- Introduce new CONFIG_HAS_USB_PWR_OUTPUT - Improve charger.discharge_control function - Add battery empty flag
334 lines
10 KiB
C++
334 lines
10 KiB
C++
/*
|
|
* Copyright (c) 2018 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "tests.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
|
|
#include "setup.h"
|
|
|
|
static void init_structs()
|
|
{
|
|
battery_conf_init(&bat_conf, BAT_TYPE_FLOODED, 6, 100);
|
|
charger.init_terminal(&bat_conf);
|
|
charger.state = CHG_STATE_IDLE;
|
|
charger.bat_temperature = 25;
|
|
bat_terminal.bus->voltage = 14.0;
|
|
bat_terminal.current = 0;
|
|
}
|
|
|
|
void no_start_at_high_voltage()
|
|
{
|
|
init_structs();
|
|
bat_terminal.bus->voltage = bat_conf.voltage_recharge + 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void no_start_after_short_rest()
|
|
{
|
|
init_structs();
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge + 1;
|
|
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void no_start_outside_temperature_limits()
|
|
{
|
|
init_structs();
|
|
charger.bat_temperature = bat_conf.charge_temp_max + 1;
|
|
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
|
|
charger.bat_temperature = bat_conf.charge_temp_min - 1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void start_if_everything_just_fine()
|
|
{
|
|
init_structs();
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
|
|
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
|
|
}
|
|
|
|
void enter_topping_at_voltage_setpoint()
|
|
{
|
|
init_structs();
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
|
|
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
|
|
}
|
|
|
|
void topping_to_bulk_after_8h_low_power()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
|
|
charger.time_state_changed = time(NULL) - 8 * 60 * 60 + 1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage - 0.1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff + 0.1;
|
|
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
|
|
|
|
charger.time_state_changed = time(NULL) - 8 * 60 * 60 - 1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
|
|
}
|
|
|
|
void stop_topping_after_time_limit()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
|
|
charger.target_voltage_timer = bat_conf.topping_duration - 1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff + 0.1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage -
|
|
bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1;
|
|
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
|
|
|
|
charger.target_voltage_timer = bat_conf.topping_duration + 1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
|
|
}
|
|
|
|
void stop_topping_at_cutoff_current()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
|
|
charger.target_voltage_timer = 0;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage -
|
|
bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
|
|
}
|
|
|
|
void trickle_to_idle_for_li_ion()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage -
|
|
bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void no_equalization_if_disabled()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
bat_conf.equalization_enabled = false;
|
|
|
|
// set triggers such that it would normally start
|
|
charger.deep_dis_last_equalization =
|
|
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles;
|
|
charger.time_last_equalization =
|
|
time(NULL) - bat_conf.equalization_trigger_days * 24*60*60;
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_NOT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
|
|
}
|
|
|
|
void no_equalization_if_limits_not_reached()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
bat_conf.equalization_enabled = true;
|
|
|
|
// set triggers such that they are just NOT reached
|
|
charger.deep_dis_last_equalization =
|
|
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles + 1;
|
|
charger.time_last_equalization =
|
|
time(NULL) - (bat_conf.equalization_trigger_days - 1) * 24*60*60;
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_NOT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
|
|
}
|
|
|
|
void trickle_to_equalization_if_enabled_and_time_limit_reached()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
bat_conf.equalization_enabled = true;
|
|
charger.time_last_equalization =
