/* * Copyright (c) 2018 Martin Jäger / Libre Solar * * SPDX-License-Identifier: Apache-2.0 */ #include "tests.h" #include #include #include "setup.h" static void init_structs() { battery_conf_init(&bat_conf, BAT_TYPE_FLOODED, 6, 100); charger.init_terminal(&bat_conf); charger.state = CHG_STATE_IDLE; charger.bat_temperature = 25; bat_terminal.bus->voltage = 14.0; bat_terminal.current = 0; } void no_start_at_high_voltage() { init_structs(); bat_terminal.bus->voltage = bat_conf.voltage_recharge + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state); } void no_start_after_short_rest() { init_structs(); charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge + 1; bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state); } void no_start_outside_temperature_limits() { init_structs(); charger.bat_temperature = bat_conf.charge_temp_max + 1; bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state); charger.bat_temperature = bat_conf.charge_temp_min - 1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state); } void start_if_everything_just_fine() { init_structs(); charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1; bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state); } void enter_topping_at_voltage_setpoint() { init_structs(); charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1; bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state); bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state); } void topping_to_bulk_after_8h_low_power() { enter_topping_at_voltage_setpoint(); charger.time_state_changed = time(NULL) - 8 * 60 * 60 + 1; bat_terminal.bus->voltage = bat_conf.topping_voltage - 0.1; bat_terminal.current = bat_conf.topping_current_cutoff + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state); charger.time_state_changed = time(NULL) - 8 * 60 * 60 - 1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state); } void stop_topping_after_time_limit() { enter_topping_at_voltage_setpoint(); charger.target_voltage_timer = bat_conf.topping_duration - 1; bat_terminal.current = bat_conf.topping_current_cutoff + 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state); charger.target_voltage_timer = bat_conf.topping_duration + 1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state); } void stop_topping_at_cutoff_current() { enter_topping_at_voltage_setpoint(); charger.target_voltage_timer = 0; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state); } void trickle_to_idle_for_li_ion() { enter_topping_at_voltage_setpoint(); battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100); charger.time_state_changed = time(NULL) - 1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state); } void no_equalization_if_disabled() { enter_topping_at_voltage_setpoint(); bat_conf.equalization_enabled = false; // set triggers such that it would normally start charger.deep_dis_last_equalization = charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles; charger.time_last_equalization = time(NULL) - bat_conf.equalization_trigger_days * 24*60*60; charger.time_state_changed = time(NULL) - 1; bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_NOT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); } void no_equalization_if_limits_not_reached() { enter_topping_at_voltage_setpoint(); bat_conf.equalization_enabled = true; // set triggers such that they are just NOT reached charger.deep_dis_last_equalization = charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles + 1; charger.time_last_equalization = time(NULL) - (bat_conf.equalization_trigger_days - 1) * 24*60*60; charger.time_state_changed = time(NULL) - 1; bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_NOT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); } void trickle_to_equalization_if_enabled_and_time_limit_reached() { enter_topping_at_voltage_setpoint(); bat_conf.equalization_enabled = true; charger.time_last_equalization = time(NULL) - bat_conf.equalization_trigger_days * 24*60*60; charger.time_state_changed = time(NULL) - 1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); } void trickle_to_equalization_if_enabled_and_deep_dis_limit_reached() { enter_topping_at_voltage_setpoint(); bat_conf.equalization_enabled = true; charger.deep_dis_last_equalization = charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles; charger.time_state_changed = time(NULL) - 1; bat_terminal.current = bat_conf.topping_current_cutoff - 0.1; bat_terminal.bus->voltage = bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); } void stop_equalization_after_time_limit() { trickle_to_equalization_if_enabled_and_time_limit_reached(); charger.time_state_changed = time(NULL) - bat_conf.equalization_duration + 1; bat_terminal.bus->voltage = bat_conf.equalization_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state); charger.time_state_changed = time(NULL) - bat_conf.topping_duration - 1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state); } void restart_bulk_from_trickle_if_voltage_drops() { TEST_ASSERT(0); } void stop_discharge_at_low_voltage() { init_structs(); bat_terminal.bus->voltage = 14; charger.discharge_control(&bat_conf); TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); bat_terminal.bus->voltage = bat_conf.voltage_absolute_min - 0.1; charger.discharge_control(&bat_conf); TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); } void stop_discharge_at_overtemp() { init_structs(); TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); charger.bat_temperature = bat_conf.discharge_temp_max + 1; charger.discharge_control(&bat_conf); TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); } void stop_discharge_at_undertemp() { init_structs(); TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); charger.bat_temperature = bat_conf.discharge_temp_min - 1; charger.discharge_control(&bat_conf); TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); } void restart_discharge_if_allowed() { init_structs(); // stop because of undervoltage bat_terminal.bus->voltage = bat_conf.voltage_absolute_min - 0.1; charger.discharge_control(&bat_conf); TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); // increase voltage slightly above absolute minimum bat_terminal.bus->voltage = bat_conf.voltage_absolute_min + 0.05; charger.discharge_control(&bat_conf); TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); // increase voltage above hysteresis voltage bat_terminal.bus->voltage = bat_conf.voltage_absolute_min + 0.15; charger.discharge_control(&bat_conf); TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); } void battery_values_propagated_to_lv_bus_int() { TEST_ASSERT(0); } void no_soc_above_100() { TEST_ASSERT(0); } void no_soc_below_0() { TEST_ASSERT(0); } void bat_charger_tests() { UNITY_BEGIN(); // startup of charging RUN_TEST(no_start_at_high_voltage); RUN_TEST(no_start_after_short_rest); RUN_TEST(no_start_outside_temperature_limits); RUN_TEST(start_if_everything_just_fine); // topping RUN_TEST(enter_topping_at_voltage_setpoint); RUN_TEST(topping_to_bulk_after_8h_low_power); RUN_TEST(stop_topping_after_time_limit); RUN_TEST(stop_topping_at_cutoff_current); // trickle RUN_TEST(trickle_to_idle_for_li_ion); // equalization RUN_TEST(no_equalization_if_disabled); RUN_TEST(no_equalization_if_limits_not_reached); RUN_TEST(trickle_to_equalization_if_enabled_and_time_limit_reached); RUN_TEST(trickle_to_equalization_if_enabled_and_deep_dis_limit_reached); RUN_TEST(stop_equalization_after_time_limit); //RUN_TEST(restart_bulk_from_trickle_if_voltage_drops); // TODO: temperature compensation // TODO: current compensation RUN_TEST(stop_discharge_at_low_voltage); RUN_TEST(stop_discharge_at_overtemp); RUN_TEST(stop_discharge_at_undertemp); RUN_TEST(restart_discharge_if_allowed); //RUN_TEST(battery_values_propagated_to_lv_bus_int); // ToDo: SOC calculation //RUN_TEST(no_soc_above_100); //RUN_TEST(no_soc_below_0); UNITY_END(); }