj.conf file (see `Kconfig` file for possible options).
|
||||
|
||||
Similar to DTS overlays, the Kconfig can also be customized for each board. Copy the default `prj.conf` to a file `prj_board_name.conf` to use this file instead of `prj.conf`. Please not that, in contrast to overlays, the board-specific Kconfig files are not **added** to the default `prj.conf`, but they **replace** the default configuration instead.
|
||||
Similar to DTS overlays, Kconfig can also be customized per board. Create a folder `zephyr/boards` and a file `board_name.conf` in that folder. The configuration from this file will be merged with the `prj.conf` automatically.
|
||||
|
||||
#### Change the battery type
|
||||
|
||||
By default, the charge controller is configured for maintainance-free VRLA gel battery (`CONFIG_BAT_TYPE_GEL`). Possible other pre-defined options are `CONFIG_BAT_TYPE_FLOODED`, `CONFIG_BAT_TYPE_AGM`, `CONFIG_BAT_TYPE_LFP`, `CONFIG_BAT_TYPE_NMC` and `CONFIG_BAT_TYPE_NMC_HV`.
|
||||
|
||||
The number of cells is automatically selected by Kconfig to get 12V nominal voltage. It can also be manually specified via `CONFIG_BAT_NUM_CELLS`.
|
||||
|
||||
To compile the firmware with default settings for 12V LiFePO4 batteries, add the following to `prj.conf` or the board-specific `.conf` file:
|
||||
|
||||
```
|
||||
CONFIG_BAT_TYPE_LFP=y
|
||||
CONFIG_BAT_NUM_CELLS=4
|
||||
```
|
||||
|
||||
### Custom functions (separate C/C++ files)
|
||||
|
||||
|
||||
@@ -149,6 +149,7 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa
|
||||
break;
|
||||
|
||||
case BAT_TYPE_CUSTOM:
|
||||
#ifdef CONFIG_BAT_TYPE_CUSTOM
|
||||
bat->voltage_absolute_max = 0.001F *
|
||||
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV);
|
||||
|
||||
@@ -198,6 +199,9 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa
|
||||
bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN;
|
||||
bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX;
|
||||
bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN;
|
||||
#else
|
||||
LOG_ERR("Custom battery type cannot be initialized at runtime.");
|
||||
#endif
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
+32
-30
@@ -87,6 +87,13 @@ endchoice
|
||||
|
||||
menu "Battery default settings"
|
||||
|
||||
config BAT_CAPACITY_AH
|
||||
int "Battery nominal capacity in Ah"
|
||||
range 10 1000
|
||||
default 50
|
||||
help
|
||||
Nominal battery capacity or sum of parallel cells capacity
|
||||
|
||||
choice
|
||||
prompt "Battery type"
|
||||
default BAT_TYPE_GEL
|
||||
@@ -128,15 +135,8 @@ config BAT_TYPE
|
||||
default 5 if BAT_TYPE_NMC
|
||||
default 6 if BAT_TYPE_NMC_HV
|
||||
|
||||
config BAT_CAPACITY_AH
|
||||
int "Battery nominal capacity in Ah"
|
||||
range 10 200
|
||||
default 50
|
||||
help
|
||||
Nominal battery capacity or sum of parallel cells capacity
|
||||
|
||||
config BAT_NUM_CELLS
|
||||
int "Number of cells for single battery" if BAT_TYPE_CUSTOM
|
||||
int "Number of cells for single battery"
|
||||
default 6 if BAT_TYPE_FLOODED || BAT_TYPE_GEL || BAT_TYPE_AGM
|
||||
default 4 if BAT_TYPE_LFP
|
||||
default 3 if BAT_TYPE_NMC || BAT_TYPE_NMC_HV
|
||||
@@ -154,67 +154,68 @@ config BAT_NUM_CELLS
|
||||
is not exceeded.
|
||||
|
||||
menu "Custom cell-level settings"
|
||||
depends on BAT_TYPE_CUSTOM
|
||||
|
||||
config CELL_ABS_MAX_VOLTAGE_MV
|
||||
int "Absolute maximum voltage (mV)" if BAT_TYPE_CUSTOM
|
||||
int "Absolute maximum voltage (mV)"
|
||||
default 2450
|
||||
help
|
||||
Above this voltage the battery or loads might get damaged.
|
||||
|
||||
config CELL_TOPPING_VOLTAGE_MV
|
||||
int "Topping voltage (mV)" if BAT_TYPE_CUSTOM
|
||||
int "Topping voltage (mV)"
|
||||
default 2400
|
||||
help
|
||||
Charger target voltage, switching from CC to CV at this voltage threshold.
|
||||
|
||||
config CELL_RECHARGE_VOLTAGE_MV
|
||||
int "Recharge voltage (mV)" if BAT_TYPE_CUSTOM
|
||||
int "Recharge voltage (mV)"
|
||||
default 2300
|
||||
help
|
||||
Start charging again if voltage of fully charged battery drops below this threshold.
|
||||
|
||||
config CELL_RECONNECT_VOLTAGE_MV
|
||||
int "Load reconnect cell voltage (mV)" if BAT_TYPE_CUSTOM
|
||||
int "Load reconnect cell voltage (mV)"
|
||||
default 2100
|
||||
help
|
||||
Re-enable the load only after charged beyond this value.
|
||||
|
||||
config CELL_DISCONNECT_VOLTAGE_MV
|
||||
int "Load disconnect cell voltage (mV)" if BAT_TYPE_CUSTOM
|
||||
int "Load disconnect cell voltage (mV)"
|
||||
default 1950
|
||||
help
|
||||
Load output is disabled if battery voltage is below this threshold.