|
|
time(NULL) - bat_conf.equalization_trigger_days * 24*60*60;
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage -
|
|
bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
|
|
}
|
|
|
|
|
|
void trickle_to_equalization_if_enabled_and_deep_dis_limit_reached()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
bat_conf.equalization_enabled = true;
|
|
charger.deep_dis_last_equalization =
|
|
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles;
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
|
|
bat_terminal.bus->voltage = bat_conf.topping_voltage -
|
|
bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
|
|
}
|
|
|
|
|
|
void stop_equalization_after_time_limit()
|
|
{
|
|
trickle_to_equalization_if_enabled_and_time_limit_reached();
|
|
|
|
charger.time_state_changed = time(NULL) - bat_conf.equalization_duration + 1;
|
|
bat_terminal.bus->voltage = bat_conf.equalization_voltage -
|
|
bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1;
|
|
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
|
|
|
|
charger.time_state_changed = time(NULL) - bat_conf.topping_duration - 1;
|
|
charger.charge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
|
|
}
|
|
|
|
void restart_bulk_from_trickle_if_voltage_drops()
|
|
{
|
|
TEST_ASSERT(0);
|
|
}
|
|
|
|
void stop_discharge_at_low_voltage()
|
|
{
|
|
init_structs();
|
|
|
|
bat_terminal.bus->voltage = 14;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
|
|
|
|
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min - 0.1;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
|
}
|
|
|
|
void stop_discharge_at_overtemp()
|
|
{
|
|
init_structs();
|
|
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
|
|
|
|
charger.bat_temperature = bat_conf.discharge_temp_max + 1;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
|
}
|
|
|
|
void stop_discharge_at_undertemp()
|
|
{
|
|
init_structs();
|
|
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
|
|
|
|
charger.bat_temperature = bat_conf.discharge_temp_min - 1;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
|
}
|
|
|
|
void restart_discharge_if_allowed()
|
|
{
|
|
init_structs();
|
|
|
|
// stop because of undervoltage
|
|
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min - 0.1;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
|
|
|
// increase voltage slightly above absolute minimum
|
|
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min + 0.05;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
|
|
|
|
// increase voltage above hysteresis voltage
|
|
bat_terminal.bus->voltage = bat_conf.voltage_absolute_min + 0.15;
|
|
charger.discharge_control(&bat_conf);
|
|
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
|
|
}
|
|
|
|
void battery_values_propagated_to_lv_bus_int()
|
|
{
|
|
TEST_ASSERT(0);
|
|
}
|
|
|
|
void no_soc_above_100()
|
|
{
|
|
TEST_ASSERT(0);
|
|
}
|
|
|
|
void no_soc_below_0()
|
|
{
|
|
TEST_ASSERT(0);
|
|
}
|
|
|
|
void bat_charger_tests()
|
|
{
|
|
UNITY_BEGIN();
|
|
|
|
// startup of charging
|
|
RUN_TEST(no_start_at_high_voltage);
|
|
RUN_TEST(no_start_after_short_rest);
|
|
RUN_TEST(no_start_outside_temperature_limits);
|
|
RUN_TEST(start_if_everything_just_fine);
|
|
|
|
// topping
|
|
RUN_TEST(enter_topping_at_voltage_setpoint);
|
|
RUN_TEST(topping_to_bulk_after_8h_low_power);
|
|
RUN_TEST(stop_topping_after_time_limit);
|
|
RUN_TEST(stop_topping_at_cutoff_current);
|
|
|
|
// trickle
|
|
RUN_TEST(trickle_to_idle_for_li_ion);
|
|
|
|
// equalization
|
|
RUN_TEST(no_equalization_if_disabled);
|
|
RUN_TEST(no_equalization_if_limits_not_reached);
|
|
RUN_TEST(trickle_to_equalization_if_enabled_and_time_limit_reached);
|
|
RUN_TEST(trickle_to_equalization_if_enabled_and_deep_dis_limit_reached);
|
|
RUN_TEST(stop_equalization_after_time_limit);
|
|
|
|
//RUN_TEST(restart_bulk_from_trickle_if_voltage_drops);
|
|
|
|
// TODO: temperature compensation
|
|
// TODO: current compensation
|
|
|
|
RUN_TEST(stop_discharge_at_low_voltage);
|
|
RUN_TEST(stop_discharge_at_overtemp);
|
|
RUN_TEST(stop_discharge_at_undertemp);
|
|
RUN_TEST(restart_discharge_if_allowed);
|
|
|
|
//RUN_TEST(battery_values_propagated_to_lv_bus_int);
|
|
|
|
// ToDo: SOC calculation
|
|
//RUN_TEST(no_soc_above_100);
|
|
//RUN_TEST(no_soc_below_0);
|
|
|
|
UNITY_END();
|
|
}
|