/* LibreSolar charge controller firmware * Copyright (c) 2016-2019 Martin Jäger (www.libre.solar) * * Licensed under the Apache License, Version 2.0 (the "License"); * you may not use this file except in compliance with the License. * You may obtain a copy of the License at * * http://www.apache.org/licenses/LICENSE-2.0 * * Unless required by applicable law or agreed to in writing, software * distributed under the License is distributed on an "AS IS" BASIS, * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. * See the License for the specific language governing permissions and * limitations under the License. */ #include "bat_charger.h" #include "config.h" #include "pcb.h" #include "device_status.h" extern DeviceStatus dev_stat; #include // for fabs function #include #include void battery_conf_init(BatConf *bat, BatType type, int num_cells, float nominal_capacity) { bat->nominal_capacity = nominal_capacity; // 1C should be safe for all batteries bat->charge_current_max = bat->nominal_capacity; bat->discharge_current_max = bat->nominal_capacity; bat->time_limit_recharge = 60; // sec bat->topping_duration = 120*60; // sec bat->charge_temp_max = 50; bat->charge_temp_min = -10; bat->discharge_temp_max = 50; bat->discharge_temp_min = -10; switch (type) { case BAT_TYPE_FLOODED: case BAT_TYPE_AGM: case BAT_TYPE_GEL: bat->voltage_absolute_max = num_cells * 2.45; bat->topping_voltage = num_cells * 2.4; bat->voltage_recharge = num_cells * 2.3; // Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated) bat->voltage_load_disconnect = num_cells * 1.95; bat->voltage_load_reconnect = num_cells * 2.10; // assumption: Battery selection matching charge controller bat->internal_resistance = num_cells * (1.95 - 1.80) / LOAD_CURRENT_MAX; bat->voltage_absolute_min = num_cells * 1.6; // Voltages during idle (no charging/discharging current) bat->ocv_full = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.10 : 2.15); bat->ocv_empty = num_cells * 1.90; // https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery bat->topping_current_cutoff = bat->nominal_capacity * 0.04; // 3-5 % of C/1 bat->trickle_enabled = true; bat->trickle_recharge_time = 30*60; // Values as suggested in EN 62509:2011 bat->trickle_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3); // Enable for flooded batteries only, according to // https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only bat->equalization_enabled = false; // Values as suggested in EN 62509:2011 bat->equalization_voltage = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45); bat->equalization_duration = 60*60; bat->equalization_current_limit = (1.0 / 7.0) * bat->nominal_capacity; bat->equalization_trigger_days = 60; bat->equalization_trigger_deep_cycles = 10; bat->temperature_compensation = -0.003; // -3 mV/°C/cell break; case BAT_TYPE_LFP: bat->voltage_absolute_max = num_cells * 3.60; bat->topping_voltage = num_cells * 3.55; // CV voltage bat->voltage_recharge = num_cells * 3.35; bat->voltage_load_disconnect = num_cells * 3.0; bat->voltage_load_reconnect = num_cells * 3.15; // 5% voltage drop at max current bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX; bat->voltage_absolute_min = num_cells * 2.0; bat->ocv_full = num_cells * 3.4; // will give really nonlinear SOC calculation bat->ocv_empty = num_cells * 3.0; // because of flat OCV of LFP cells... // C/10 cut-off at end of CV phase by default bat->topping_current_cutoff = bat->nominal_capacity / 10; bat->trickle_enabled = false; bat->equalization_enabled = false; bat->temperature_compensation = 0.0; bat->charge_temp_min = 0; break; case BAT_TYPE_NMC: case BAT_TYPE_NMC_HV: bat->topping_voltage = num_cells * ((type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20); bat->voltage_absolute_max = bat->topping_voltage + num_cells * 0.05; bat->voltage_recharge = num_cells * 3.9; bat->voltage_load_disconnect = num_cells * 3.3; bat->voltage_load_reconnect = num_cells * 3.6; // 5% voltage drop at max current bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX; bat->voltage_absolute_min = num_cells * 2.5; bat->ocv_full = num_cells * 4.0; bat->ocv_empty = num_cells * 3.0; // C/10 cut-off at end of CV phase by default bat->topping_current_cutoff = bat->nominal_capacity / 10; bat->trickle_enabled = false; bat->equalization_enabled = false; bat->temperature_compensation = 0.0; bat->charge_temp_min = 0; break; case BAT_TYPE_NONE: break; } } // checks settings in bat_conf for plausibility bool battery_conf_check(BatConf *bat_conf) { // things to check: // - load_disconnect/reconnect hysteresis makes sense? // - cutoff current not extremely low/high // - capacity plausible /* printf("battery_conf_check: %d %d %d %d %d %d %d\n", bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.6), bat_conf->voltage_recharge < (bat_conf->voltage_max - 0.4), bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1), bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4), bat_conf->current_cutoff_CV < (bat_conf->nominal_capacity / 10.0), // C/10 or lower allowed bat_conf->current_cutoff_CV > 0.01, (bat_conf->trickle_enabled == false || (bat_conf->trickle_voltage < bat_conf->voltage_max && bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect)) ); */ return (bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) && bat_conf->voltage_recharge < (bat_conf->topping_voltage - 0.4) && bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) && bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) && // max. 10% drop bat_conf->internal_resistance < bat_conf->voltage_load_disconnect * 0.1 / LOAD_CURRENT_MAX && // max. 3% loss bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / LOAD_CURRENT_MAX && // C/10 or lower current cutoff allowed bat_conf->topping_current_cutoff < (bat_conf->nominal_capacity / 10.0) && bat_conf->topping_current_cutoff > 0.01 && (bat_conf->trickle_enabled == false || (bat_conf->trickle_voltage < bat_conf->topping_voltage && bat_conf->trickle_voltage > bat_conf->voltage_load_disconnect)) ); } void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger) { // TODO: stop DC/DC destination->topping_voltage = source->topping_voltage; destination->voltage_recharge = source->voltage_recharge; destination->voltage_load_reconnect = source->voltage_load_reconnect; destination->voltage_load_disconnect = source->voltage_load_disconnect; destination->voltage_absolute_max = source->voltage_absolute_max; destination->voltage_absolute_min = source->voltage_absolute_min; destination->charge_current_max = source->charge_current_max; destination->topping_current_cutoff = source->topping_current_cutoff; destination->topping_duration = source->topping_duration; destination->trickle_enabled = source->trickle_enabled; destination->trickle_voltage = source->trickle_voltage; destination->trickle_recharge_time = source->trickle_recharge_time; destination->charge_temp_max = source->charge_temp_max; destination->charge_temp_min = source->charge_temp_min; destination->discharge_temp_max = source->discharge_temp_max; destination->discharge_temp_min = source->discharge_temp_min; destination->temperature_compensation = source->temperature_compensation; destination->internal_resistance = source->internal_resistance; destination->wire_resistance = source->wire_resistance; // reset Ah counter and SOH if battery nominal capacity was changed if (destination->nominal_capacity != source->nominal_capacity) { destination->nominal_capacity = source->nominal_capacity; if (charger != NULL) { charger->discharged_Ah = 0; charger->usable_capacity = 0; charger->soh = 0; } } // TODO: // - update also DC/DC etc. (now this function only works at system startup) // - restart DC/DC } void Charger::detect_num_batteries(BatConf *bat) { if (port->voltage > bat->voltage_absolute_min * 2 && port->voltage < bat->voltage_absolute_max * 2) { num_batteries = 2; printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2); } else { printf("Detected single battery (%.2f V max)\n", bat->topping_voltage); } } void Charger::update_soc(BatConf *bat_conf) { static int soc_filtered = 0; // SOC / 100 for better filtering if (fabs(port->current) < 0.2) { int soc_new = (int)((port->voltage - bat_conf->ocv_empty) / (bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0); if (soc_new > 500 && soc_filtered == 0) { // bypass filter during initialization soc_filtered = soc_new; } else { // filtering to adjust SOC very slowly soc_filtered += (soc_new - soc_filtered) / 100; } if (soc_filtered > 10000) { soc_filtered = 10000; } else if (soc_filtered < 0) { soc_filtered = 0; } soc = soc_filtered / 100; } discharged_Ah += -port->current / 3600.0; // charged current is positive: change sign } void Charger::enter_state(int next_state) { //printf("Enter State: %d\n", next_state); time_state_changed = time(NULL); state = next_state; } void Charger::discharge_control(BatConf *bat_conf) { // load output state is defined by battery negative current limit if (port->neg_current_limit < 0) { // discharging currently allowed. see if that's still valid: if (port->voltage < num_batteries * (bat_conf->voltage_load_disconnect - port->current * port->neg_droop_res)) { // low state of charge port->neg_current_limit = 0; num_deep_discharges++; dev_stat.set_error(ERR_BAT_UNDERVOLTAGE); if (usable_capacity < 0.1) { // reset to measured value if discharged the first time if (first_full_charge_reached) { usable_capacity = discharged_Ah; } } else { // slowly adapt new measurements with low-pass filter usable_capacity = 0.8 * usable_capacity + 0.2 * discharged_Ah; } // simple SOH estimation soh = usable_capacity / bat_conf->nominal_capacity; } else if (bat_temperature > bat_conf->discharge_temp_max) { port->neg_current_limit = 0; dev_stat.set_error(ERR_BAT_DIS_OVERTEMP); } else if (bat_temperature < bat_conf->discharge_temp_min) { port->neg_current_limit = 0; dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP); } } else { // discharging currently not allowed. should we allow it? if (port->voltage >= num_batteries * (bat_conf->voltage_load_reconnect - port->current * port->neg_droop_res) && bat_temperature < bat_conf->discharge_temp_max - 1 && bat_temperature > bat_conf->discharge_temp_min + 1) { // discharge current is stored as absolute value in bat_conf, but defined // as negative current for