Commit Graph
17 Commits
Author SHA1 Message Date
Martin Jäger 0c20545f88 Differentiate between src and sink droop res again
Necessary for improved load disconnect switch behavior.
2020-02-19 14:34:40 +01:00
Martin Jaeger 43f90eea7c Move voltage control parameters to DcBus class
The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
2020-02-07 12:03:25 +01:00
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger 93418fc8c8 Fixed basic nanogrid port implementation
Instead of SOLAR_TERMINAL, GRID_TERMINAL has to be defined in config.h
(see also template).
2019-12-20 14:52:57 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger ad27142cd8 Fix DC/DC and PWM switch current limit control (#79) 2019-11-11 19:33:30 +01:00
Martin Jaeger ba10a2882c Fixing load output and improved overvoltage config
Previous load output expected the battery port as a parameter and checked if
discharging of the battery was allowed. New implementation has own load port
and needs to check if current output (i.e. positive direction) is allowed.

Overvoltage setting is now configured via power port sink_voltage_max.
2019-10-23 13:16:04 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger 515b098e85 Passing of bat voltage and current limits to other ports updated 2019-10-23 07:29:05 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger 7c75548193 DC bus type introduced and unit tests added 2019-05-07 18:56:04 +02:00
Martin Jaeger 213ebf8c17 Improved load overcurrent and overvoltage diagnosis and protection 2019-04-28 17:29:57 +02:00
Martin Jaeger e05fd95e17 Current compensation for load switch thresholds added 2019-04-18 09:23:58 +02:00
Martin Jaeger e4a20fba85 Battery config updated and started with Doxygen added 2019-03-10 18:34:05 +01:00
Martin Jaeger 4e0b7f2a12 Restructuring of data types (structs) and files
- dcdc_port_t renamed to power_port_t for future use in PWM charge controllers
- structs.h split into battery.h, log.h and charger.h
- bat_charger.cpp/h split into battery.cpp/h and charger.cpp/h
2019-03-10 17:19:44 +01:00