diff --git a/README.md b/README.md index f6f20ab..968ca48 100644 --- a/README.md +++ b/README.md @@ -136,9 +136,22 @@ In order to overwrite the default devicetree specification, so-called overlays c For configuration of the application-specific features, Zephyr uses the [Kconfig system](https://docs.zephyrproject.org/latest/guides/kconfig/index.html). -The configuration can be changed using `west build -t menuconfig` command or manually by changing the prj.conf file. +The configuration can be changed using `west build -t menuconfig` command or manually by changing the prj.conf file (see `Kconfig` file for possible options). -Similar to DTS overlays, the Kconfig can also be customized for each board. Copy the default `prj.conf` to a file `prj_board_name.conf` to use this file instead of `prj.conf`. Please not that, in contrast to overlays, the board-specific Kconfig files are not **added** to the default `prj.conf`, but they **replace** the default configuration instead. +Similar to DTS overlays, Kconfig can also be customized per board. Create a folder `zephyr/boards` and a file `board_name.conf` in that folder. The configuration from this file will be merged with the `prj.conf` automatically. + +#### Change the battery type + +By default, the charge controller is configured for maintainance-free VRLA gel battery (`CONFIG_BAT_TYPE_GEL`). Possible other pre-defined options are `CONFIG_BAT_TYPE_FLOODED`, `CONFIG_BAT_TYPE_AGM`, `CONFIG_BAT_TYPE_LFP`, `CONFIG_BAT_TYPE_NMC` and `CONFIG_BAT_TYPE_NMC_HV`. + +The number of cells is automatically selected by Kconfig to get 12V nominal voltage. It can also be manually specified via `CONFIG_BAT_NUM_CELLS`. + +To compile the firmware with default settings for 12V LiFePO4 batteries, add the following to `prj.conf` or the board-specific `.conf` file: + +``` +CONFIG_BAT_TYPE_LFP=y +CONFIG_BAT_NUM_CELLS=4 +``` ### Custom functions (separate C/C++ files) diff --git a/src/bat_charger.cpp b/src/bat_charger.cpp index 01823d0..aa60f94 100644 --- a/src/bat_charger.cpp +++ b/src/bat_charger.cpp @@ -149,6 +149,7 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa break; case BAT_TYPE_CUSTOM: +#ifdef CONFIG_BAT_TYPE_CUSTOM bat->voltage_absolute_max = 0.001F * static_cast(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV); @@ -198,6 +199,9 @@ void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capa bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN; bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX; bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN; +#else + LOG_ERR("Custom battery type cannot be initialized at runtime."); +#endif break; } } diff --git a/zephyr/Kconfig b/zephyr/Kconfig index 6c582de..e9a377c 100644 --- a/zephyr/Kconfig +++ b/zephyr/Kconfig @@ -87,6 +87,13 @@ endchoice menu "Battery default settings" +config BAT_CAPACITY_AH + int "Battery nominal capacity in Ah" + range 10 1000 + default 50 + help + Nominal battery capacity or sum of parallel cells capacity + choice prompt "Battery type" default BAT_TYPE_GEL @@ -128,15 +135,8 @@ config BAT_TYPE default 5 if BAT_TYPE_NMC default 6 if BAT_TYPE_NMC_HV -config BAT_CAPACITY_AH - int "Battery nominal capacity in Ah" - range 10 200 - default 50 - help - Nominal battery capacity or sum of parallel cells capacity - config BAT_NUM_CELLS - int "Number of cells for single battery" if BAT_TYPE_CUSTOM + int "Number of cells for single battery" default 6 if BAT_TYPE_FLOODED || BAT_TYPE_GEL || BAT_TYPE_AGM default 4 if BAT_TYPE_LFP default 3 if BAT_TYPE_NMC || BAT_TYPE_NMC_HV @@ -154,67 +154,68 @@ config BAT_NUM_CELLS is not exceeded. menu "Custom cell-level settings" + depends on BAT_TYPE_CUSTOM config CELL_ABS_MAX_VOLTAGE_MV - int "Absolute maximum voltage (mV)" if BAT_TYPE_CUSTOM + int "Absolute maximum voltage (mV)" default 2450 help Above this voltage the battery or loads might get damaged. config CELL_TOPPING_VOLTAGE_MV - int "Topping voltage (mV)" if BAT_TYPE_CUSTOM + int "Topping voltage (mV)" default 2400 help Charger target voltage, switching from CC to CV at this voltage threshold. config CELL_RECHARGE_VOLTAGE_MV - int "Recharge voltage (mV)" if BAT_TYPE_CUSTOM + int "Recharge voltage (mV)" default 2300 help Start