|
||||
|
||||
config CELL_ABS_MIN_VOLTAGE_MV
|
||||
int "Topping voltage (mV)" if BAT_TYPE_CUSTOM
|
||||
int "Topping voltage (mV)"
|
||||
default 1600
|
||||
help
|
||||
Below this voltage the battery is considered damaged.
|
||||
|
||||
config CELL_OCV_FULL_MV
|
||||
int "OCV full cell (mV)" if BAT_TYPE_CUSTOM
|
||||
int "OCV full cell (mV)"
|
||||
default 2150
|
||||
help
|
||||
Voltages during idle (no charging/discharging current)
|
||||
|
||||
config CELL_OCV_EMPTY_MV
|
||||
int "OCV empty cell (mV)" if BAT_TYPE_CUSTOM
|
||||
int "OCV empty cell (mV)"
|
||||
default 1900
|
||||
help
|
||||
Voltages during idle (no charging/discharging current)
|
||||
|
||||
config CELL_TRICKLE
|
||||
bool "Enable trickle charging phase" if BAT_TYPE_CUSTOM
|
||||
bool "Enable trickle charging phase"
|
||||
default y
|
||||
|
||||
config CELL_TRICKLE_VOLTAGE_MV
|
||||
int "Trickle charging cell voltage (mV)" if BAT_TYPE_CUSTOM && CELL_TRICKLE
|
||||
int "Trickle charging cell voltage (mV)" if CELL_TRICKLE
|
||||
default 2300
|
||||
help
|
||||
Charger target voltage for trickle charging of lead-acid batteries
|
||||
|
||||
config CELL_TRICKLE_RECHARGE_TIME
|
||||
int "Trickle recharge time (s)" if BAT_TYPE_CUSTOM && CELL_TRICKLE
|
||||
int "Trickle recharge time (s)" if CELL_TRICKLE
|
||||
default 1800
|
||||
help
|
||||
If the trickle voltage is not reached anymore (e.g. because of lack of solar
|
||||
@@ -222,68 +223,69 @@ config CELL_TRICKLE_RECHARGE_TIME
|
||||
into CC/bulk charging mode.
|
||||
|
||||
config CELL_EQUALIZATION
|
||||
bool "Enable equalization phase" if BAT_TYPE_CUSTOM
|
||||
bool "Enable equalization phase"
|
||||
default n
|
||||
help
|
||||
Enable for flooded batteries only.
|
||||
|
||||
config CELL_EQUALIZATION_VOLTAGE_MV
|
||||
int "Equalization phase cell voltage (mV)" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION
|
||||
int "Equalization phase cell voltage (mV)" if CELL_EQUALIZATION
|
||||
default 2450
|
||||
help
|
||||
Charger target voltage for equalization charging of lead-acid batteries
|
||||
|
||||
config CELL_EQUALIZATION_DURATION
|
||||
int "Equalization duration (seconds)" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION
|
||||
int "Equalization duration (seconds)" if CELL_EQUALIZATION
|
||||
default 3600
|
||||
help
|
||||
After this time, equalization charging is stopped.
|
||||
|
||||
config CELL_EQUALIZATION_TRIGGER_DAYS
|
||||
int "Equalization time trigger (days)" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION
|
||||
int "Equalization time trigger (days)" if CELL_EQUALIZATION
|
||||
default 60
|
||||
help
|
||||
After passing specified amount of days, an equalization charge is triggered.
|
||||
|
||||
config CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES
|
||||
int "Equalization deep cycle count trigger" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION
|
||||
int "Equalization deep cycle count trigger" if CELL_EQUALIZATION
|
||||
default 10
|
||||
help
|
||||
After specified number of deep discharges, an equalization charge is triggered.
|
||||
|
||||
config CELL_TEMP_COMPENSATION_MV_K
|
||||
int "Cell voltage temperature compenstaion (mV/K)" if BAT_TYPE_CUSTOM
|
||||
int "Cell voltage temperature compenstaion (mV/K)"
|
||||
range -5 0
|
||||
default -3
|
||||
help
|
||||
Suggested value: -3 mV/K/cell for lead-acid batteries, 0 for Li-ion batteries
|
||||
|
||||
config CELL_INTERNAL_RESISTANCE_MOHM
|
||||
int "Cell internal resistance (mOhm)" if BAT_TYPE_CUSTOM
|
||||
int "Cell internal resistance (mOhm)"
|
||||
range 1 30
|
||||
default 5
|
||||
|
||||
endmenu # Custom cell-level settings
|
||||
|
||||
menu "Custom temperature settings"
|
||||
depends on BAT_TYPE_CUSTOM
|
||||
|
||||
config BAT_CHARGE_TEMP_MAX
|
||||
int "Maximum charge temperature (°C)" if BAT_TYPE_CUSTOM
|
||||
int "Maximum charge temperature (°C)"
|
||||
range 0 60
|
||||
default 50
|
||||
|
||||
config BAT_CHARGE_TEMP_MIN
|
||||
int "Minimum charge temperature (°C)" if BAT_TYPE_CUSTOM
|
||||
int "Minimum charge temperature (°C)"
|
||||
range -10 20
|
||||
default 0
|
||||
|
||||
config BAT_DISCHARGE_TEMP_MAX
|
||||
int "Maximum discharge temperature (°C)" if BAT_TYPE_CUSTOM
|
||||
int "Maximum discharge temperature (°C)"
|
||||
range 0 60
|
||||
default 50
|
||||
|
||||
config BAT_DISCHARGE_TEMP_MIN
|
||||
int "Minimum discharge temperature (°C)" if BAT_TYPE_CUSTOM
|
||||
int "Minimum discharge temperature (°C)"
|
||||
range -20 20
|
||||
default -10
|
||||
|
||||
|
||||