Martin JägerandClaude Opus 5.5 bfbe98a62e app: enable HS MOSFET fail-safe protection based on devicetree
The fuse destruction in case of a shorted high-side MOSFET was enabled
for all boards with DC/DC converter, even if the board doesn't have a
fuse at the low-side terminal (e.g. Nucleo G474RE).

Add an ls-fuse property to the charge-controller binding to describe
this hardware feature and make HS_MOSFET_FAIL_SAFE_PROTECTION depend on
it. The property is added to all MPPT boards, so the behavior does not
change for them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:18:46 +02:00

71 lines
2.4 KiB
YAML

# Copyright (c) The Libre Solar Project Contributors
# SPDX-License-Identifier: Apache-2.0
description: Generic charge controller device setup
compatible: "charge-controller"
properties:
type:
type: string
required: true
description: Device type
version-str:
type: string
required: true
description: Hardware version number (human-readable)
version-num:
type: int
required: true
description: Hardware version number (usable in preprocessor defines)
hs-voltage-max:
type: int
required: true
description: Maximum voltage at high-side (typically PV input) in volts
ls-voltage-max:
type: int
required: true
description: Maximum voltage at low-side (typically battery) in volts
dcdc-current-max:
type: int
description: Maximum inductor current in amps (if existing in the charge controller)
ls-fuse:
type: boolean
description: |
Low-side (typically battery) terminal is protected by a fuse
The fuse can be blown by switching on the low-side MOSFET of the DC/DC converter
continuously, which shorts the low-side terminal through the inductor. This is used to
prevent overcharging of the battery in case of a shorted high-side MOSFET.
internal-tref-max:
type: int
default: 50
description: |
Internal reference temperature at full load (°C)
This value is used for model-based control of overcurrent protection. It represents
the steady-state internal temperature for max. continuous current at ambient
temperature of 25°C. Default value is conservative and can be overwritten in PCB
configuration.
mosfets-tj-max:
type: int
default: 120
description: |
Maximum Tj of MOSFETs (°C)
This value is used for model-based control of overcurrent protection. It represents
the steady-state junction temperature for max. continuous current at ambient
temperature of 25°C.
mosfets-tau-ja:
type: int
default: 5
description: |
Thermal time constant junction to ambient (s)
This value is used for model-based control of overcurrent protection. It does not reflect
the much lower MOSFET-internal time constant junction to case, but includes thermal
inertia of the board.
Around 5s seems to be a good conservative estimation for 5x6 type SMD MOSFETs. Take larger
values for big heat sinks.