The sink and source voltage boundaries for droop control and battery charge voltage management are now part of the DcBus class. Also added source and sink current margins, which will be used by the DC/DC for control targets instead of port current limits, which were difficult to synchronize before.
130 lines
4.7 KiB
C++
130 lines
4.7 KiB
C++
/*
|
|
* Copyright (c) 2016 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#ifndef DCDC_H
|
|
#define DCDC_H
|
|
|
|
/** @file
|
|
*
|
|
* @brief DC/DC buck/boost control functions
|
|
*/
|
|
|
|
#include <stdint.h>
|
|
#include <stdbool.h>
|
|
|
|
#include "power_port.h"
|
|
|
|
/** DC/DC basic operation mode
|
|
*
|
|
* Defines which type of device is connected to the high side and low side ports
|
|
*/
|
|
enum DcdcOperationMode
|
|
{
|
|
MODE_MPPT_BUCK, ///< solar panel at high side port, battery / load at low side port (typical MPPT)
|
|
MODE_MPPT_BOOST, ///< battery at high side port, solar panel at low side (e.g. e-bike charging)
|
|
MODE_NANOGRID ///< accept input power (if available and need for charging) or provide output power
|
|
///< (if no other power source on the grid and battery charged) on the high side port
|
|
///< and dis/charge battery on the low side port, battery voltage must be lower than
|
|
///< nano grid voltage.
|
|
};
|
|
|
|
/** DC/DC control state
|
|
*
|
|
* Allows to determine the current control state (off, CC, CV and MPPT)
|
|
*/
|
|
enum DcdcControlState
|
|
{
|
|
DCDC_STATE_OFF, ///< DC/DC switched off (low input power available or actively disabled)
|
|
DCDC_STATE_MPPT, ///< Maximum Power Point Tracking
|
|
DCDC_STATE_CC, ///< Constant-Current control
|
|
DCDC_STATE_CV, ///< Constant-Voltage control
|
|
DCDC_STATE_DERATING ///< Hardware-limits (current or temperature) reached
|
|
};
|
|
|
|
/** DC/DC class
|
|
*
|
|
* Contains all data belonging to the DC/DC sub-component of the PCB, incl.
|
|
* actual measurements and calibration parameters.
|
|
*/
|
|
class Dcdc
|
|
{
|
|
public:
|
|
/** Initialize DC/DC and DC/DC port structs
|
|
*
|
|
* See http://libre.solar/docs/dcdc_control for detailed information
|
|
*
|
|
* @param hv_side High voltage terminal (e.g. solar input for MPPT buck)
|
|
* @param lv_side Low voltage terminal (e.g. battery output for MPPT buck)
|
|
* @param mode Operation mode (buck, boost or nanogrid)
|
|
*/
|
|
Dcdc(PowerPort *hv_side, PowerPort* lv_side, DcdcOperationMode mode);
|
|
|
|
/** Check for valid start conditions of the DC/DC converter
|
|
*
|
|
* @returns 1 for buck mode, -1 for boost mode and 0 for invalid conditions
|
|
*/
|
|
int check_start_conditions();
|
|
|
|
/** Main control function for the DC/DC converter
|
|
*
|
|
* If DC/DC is off, this function checks start conditions and starts conversion if possible.
|
|
*/
|
|
void control();
|
|
|
|
/** Test mode for DC/DC, ramping up to 50% duty cycle
|
|
*/
|
|
void test();
|
|
|
|
/** Fast emergency stop function
|
|
*
|
|
* May be called from an ISR which detected overvoltage / overcurrent conditions
|
|
*/
|
|
void emergency_stop();
|
|
|
|
/** Prevent overcharging of battery in case of shorted HS MOSFET
|
|
*
|
|
* This function switches the LS MOSFET continuously on to blow the battery input fuse. The
|
|
* reason for self destruction should be logged and stored to EEPROM prior to calling this
|
|
* function, as the charge controller power supply will be cut after the fuse is destroyed.
|
|
*/
|
|
void fuse_destruction();
|
|
|
|
DcdcOperationMode mode; ///< DC/DC mode (buck, boost or nanogrid)
|
|
bool enable; ///< Can be used to disable the DC/DC power stage
|
|
uint16_t state; ///< Control state (off / MPPT / CC / CV)
|
|
|
|
// actual measurements
|
|
PowerPort *hvs; ///< Pointer to DC bus at high voltage side
|
|
PowerPort *lvs; ///< Pointer to DC bus at low voltage (inductor) side
|
|
float temp_mosfets; ///< MOSFET temperature measurement (if existing)
|
|
|
|
// current state
|
|
float power_prev; ///< Stores previous conversion power (set via dcdc_control)
|
|
int32_t pwm_delta; ///< Direction of PWM change for MPPT
|
|
int32_t off_timestamp; ///< Last time the DC/DC was switched off
|
|
int32_t power_good_timestamp; ///< Last time the DC/DC reached above minimum output power
|
|
|
|
// maximum allowed values
|
|
float ls_current_max; ///< Maximum low-side (inductor) current
|
|
float hs_voltage_max; ///< Maximum high-side voltage
|
|
float ls_voltage_max; ///< Maximum low-side voltage
|
|
float ls_voltage_min; ///< Minimum low-side voltage, e.g. for driver supply
|
|
float output_power_min; ///< Minimum output power (if lower, DC/DC is switched off)
|
|
|
|
// calibration parameters
|
|
uint32_t restart_interval; ///< Restart interval (s): When should we retry to start
|
|
///< charging after low output power cut-off?
|
|
|
|
private:
|
|
/** Calculates the duty cycle change depending on operating mode and actual measurements
|
|
*
|
|
* @returns duty cycle step (-1 or 1) or 0 if DC/DC should be switched off
|
|
*/
|
|
int duty_cycle_delta();
|
|
};
|
|
|
|
#endif /* DCDC_H */
|