power port port->neg_current_limit = -bat_conf->discharge_current_max; // delete all discharge error flags dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP); dev_stat.clear_error(ERR_BAT_DIS_UNDERTEMP); dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE); } } } void Charger::charge_control(BatConf *bat_conf) { // check battery temperature for charging direction if (bat_temperature > bat_conf->charge_temp_max) { port->pos_current_limit = 0; dev_stat.set_error(ERR_BAT_CHG_OVERTEMP); enter_state(CHG_STATE_IDLE); } else if (bat_temperature < bat_conf->charge_temp_min) { port->pos_current_limit = 0; dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP); enter_state(CHG_STATE_IDLE); } if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) && port->voltage < (bat_conf->voltage_absolute_max - 0.5) * num_batteries) { dev_stat.clear_error(ERR_BAT_OVERVOLTAGE); } // state machine switch (state) { case CHG_STATE_IDLE: { if (port->voltage < bat_conf->voltage_recharge * num_batteries && (time(NULL) - time_state_changed) > bat_conf->time_limit_recharge && bat_temperature < bat_conf->charge_temp_max - 1 && bat_temperature > bat_conf->charge_temp_min + 1) { port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); port->pos_current_limit = bat_conf->charge_current_max; full = false; dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP); dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP); dev_stat.clear_error(ERR_BAT_OVERVOLTAGE); enter_state(CHG_STATE_BULK); } break; } case CHG_STATE_BULK: { // continuously adjust voltage setting for temperature compensation port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); if (port->voltage > num_batteries * (port->sink_voltage_max - port->current * port->pos_droop_res)) { enter_state(CHG_STATE_TOPPING); } break; } case CHG_STATE_TOPPING: { // continuously adjust voltage setting for temperature compensation port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); if (port->voltage >= num_batteries * (port->sink_voltage_max - port->current * port->pos_droop_res)) { time_voltage_limit_reached = time(NULL); } // cut-off limit reached because battery full (i.e. CV limit still // reached by available solar power within last 2s) or CV period long enough? if ((port->current < bat_conf->topping_current_cutoff && (time(NULL) - time_voltage_limit_reached) < 2) || (time(NULL) - time_state_changed) > bat_conf->topping_duration) { full = true; num_full_charges++; discharged_Ah = 0; // reset coulomb counter first_full_charge_reached = true; if (bat_conf->equalization_enabled && ( (time(NULL) - time_last_equalization) / (24*60*60) >= bat_conf->equalization_trigger_days || num_deep_discharges - deep_dis_last_equalization >= bat_conf->equalization_trigger_deep_cycles)) { port->sink_voltage_max = bat_conf->equalization_voltage; port->pos_current_limit = bat_conf->equalization_current_limit; enter_state(CHG_STATE_EQUALIZATION); } else if (bat_conf->trickle_enabled) { port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); enter_state(CHG_STATE_TRICKLE); } else { port->pos_current_limit = 0; enter_state(CHG_STATE_IDLE); } } break; } case CHG_STATE_TRICKLE: { // continuously adjust voltage setting for temperature compensation port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); if (port->voltage >= num_batteries * (port->sink_voltage_max - port->current * port->pos_droop_res)) { time_voltage_limit_reached = time(NULL); } if (time(NULL) - time_voltage_limit_reached > bat_conf->trickle_recharge_time) { port->pos_current_limit = bat_conf->charge_current_max; full = false; enter_state(CHG_STATE_BULK); } // assumption: trickle does not harm the battery --> never go back to idle // (for Li-ion battery: disable trickle!) break; } case CHG_STATE_EQUALIZATION: { // continuously adjust voltage setting for temperature compensation port->sink_voltage_max = num_batteries * (bat_conf->equalization_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); // current or time limit for equalization reached if (time(NULL) - time_state_changed > bat_conf->equalization_duration) { // reset triggers time_last_equalization = time(NULL); deep_dis_last_equalization = num_deep_discharges; discharged_Ah = 0; // reset coulomb counter again if (bat_conf->trickle_enabled) { port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); enter_state(CHG_STATE_TRICKLE); } else { port->pos_current_limit = 0; enter_state(CHG_STATE_IDLE); } } break; } } } void battery_init_dc_bus(PowerPort *port, BatConf *bat, unsigned int num_batteries) { unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed port->src_voltage_start = bat->voltage_load_reconnect * n; port->src_voltage_stop = bat->voltage_load_disconnect * n; port->neg_current_limit = -bat->discharge_current_max; // negative sign for compensation of actual resistance port->neg_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n; port->sink_voltage_max = bat->topping_voltage * n; port->sink_voltage_min = bat->voltage_absolute_min * n; port->pos_current_limit = bat->charge_current_max; // negative sign for compensation of actual resistance port->pos_droop_res = -bat->wire_resistance * n; }