The DC bus type caused issues because current limits could not be defined individually for each connection to a junction, as described in issue #50. With this commit, also some structs were converted to C++ classes to improve readibility of the code and make sure that pointers (e.g. to PowerPort objects) are always assigned during initialization.
139 lines
4.2 KiB
C++
139 lines
4.2 KiB
C++
|
|
#include "tests.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
#include <math.h>
|
|
|
|
#include "main.h"
|
|
|
|
extern PowerPort *solar_terminal;
|
|
extern PowerPort *bat_terminal;
|
|
|
|
void reset_counters_at_start_of_day()
|
|
{
|
|
solar_terminal->bus->voltage = bat_terminal->bus->voltage - 1;
|
|
|
|
log_data.day_counter = 0;
|
|
|
|
solar_terminal->dis_energy_Wh = 10.0;
|
|
bat_terminal->dis_energy_Wh = 3.0;
|
|
bat_terminal->chg_energy_Wh = 4.0;
|
|
load_terminal.chg_energy_Wh = 9.0;
|
|
|
|
// 5 houurs without sun
|
|
for (int i = 0; i <= 5 * 60 * 60; i++) {
|
|
log_update_energy(&log_data, solar_terminal, bat_terminal, &load_terminal);
|
|
}
|
|
|
|
TEST_ASSERT_EQUAL(10, log_data.solar_in_total_Wh);
|
|
TEST_ASSERT_EQUAL(3, log_data.bat_dis_total_Wh);
|
|
TEST_ASSERT_EQUAL(4, log_data.bat_chg_total_Wh);
|
|
TEST_ASSERT_EQUAL(9, log_data.load_out_total_Wh);
|
|
|
|
TEST_ASSERT_EQUAL(10, solar_terminal->dis_energy_Wh);
|
|
TEST_ASSERT_EQUAL(3, bat_terminal->dis_energy_Wh);
|
|
TEST_ASSERT_EQUAL(4, bat_terminal->chg_energy_Wh);
|
|
TEST_ASSERT_EQUAL(9, load_terminal.chg_energy_Wh);
|
|
|
|
// solar didn't come back yet
|
|
TEST_ASSERT_EQUAL(0, log_data.day_counter);
|
|
|
|
// now solar power comes back
|
|
solar_terminal->bus->voltage = bat_terminal->bus->voltage + 1;
|
|
log_update_energy(&log_data, solar_terminal, bat_terminal, &load_terminal);
|
|
|
|
// day counter should be increased and daily energy counters reset
|
|
TEST_ASSERT_EQUAL(1, log_data.day_counter);
|
|
TEST_ASSERT_EQUAL(0, solar_terminal->dis_energy_Wh);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal->dis_energy_Wh);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal->chg_energy_Wh);
|
|
TEST_ASSERT_EQUAL(0, load_terminal.chg_energy_Wh);
|
|
}
|
|
|
|
void log_new_solar_voltage_max()
|
|
{
|
|
solar_terminal->bus->voltage = 40;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(40, log_data.solar_voltage_max);
|
|
}
|
|
|
|
void log_new_bat_voltage_max()
|
|
{
|
|
bat_terminal->bus->voltage = 31;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(31, log_data.battery_voltage_max);
|
|
}
|
|
|
|
void log_new_dcdc_current_max()
|
|
{
|
|
dcdc.lvs->current = 21;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(21, log_data.dcdc_current_max);
|
|
}
|
|
|
|
void log_new_load_current_max()
|
|
{
|
|
load.port->current = 21;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(21, log_data.load_current_max);
|
|
}
|
|
|
|
void log_solar_power_max()
|
|
{
|
|
solar_terminal->power = -50;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(50, log_data.solar_power_max_day);
|
|
TEST_ASSERT_EQUAL(50, log_data.solar_power_max_total);
|
|
}
|
|
|
|
void log_load_power_max()
|
|
{
|
|
load.port->power = 50;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(50, log_data.load_power_max_day);
|
|
TEST_ASSERT_EQUAL(50, log_data.load_power_max_total);
|
|
}
|
|
|
|
void log_new_mosfet_temp_max()
|
|
{
|
|
dcdc.temp_mosfets = 80;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(80, log_data.mosfet_temp_max);
|
|
}
|
|
|
|
void log_new_bat_temp_max()
|
|
{
|
|
charger.bat_temperature = 45;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(45, log_data.bat_temp_max);
|
|
}
|
|
|
|
extern float mcu_temp;
|
|
|
|
void log_new_int_temp_max()
|
|
{
|
|
mcu_temp = 22;
|
|
log_update_min_max_values(&log_data, &dcdc, &charger, &load, solar_terminal, bat_terminal, &load_terminal);
|
|
TEST_ASSERT_EQUAL(22, log_data.int_temp_max);
|
|
}
|
|
|
|
void log_tests()
|
|
{
|
|
UNITY_BEGIN();
|
|
|
|
RUN_TEST(reset_counters_at_start_of_day);
|
|
|
|
RUN_TEST(log_new_solar_voltage_max);
|
|
RUN_TEST(log_new_bat_voltage_max);
|
|
RUN_TEST(log_new_dcdc_current_max);
|
|
RUN_TEST(log_new_load_current_max);
|
|
RUN_TEST(log_solar_power_max);
|
|
RUN_TEST(log_load_power_max);
|
|
RUN_TEST(log_new_mosfet_temp_max);
|
|
RUN_TEST(log_new_bat_temp_max);
|
|
RUN_TEST(log_new_int_temp_max);
|
|
|
|
UNITY_END();
|
|
}
|