Provide detailed log out for rejected battery configuration requests (#127)

It also gets rid of the duplication of code between the debug output
and the actual return value calculation by folding both into the same
loop.
This commit is contained in:
hogthrob
2022-01-25 12:56:47 +01:00
committed by GitHub
parent debb98e5a3
commit 2359a96bbe
+72 -28
View File
@@ -13,6 +13,7 @@ LOG_MODULE_REGISTER(bat_charger, CONFIG_BAT_LOG_LEVEL);
#include <math.h> // for fabs function
#include <stdio.h>
#include <functional>
#include "board.h"
#include "helper.h"
@@ -211,36 +212,79 @@ bool battery_conf_check(BatConf *bat_conf)
// - load_disconnect/reconnect hysteresis makes sense?
// - cutoff current not extremely low/high
// - capacity plausible
//
LOG_DBG("battery_conf_check: %d %d %d %d %d %d %d",
bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.6),
bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4),
bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1),
bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4),
bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0),
bat_conf->topping_cutoff_current > 0.01,
(bat_conf->float_enabled == false ||
(bat_conf->float_voltage < bat_conf->topping_voltage &&
bat_conf->float_voltage > bat_conf->load_disconnect_voltage))
);
struct condition {
std::function<bool()> func;
const char *text;
};
return (
bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.4) &&
bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4) &&
bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1) &&
bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4) &&
// max. 10% drop
bat_conf->internal_resistance < bat_conf->load_disconnect_voltage * 0.1 /
DISCHARGE_CURRENT_MAX &&
// max. 3% loss
bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX &&
// C/10 or lower current cutoff allowed
bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0) &&
bat_conf->topping_cutoff_current > 0.01 &&
(bat_conf->float_enabled == false ||
(bat_conf->float_voltage < bat_conf->topping_voltage &&
bat_conf->float_voltage > bat_conf->load_disconnect_voltage))
);
const condition conditions[] = {
{.func =
[bat_conf]() {
return bat_conf->load_reconnect_voltage >
(bat_conf->load_disconnect_voltage + 0.4);
},
.text = "Load Reconnect Voltage must be higher than Load Disconnect Voltage + 0.4"},
{.func =
[bat_conf]() {
return bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4);
},
.text = "Recharge Voltage must be lower than Topping Voltage - 0.4"},
{.func =
[bat_conf]() {
return bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1);
},
.text = "Recharge Voltage must be higher than Load Disconnect Voltage + 1.0"},
{.func =
[bat_conf]() {
return bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4);
},
.text = "Load Disconnecct Voltage must be higher than Absolute Min Voltage + 0.4"},
{.func =
[bat_conf]() {
return bat_conf->internal_resistance <
bat_conf->load_disconnect_voltage * 0.1 / DISCHARGE_CURRENT_MAX;
},
.text = "Internal Battery Resistance must not cause more than 10% drop at Max Discharge "
"Current"},
{.func =
[bat_conf]() {
return bat_conf->wire_resistance <
bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX;
},
.text = "Wire Resistances must not cause more than 3% drop at Max Discharge Current"},
{.func =
[bat_conf]() {
return bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0);
},
.text = "Topping Cutoff Current must be less than 10% of Nominal Capacity (C/10)"},
{.func = [bat_conf]() { return bat_conf->topping_cutoff_current > 0.01; },
.text = "Topping Cutoff Current must be higher than 0.01A"},
{.func =
[bat_conf]() {
return bat_conf->float_enabled == false ||
bat_conf->float_voltage < bat_conf->topping_voltage;
},
.text = "Floating Charge Voltage must be lower than Topping Voltage"},
{.func =
[bat_conf]() {
return bat_conf->float_enabled == false ||
bat_conf->float_voltage > bat_conf->load_disconnect_voltage;
},
.text = "Floating Charge Voltage must be higher than Topping Voltage"},
};
bool result = true;
for (auto cond : conditions) {
bool cond_res = cond.func();
if (cond_res == false) {
LOG_ERR("battery_conf_check: failed condition '%s'", cond.text);
}
result = result && cond_res;
}
return result;
}
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)