charging again if voltage of fully charged battery drops below this threshold. config CELL_RECONNECT_VOLTAGE_MV - int "Load reconnect cell voltage (mV)" if BAT_TYPE_CUSTOM + int "Load reconnect cell voltage (mV)" default 2100 help Re-enable the load only after charged beyond this value. config CELL_DISCONNECT_VOLTAGE_MV - int "Load disconnect cell voltage (mV)" if BAT_TYPE_CUSTOM + int "Load disconnect cell voltage (mV)" default 1950 help Load output is disabled if battery voltage is below this threshold. config CELL_ABS_MIN_VOLTAGE_MV - int "Topping voltage (mV)" if BAT_TYPE_CUSTOM + int "Topping voltage (mV)" default 1600 help Below this voltage the battery is considered damaged. config CELL_OCV_FULL_MV - int "OCV full cell (mV)" if BAT_TYPE_CUSTOM + int "OCV full cell (mV)" default 2150 help Voltages during idle (no charging/discharging current) config CELL_OCV_EMPTY_MV - int "OCV empty cell (mV)" if BAT_TYPE_CUSTOM + int "OCV empty cell (mV)" default 1900 help Voltages during idle (no charging/discharging current) config CELL_TRICKLE - bool "Enable trickle charging phase" if BAT_TYPE_CUSTOM + bool "Enable trickle charging phase" default y config CELL_TRICKLE_VOLTAGE_MV - int "Trickle charging cell voltage (mV)" if BAT_TYPE_CUSTOM && CELL_TRICKLE + int "Trickle charging cell voltage (mV)" if CELL_TRICKLE default 2300 help Charger target voltage for trickle charging of lead-acid batteries config CELL_TRICKLE_RECHARGE_TIME - int "Trickle recharge time (s)" if BAT_TYPE_CUSTOM && CELL_TRICKLE + int "Trickle recharge time (s)" if CELL_TRICKLE default 1800 help If the trickle voltage is not reached anymore (e.g. because of lack of solar @@ -222,68 +223,69 @@ config CELL_TRICKLE_RECHARGE_TIME into CC/bulk charging mode. config CELL_EQUALIZATION - bool "Enable equalization phase" if BAT_TYPE_CUSTOM + bool "Enable equalization phase" default n help Enable for flooded batteries only. config CELL_EQUALIZATION_VOLTAGE_MV - int "Equalization phase cell voltage (mV)" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION + int "Equalization phase cell voltage (mV)" if CELL_EQUALIZATION default 2450 help Charger target voltage for equalization charging of lead-acid batteries config CELL_EQUALIZATION_DURATION - int "Equalization duration (seconds)" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION + int "Equalization duration (seconds)" if CELL_EQUALIZATION default 3600 help After this time, equalization charging is stopped. config CELL_EQUALIZATION_TRIGGER_DAYS - int "Equalization time trigger (days)" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION + int "Equalization time trigger (days)" if CELL_EQUALIZATION default 60 help After passing specified amount of days, an equalization charge is triggered. config CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES - int "Equalization deep cycle count trigger" if BAT_TYPE_CUSTOM && CELL_EQUALIZATION + int "Equalization deep cycle count trigger" if CELL_EQUALIZATION default 10 help After specified number of deep discharges, an equalization charge is triggered. config CELL_TEMP_COMPENSATION_MV_K - int "Cell voltage temperature compenstaion (mV/K)" if BAT_TYPE_CUSTOM + int "Cell voltage temperature compenstaion (mV/K)" range -5 0 default -3 help Suggested value: -3 mV/K/cell for lead-acid batteries, 0 for Li-ion batteries config CELL_INTERNAL_RESISTANCE_MOHM - int "Cell internal resistance (mOhm)" if BAT_TYPE_CUSTOM + int "Cell internal resistance (mOhm)" range 1 30 default 5 endmenu # Custom cell-level settings menu "Custom temperature settings" + depends on BAT_TYPE_CUSTOM config BAT_CHARGE_TEMP_MAX - int "Maximum charge temperature (°C)" if BAT_TYPE_CUSTOM + int "Maximum charge temperature (°C)" range 0 60 default 50 config BAT_CHARGE_TEMP_MIN - int "Minimum charge temperature (°C)" if BAT_TYPE_CUSTOM + int "Minimum charge temperature (°C)" range -10 20 default 0 config BAT_DISCHARGE_TEMP_MAX - int "Maximum discharge temperature (°C)" if BAT_TYPE_CUSTOM + int "Maximum discharge temperature (°C)" range 0 60 default 50 config BAT_DISCHARGE_TEMP_MIN - int "Minimum discharge temperature (°C)" if BAT_TYPE_CUSTOM + int "Minimum discharge temperature (°C)" range -20 20 default -10