Martin JägerandClaude Opus 5.5 427943994c drivers: half_bridge: add function to force low-side switch on
Add half_bridge_force_low_side() to switch the low-side switch
continuously on, bypassing the compare value limits. This is required
for safety measures like blowing the battery fuse in case of a shorted
high-side MOSFET.

Previously, this was attempted by setting a duty cycle of 0 and
starting the PWM. However, the STM32 timer drivers refuse to start with
a compare value of 0, so the low-side switch was never turned on.

The forced state is kept until half_bridge_stop() is called. Changes of
the compare value or its limits and start requests are rejected with
-EBUSY meanwhile, so that a concurrently running control loop can't
override it.

- advtim: Compare value 0 keeps OCxREF low, so that CHxN stays on. The
  output mode can't be changed, as it is locked during initialization.
- gptim: Compare value 0 for both channels, so that the low-side
  channel with inverted polarity stays on.
- HRTIM: Output 1 is reset by software and set events are removed, so
  that the complementary output 2 stays on.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 08:43:53 +02:00
2023-08-16 13:34:30 +02:00
2016-08-02 14:02:09 +02:00
2019-11-11 21:02:26 +01:00
2026-10-20 20:34:01 +02:00
2017-04-14 18:04:13 +02:00
2021-12-16 15:58:18 +01:00
2026-04-16 08:41:31 +02:00

Libre Solar Charge Controller Firmware

build badge

This repository contains the firmware for the different Libre Solar Charge Controllers based on Zephyr RTOS.

Coding style is described here.

Development and release model

The main branch is used for ongoing development of the firmware.

Releases are created from main after significant updates have been introduced to the firmware. Each release has to pass tests with multiple boards.

A release is tagged with a version number consisting of the release year and a release count for that year (starting at zero). For back-porting of bug-fixes, a branch named after the release followed by -branch is created, e.g. v21.0-branch.

Documentation

The firmware documentation including build instructions and API reference can be found under libre.solar/charge-controller-firmware.

In order to build the documentation locally you need to install Doxygen, Sphinx and Breathe and run make html in the docs folder.

License

This firmware is released under the Apache-2.0 License.

S
Description
Firmware for Libre Solar MPPT/PWM charge controllers
https://libre.solar/charge-controller-firmware/
Readme
5.7 MiB
Languages
C++ 77.6%
C 18.1%
CMake 1.6%
Python 1.4%
Shell 0.7%
Other 0.6%