# Copyright (c) The Libre Solar Project Contributors
# SPDX-License-Identifier: Apache-2.0
mainmenu "Libre Solar Charge Controller Firmware"
#
# Invisible (board-specific) Kconfig symbols
#
config CONTROL_FREQUENCY
int
default 10
help
Main control function frequency (Hz)
Frequencies higher than 10 Hz caused issues with MPPT control during lab test with
PV simulator. Might be different with actual solar panel.
config LIBRE_SOLAR_TYPE_ID
int
help
Numeric Libre Solar hardware type ID
config HS_MOSFET_FAIL_SAFE_PROTECTION
bool
default y
help
If enabled, the DC/DC control function will will detect if the high-side MOSFET has failed
short and trip the fuse by switching the low-side MOSFET continuously on. This will prevent
accidental overcharging of the battery.
#
# Visible (user-configurable) Kconfig symbols
#
menu "Charge Controller Setup"
choice
prompt "High-voltage terminal"
depends on $(dt_compat_enabled,half-bridge)
help
Select the device connected to the high-voltage
side terminal of the DC/DC converter.
config HV_TERMINAL_SOLAR
bool "Solar panel"
config HV_TERMINAL_NANOGRID
bool "DC nanogrid"
config HV_TERMINAL_GENERATOR
bool "DC generator, e.g. wind turbine"
config HV_TERMINAL_BATTERY
bool "Battery, e.g. electric bicycle"
endchoice
choice
prompt "Low-voltage terminal"
help
Select the device connected to the low-voltage side
of the charge controller (usually battery terminal).
config LV_TERMINAL_BATTERY
depends on !HV_TERMINAL_BATTERY
bool "Battery 12V/24V"
config LV_TERMINAL_SOLAR
depends on HV_TERMINAL_BATTERY || HV_TERMINAL_NANOGRID
bool "Solar panel"
endchoice
choice
prompt "PWM terminal"
depends on $(dt_node_bool_prop,/outputs/pwm_switch,kconfig-flag)
help
Select the device connected to the PWM switch (currently
only solar panel possible)
config PWM_TERMINAL_SOLAR
depends on LV_TERMINAL_BATTERY && !HV_TERMINAL_SOLAR
bool "Solar panel"
endchoice
menu "Battery default settings"
config BAT_CAPACITY_AH
int "Battery nominal capacity in Ah"
range 10 1000
default 50
help
Nominal battery capacity or sum of parallel cells capacity
choice
prompt "Battery type"
default BAT_TYPE_GEL
help
Select the type of the single cells inside the battery
to determine voltage set points. Total voltage set points
are multiplied with the selected number of cells.
config BAT_TYPE_CUSTOM
bool "Custom type"
config BAT_TYPE_FLOODED
bool "Flooded (wet) lead-acid"
config BAT_TYPE_GEL
bool "VRLA gel, maintainance-free"
config BAT_TYPE_AGM
bool "AGM, maintainance-free"
config BAT_TYPE_LFP
bool "LiFePO4 Li-ion, 3.3V nominal"
config BAT_TYPE_NMC
bool "NMC/Graphite Li-ion, 3.7V nominal, 4.2V max"
config BAT_TYPE_NMC_HV
bool "NMC/Graphite High Voltage Li-ion, 3.7V nominal, 4.35 max"
endchoice
# values must match enum BatType in bat_charger.h
config BAT_TYPE
int
default 0 if BAT_TYPE_CUSTOM
default 1 if BAT_TYPE_FLOODED
default 2 if BAT_TYPE_GEL
default 3 if BAT_TYPE_AGM
default 4 if BAT_TYPE_LFP
default 5 if BAT_TYPE_NMC
default 6 if BAT_TYPE_NMC_HV
config BAT_NUM_CELLS
int "Number of cells for single battery"
default 6 if BAT_TYPE_FLOODED || BAT_TYPE_GEL || BAT_TYPE_AGM
default 4 if BAT_TYPE_LFP
default 3 if BAT_TYPE_NMC || BAT_TYPE_NMC_HV
range 3 16
help
Typical choices:
- 6 for 12V lead-acid battery
- 4 for 12V LiFePO4 battery
- 3 for 12V NMC Li-ion battery
Remarks:
- If you choose settings for 12V system, 24V systems
(2 batteries in series) are recognized automatically
- Make sure the voltage of the used charge controller
is not exceeded.
menu "Custom cell-level settings"
depends on BAT_TYPE_CUSTOM
config CELL_ABS_MAX_VOLTAGE_MV
int "Absolute maximum voltage (mV)"
default 2450
help
Above this voltage the battery or loads might get damaged.
config CELL_TOPPING_VOLTAGE_MV
int "Topping voltage (mV)"
default 2400
help
Charger target voltage, switching from CC to CV at this voltage threshold.
config CELL_RECHARGE_VOLTAGE_MV
int "Recharge voltage (mV)"
default 2300
help
Start charging again if voltage of fully charged battery drops below this threshold.
config CELL_RECONNECT_VOLTAGE_MV
int "Load reconnect cell voltage (mV)"
default 2100
help
Re-enable the load only after charged beyond this value.
config CELL_DISCONNECT_VOLTAGE_MV
int "Load disconnect cell voltage (mV)"
default 1950
help
Load output is disabled if battery voltage is below this threshold.
config CELL_ABS_MIN_VOLTAGE_MV
int "Topping voltage (mV)"
default 1600
help
Below this voltage the battery is considered damaged.
