The sink and source voltage boundaries for droop control and battery
charge voltage management are now part of the DcBus class.
Also added source and sink current margins, which will be used by the
DC/DC for control targets instead of port current limits, which were
difficult to synchronize before.
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
Previous load output expected the battery port as a parameter and checked if
discharging of the battery was allowed. New implementation has own load port
and needs to check if current output (i.e. positive direction) is allowed.
Overvoltage setting is now configured via power port sink_voltage_max.
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.
With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
- dcdc_port_t renamed to power_port_t for future use in PWM charge controllers
- structs.h split into battery.h, log.h and charger.h
- bat_charger.cpp/h split into battery.cpp/h and charger.cpp/h