The fuse destruction set a duty cycle of 0 and started the half bridge. For the STM32 TIM drivers, this did not switch on the low-side MOSFET, as starting is refused with a compare value of 0. Use the new function half_bridge_force_low_side() instead. In addition, the control loop running at 10 Hz could override the forced state, because it saw an enabled half bridge and continued with MPPT control. Now the control function returns early as soon as the HS MOSFET short error is set. The low-side switch is forced on again with each call in case the half bridge was stopped in the meantime, e.g. by an ADC alert. The data is only stored once to avoid unnecessary flash writes if the fuse does not blow. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Libre Solar Charge Controller Firmware
This repository contains the firmware for the different Libre Solar Charge Controllers based on Zephyr RTOS.
Coding style is described here.
Development and release model
The main branch is used for ongoing development of the firmware.
Releases are created from main after significant updates have been introduced to the firmware. Each release has to pass tests with multiple boards.
A release is tagged with a version number consisting of the release year and a release count for that year (starting at zero). For back-porting of bug-fixes, a branch named after the release followed by -branch is created, e.g. v21.0-branch.
Documentation
The firmware documentation including build instructions and API reference can be found under libre.solar/charge-controller-firmware.
In order to build the documentation locally you need to install Doxygen, Sphinx and Breathe and run make html in the docs folder.
License
This firmware is released under the Apache-2.0 License.