config CELL_OCV_FULL_MV
int "OCV full cell (mV)"
default 2150
help
Voltages during idle (no charging/discharging current)
config CELL_OCV_EMPTY_MV
int "OCV empty cell (mV)"
default 1900
help
Voltages during idle (no charging/discharging current)
config CELL_FLOAT
bool "Enable float charging phase"
default y
config CELL_FLOAT_VOLTAGE_MV
int "Float charging cell voltage (mV)" if CELL_FLOAT
default 2300
help
Charger target voltage for float charging of lead-acid batteries
config CELL_FLOAT_RECHARGE_TIME
int "Float recharge time (s)" if CELL_FLOAT
default 1800
help
If the float voltage is not reached anymore (e.g. because of lack of solar
input power) for this period of time, the charger state machine goes back
into CC/bulk charging mode.
config CELL_EQUALIZATION
bool "Enable equalization phase"
default n
help
Enable for flooded batteries only.
config CELL_EQUALIZATION_VOLTAGE_MV
int "Equalization phase cell voltage (mV)" if CELL_EQUALIZATION
default 2450
help
Charger target voltage for equalization charging of lead-acid batteries
config CELL_EQUALIZATION_DURATION
int "Equalization duration (seconds)" if CELL_EQUALIZATION
default 3600
help
After this time, equalization charging is stopped.
config CELL_EQUALIZATION_TRIGGER_DAYS
int "Equalization time trigger (days)" if CELL_EQUALIZATION
default 60
help
After passing specified amount of days, an equalization charge is triggered.
config CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES
int "Equalization deep cycle count trigger" if CELL_EQUALIZATION
default 10
help
After specified number of deep discharges, an equalization charge is triggered.
config CELL_TEMP_COMPENSATION_MV_K
int "Cell voltage temperature compenstaion (mV/K)"
range -5 0
default -3
help
Suggested value: -3 mV/K/cell for lead-acid batteries, 0 for Li-ion batteries
config CELL_INTERNAL_RESISTANCE_MOHM
int "Cell internal resistance (mOhm)"
range 1 30
default 5
endmenu # Custom cell-level settings
menu "Custom temperature settings"
depends on BAT_TYPE_CUSTOM
config BAT_CHARGE_TEMP_MAX
int "Maximum charge temperature (°C)"
range 0 60
default 50
config BAT_CHARGE_TEMP_MIN
int "Minimum charge temperature (°C)"
range -10 20
default 0
config BAT_DISCHARGE_TEMP_MAX
int "Maximum discharge temperature (°C)"
range 0 60
default 50
config BAT_DISCHARGE_TEMP_MIN
int "Minimum discharge temperature (°C)"
range -20 20
default -10
endmenu # Custom temperature settings
endmenu # Battery default settings
menu "Load output settings"
depends on $(dt_node_bool_prop,/outputs/load,kconfig-flag)
config LOAD_OC_RECOVERY_DELAY
int "Overcurrent recovery delay (s)"
default 300
config LOAD_LVD_RECOVERY_DELAY
int "Low-voltage disconnect recovery delay (s)"
default 300
help
Prevents toggling load output in case of heavy load and low state of charge.
endmenu # Load output settings
endmenu # Charge controller setup
menu "UEXT port"
config UEXT_OLED_DISPLAY
select I2C
bool "OLED display"
config UEXT_OLED_BRIGHTNESS
depends on UEXT_OLED_DISPLAY
int "OLED display brightness"
range 1 255
default 1
endmenu # UEXT port
menu "Logging setup"
config CAN_LOG_LEVEL
int "Log level for the CAN module (if included)"
default 2
depends on LOG
help
Log level for the CAN module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config DAQ_LOG_LEVEL
int "Log level for the DAQ module"
default 2
depends on LOG
help
Log level for the DAQ module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config DATA_OBJECTS_LOG_LEVEL
int "Log level for the data objects module"
default 2
depends on LOG
help
Log level for the data nodes module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config DATA_STORAGE_LOG_LEVEL
int "Log level for the data storage module"
default 2
depends on LOG
help
Log level for the data storage module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config DCDC_LOG_LEVEL
int "Log level for the DCDC module (if included)"
default 2
depends on LOG
help
Log level for the DCDC module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config HW_LOG_LEVEL
int "Log level for the hardware module"
default 2
depends on LOG
help
Log level for the hardware module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config BAT_LOG_LEVEL
int "Log level for the battery module"
default 2
depends on LOG
help
Log level for the battery module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
config PWM_LOG_LEVEL
int "Log level for the PWM module (if included)"
default 2
depends on LOG
help
Log level for the PWM module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
endmenu # Logging setup
menuconfig CUSTOMIZATION
bool "Firmware customization"
help
Activating this option allows to overwrite existing firmware functions
or add customizations independent of the main branch.
Custom implementations should be stored in the
src/custom subdirectory.
if CUSTOMIZATION
config CUSTOM_DATA_OBJECTS_FILE
bool "Use custom data nodes file"
default n
help
Use the file data_objects_custom.cpp instead of the default data_objects.cpp
for ThingSet configuration.
config CUSTOM_DCDC_CONTROLLER
bool "Custom implementation of DC/DC controller"
depends on $(dt_compat_enabled,half-bridge)
default n
help
Use a custom implementation instead of the default perturb & observe
MPPT control.
endif