app: enable HS MOSFET fail-safe protection based on devicetree
The fuse destruction in case of a shorted high-side MOSFET was enabled for all boards with DC/DC converter, even if the board doesn't have a fuse at the low-side terminal (e.g. Nucleo G474RE). Add an ls-fuse property to the charge-controller binding to describe this hardware feature and make HS_MOSFET_FAIL_SAFE_PROTECTION depend on it. The property is added to all MPPT boards, so the behavior does not change for them. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
b1cd0b6922
commit
bfbe98a62e
+5
-1
@@ -19,11 +19,15 @@ config CONTROL_FREQUENCY
|
||||
config HS_MOSFET_FAIL_SAFE_PROTECTION
|
||||
bool
|
||||
default y
|
||||
depends on $(dt_node_bool_prop,/pcb,ls-fuse)
|
||||
help
|
||||
If enabled, the DC/DC control function will will detect if the high-side MOSFET has failed
|
||||
If enabled, the DC/DC control function will detect if the high-side MOSFET has failed
|
||||
short and trip the fuse by switching the low-side MOSFET continuously on. This will prevent
|
||||
accidental overcharging of the battery.
|
||||
|
||||
Only available if the board has a fuse at the low-side terminal (ls-fuse property of the
|
||||
pcb devicetree node).
|
||||
|
||||
#
|
||||
# Visible (user-configurable) Kconfig symbols
|
||||
#
|
||||
|
||||
@@ -20,6 +20,7 @@
|
||||
hs-voltage-max = <40>;
|
||||
ls-voltage-max = <16>;
|
||||
dcdc-current-max = <10>;
|
||||
ls-fuse;
|
||||
};
|
||||
|
||||
chosen {
|
||||
|
||||
@@ -20,6 +20,7 @@
|
||||
hs-voltage-max = <90>;
|
||||
ls-voltage-max = <32>;
|
||||
dcdc-current-max = <20>;
|
||||
ls-fuse;
|
||||
};
|
||||
|
||||
chosen {
|
||||
|
||||
@@ -22,6 +22,7 @@
|
||||
hs-voltage-max = <80>;
|
||||
ls-voltage-max = <32>;
|
||||
dcdc-current-max = <20>;
|
||||
ls-fuse;
|
||||
};
|
||||
|
||||
chosen {
|
||||
|
||||
@@ -22,6 +22,7 @@
|
||||
hs-voltage-max = <55>;
|
||||
ls-voltage-max = <32>;
|
||||
dcdc-current-max = <20>;
|
||||
ls-fuse;
|
||||
};
|
||||
|
||||
chosen {
|
||||
|
||||
@@ -22,6 +22,7 @@
|
||||
hs-voltage-max = <80>;
|
||||
ls-voltage-max = <32>;
|
||||
dcdc-current-max = <20>;
|
||||
ls-fuse;
|
||||
};
|
||||
|
||||
chosen {
|
||||
|
||||
@@ -29,6 +29,14 @@ properties:
|
||||
dcdc-current-max:
|
||||
type: int
|
||||
description: Maximum inductor current in amps (if existing in the charge controller)
|
||||
ls-fuse:
|
||||
type: boolean
|
||||
description: |
|
||||
Low-side (typically battery) terminal is protected by a fuse
|
||||
|
||||
The fuse can be blown by switching on the low-side MOSFET of the DC/DC converter
|
||||
continuously, which shorts the low-side terminal through the inductor. This is used to
|
||||
prevent overcharging of the battery in case of a shorted high-side MOSFET.
|
||||
internal-tref-max:
|
||||
type: int
|
||||
default: 50
|
||||
|
||||
Reference in New Issue