/* * Copyright (c) 2016 Martin Jäger / Libre Solar * * SPDX-License-Identifier: Apache-2.0 */ #ifndef DCDC_H #define DCDC_H /** @file * * @brief DC/DC buck/boost control functions */ #include #include #include "power_port.h" /** DC/DC basic operation mode * * Defines which type of device is connected to the high side and low side ports */ enum DcdcOperationMode { MODE_MPPT_BUCK, ///< solar panel at high side port, battery / load at low side port (typical MPPT) MODE_MPPT_BOOST, ///< battery at high side port, solar panel at low side (e.g. e-bike charging) MODE_NANOGRID ///< accept input power (if available and need for charging) or provide output power ///< (if no other power source on the grid and battery charged) on the high side port ///< and dis/charge battery on the low side port, battery voltage must be lower than ///< nano grid voltage. }; /** DC/DC control state * * Allows to determine the current control state (off, CC, CV and MPPT) */ enum DcdcControlState { DCDC_STATE_OFF, ///< DC/DC switched off (low input power available or actively disabled) DCDC_STATE_MPPT, ///< Maximum Power Point Tracking DCDC_STATE_CC, ///< Constant-Current control DCDC_STATE_CV, ///< Constant-Voltage control DCDC_STATE_DERATING ///< Hardware-limits (current or temperature) reached }; /** DC/DC class * * Contains all data belonging to the DC/DC sub-component of the PCB, incl. * actual measurements and calibration parameters. */ class Dcdc { public: /** Initialize DC/DC and DC/DC port structs * * See http://libre.solar/docs/dcdc_control for detailed information * * @param hv_side High voltage terminal (e.g. solar input for MPPT buck) * @param lv_side Low voltage terminal (e.g. battery output for MPPT buck) * @param mode Operation mode (buck, boost or nanogrid) */ Dcdc(PowerPort *hv_side, PowerPort* lv_side, DcdcOperationMode mode); /** Check for valid start conditions of the DC/DC converter * * @returns 1 for buck mode, -1 for boost mode and 0 for invalid conditions */ int check_start_conditions(); /** Main control function for the DC/DC converter * * If DC/DC is off, this function checks start conditions and starts conversion if possible. */ void control(); /** Test mode for DC/DC, ramping up to 50% duty cycle */ void test(); /** Fast emergency stop function * * May be called from an ISR which detected overvoltage / overcurrent conditions */ void emergency_stop(); /** Prevent overcharging of battery in case of shorted HS MOSFET * * This function switches the LS MOSFET continuously on to blow the battery input fuse. The * reason for self destruction should be logged and stored to EEPROM prior to calling this * function, as the charge controller power supply will be cut after the fuse is destroyed. */ void fuse_destruction(); DcdcOperationMode mode; ///< DC/DC mode (buck, boost or nanogrid) bool enable; ///< Can be used to disable the DC/DC power stage uint16_t state; ///< Control state (off / MPPT / CC / CV) // actual measurements PowerPort *hvs; ///< Pointer to DC bus at high voltage side PowerPort *lvs; ///< Pointer to DC bus at low voltage (inductor) side float temp_mosfets; ///< MOSFET temperature measurement (if existing) // current state float power_prev; ///< Stores previous conversion power (set via dcdc_control) int32_t pwm_delta; ///< Direction of PWM change for MPPT int32_t off_timestamp; ///< Last time the DC/DC was switched off int32_t power_good_timestamp; ///< Last time the DC/DC reached above minimum output power // maximum allowed values float ls_current_max; ///< Maximum low-side (inductor) current float hs_voltage_max; ///< Maximum high-side voltage float ls_voltage_max; ///< Maximum low-side voltage float ls_voltage_min; ///< Minimum low-side voltage, e.g. for driver supply float output_power_min; ///< Minimum output power (if lower, DC/DC is switched off) // calibration parameters uint32_t restart_interval; ///< Restart interval (s): When should we retry to start ///< charging after low output power cut-off? private: /** Calculates the duty cycle change depending on operating mode and actual measurements * * @returns duty cycle step (-1 or 1) or 0 if DC/DC should be switched off */ int duty_cycle_delta(); }; #endif /* DCDC_H */