From 2359a96bbeb2b7cf99dcd242f34a5d32b2ec494d Mon Sep 17 00:00:00 2001 From: hogthrob Date: Tue, 25 Jan 2022 12:56:47 +0100 Subject: [PATCH] Provide detailed log out for rejected battery configuration requests (#127) It also gets rid of the duplication of code between the debug output and the actual return value calculation by folding both into the same loop. --- app/src/bat_charger.cpp | 100 +++++++++++++++++++++++++++++----------- 1 file changed, 72 insertions(+), 28 deletions(-) diff --git a/app/src/bat_charger.cpp b/app/src/bat_charger.cpp index 125b4c7..9b604f4 100644 --- a/app/src/bat_charger.cpp +++ b/app/src/bat_charger.cpp @@ -13,6 +13,7 @@ LOG_MODULE_REGISTER(bat_charger, CONFIG_BAT_LOG_LEVEL); #include // for fabs function #include +#include #include "board.h" #include "helper.h" @@ -211,36 +212,79 @@ bool battery_conf_check(BatConf *bat_conf) // - load_disconnect/reconnect hysteresis makes sense? // - cutoff current not extremely low/high // - capacity plausible + // - LOG_DBG("battery_conf_check: %d %d %d %d %d %d %d", - bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.6), - bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4), - bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1), - bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4), - bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0), - bat_conf->topping_cutoff_current > 0.01, - (bat_conf->float_enabled == false || - (bat_conf->float_voltage < bat_conf->topping_voltage && - bat_conf->float_voltage > bat_conf->load_disconnect_voltage)) - ); + struct condition { + std::function func; + const char *text; + }; - return ( - bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.4) && - bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4) && - bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1) && - bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4) && - // max. 10% drop - bat_conf->internal_resistance < bat_conf->load_disconnect_voltage * 0.1 / - DISCHARGE_CURRENT_MAX && - // max. 3% loss - bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX && - // C/10 or lower current cutoff allowed - bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0) && - bat_conf->topping_cutoff_current > 0.01 && - (bat_conf->float_enabled == false || - (bat_conf->float_voltage < bat_conf->topping_voltage && - bat_conf->float_voltage > bat_conf->load_disconnect_voltage)) - ); + const condition conditions[] = { + {.func = + [bat_conf]() { + return bat_conf->load_reconnect_voltage > + (bat_conf->load_disconnect_voltage + 0.4); + }, + .text = "Load Reconnect Voltage must be higher than Load Disconnect Voltage + 0.4"}, + {.func = + [bat_conf]() { + return bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4); + }, + .text = "Recharge Voltage must be lower than Topping Voltage - 0.4"}, + {.func = + [bat_conf]() { + return bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1); + }, + .text = "Recharge Voltage must be higher than Load Disconnect Voltage + 1.0"}, + {.func = + [bat_conf]() { + return bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4); + }, + .text = "Load Disconnecct Voltage must be higher than Absolute Min Voltage + 0.4"}, + {.func = + [bat_conf]() { + return bat_conf->internal_resistance < + bat_conf->load_disconnect_voltage * 0.1 / DISCHARGE_CURRENT_MAX; + }, + .text = "Internal Battery Resistance must not cause more than 10% drop at Max Discharge " + "Current"}, + {.func = + [bat_conf]() { + return bat_conf->wire_resistance < + bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX; + }, + .text = "Wire Resistances must not cause more than 3% drop at Max Discharge Current"}, + {.func = + [bat_conf]() { + return bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0); + }, + .text = "Topping Cutoff Current must be less than 10% of Nominal Capacity (C/10)"}, + {.func = [bat_conf]() { return bat_conf->topping_cutoff_current > 0.01; }, + .text = "Topping Cutoff Current must be higher than 0.01A"}, + {.func = + [bat_conf]() { + return bat_conf->float_enabled == false || + bat_conf->float_voltage < bat_conf->topping_voltage; + }, + .text = "Floating Charge Voltage must be lower than Topping Voltage"}, + {.func = + [bat_conf]() { + return bat_conf->float_enabled == false || + bat_conf->float_voltage > bat_conf->load_disconnect_voltage; + }, + .text = "Floating Charge Voltage must be higher than Topping Voltage"}, + }; + + bool result = true; + for (auto cond : conditions) { + bool cond_res = cond.func(); + if (cond_res == false) { + LOG_ERR("battery_conf_check: failed condition '%s'", cond.text); + } + result = result && cond_res; + } + + return result; } void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)