50 lines
1.4 KiB
C++
50 lines
1.4 KiB
C++
/*
|
|
* Copyright (c) 2017 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "power_port.h"
|
|
|
|
void PowerPort::init_solar()
|
|
{
|
|
neg_current_limit = -50; // derating based on max. DC/DC or PWM switch current only
|
|
pos_current_limit = 0; // no current towards solar panel allowed
|
|
}
|
|
|
|
void PowerPort::init_nanogrid()
|
|
{
|
|
pos_current_limit = 5.0;
|
|
neg_current_limit = -5.0;
|
|
|
|
// 1 Ohm means 1V change of target voltage per amp, same droop for both current directions.
|
|
bus->sink_droop_res = 0.1;
|
|
bus->src_droop_res = 0.1;
|
|
|
|
// also initialize the connected bus
|
|
bus->src_voltage_bound = 30.0; // starting buck mode above this point
|
|
bus->sink_voltage_bound = 28.0; // boost mode until this voltage is reached
|
|
}
|
|
|
|
void PowerPort::energy_balance()
|
|
{
|
|
// remark: timespan = 1s, so no multiplication with time necessary for energy calculation
|
|
if (current >= 0.0F) {
|
|
pos_energy_Wh += bus->voltage * current / 3600.0;
|
|
}
|
|
else {
|
|
neg_energy_Wh -= bus->voltage * current / 3600.0;
|
|
}
|
|
}
|
|
|
|
void PowerPort::update_bus_current_margins()
|
|
{
|
|
// charging direction of battery
|
|
bus->sink_current_margin = pos_current_limit - current;
|
|
|
|
// discharging direction of battery
|
|
bus->src_current_margin = neg_current_limit - current;
|
|
|
|
//printf("pos: %.3f neg: %.3f current: %.3f\n", pos_current_limit, neg_current_limit, current);
|
|
}
|