mainmenu "Libre Solar Charge Controller Firmware"
|
|
|
|
#
|
|
# Invisible (board-specific) Kconfig symbols
|
|
#
|
|
|
|
config CONTROL_FREQUENCY
|
|
int
|
|
default 10
|
|
help
|
|
Main control function frequency (Hz)
|
|
|
|
Frequencies higher than 10 Hz caused issues with MPPT control during lab test with
|
|
PV simulator. Might be different with actual solar panel.
|
|
|
|
config LIBRE_SOLAR_TYPE_ID
|
|
int
|
|
help
|
|
Numeric Libre Solar hardware type ID
|
|
|
|
config HS_MOSFET_FAIL_SAFE_PROTECTION
|
|
bool
|
|
default y
|
|
help
|
|
If enabled, the DC/DC control function will will detect if the high-side MOSFET has failed
|
|
short and trip the fuse by switching the low-side MOSFET continuously on. This will prevent
|
|
accidental overcharging of the battery.
|
|
|
|
#
|
|
# Visible (user-configurable) Kconfig symbols
|
|
#
|
|
|
|
menu "Charge Controller Setup"
|
|
|
|
choice
|
|
prompt "High-voltage terminal"
|
|
depends on $(dt_compat_enabled,half-bridge)
|
|
help
|
|
Select the device connected to the high-voltage
|
|
side terminal of the DC/DC converter.
|
|
|
|
config HV_TERMINAL_SOLAR
|
|
bool "Solar panel"
|
|
|
|
config HV_TERMINAL_NANOGRID
|
|
bool "DC nanogrid"
|
|
|
|
config HV_TERMINAL_GENERATOR
|
|
bool "DC generator, e.g. wind turbine"
|
|
|
|
config HV_TERMINAL_BATTERY
|
|
bool "Battery, e.g. electric bicycle"
|
|
endchoice
|
|
|
|
|
|
choice
|
|
prompt "Low-voltage terminal"
|
|
help
|
|
Select the device connected to the low-voltage side
|
|
of the charge controller (usually battery terminal).
|
|
|
|
config LV_TERMINAL_BATTERY
|
|
depends on !HV_TERMINAL_BATTERY
|
|
bool "Battery 12V/24V"
|
|
|
|
config LV_TERMINAL_SOLAR
|
|
depends on HV_TERMINAL_BATTERY || HV_TERMINAL_NANOGRID
|
|
bool "Solar panel"
|
|
endchoice
|
|
|
|
|
|
choice
|
|
prompt "PWM terminal"
|
|
depends on $(dt_node_bool_prop,/outputs/pwm_switch,kconfig-flag)
|
|
help
|
|
Select the device connected to the PWM switch (currently
|
|
only solar panel possible)
|
|
|
|
config PWM_TERMINAL_SOLAR
|
|
depends on LV_TERMINAL_BATTERY && !HV_TERMINAL_SOLAR
|
|
bool "Solar panel"
|
|
endchoice
|
|
|
|
|
|
menu "Battery default settings"
|
|
|
|
config BAT_CAPACITY_AH
|
|
int "Battery nominal capacity in Ah"
|
|
range 10 1000
|
|
default 50
|
|
help
|
|
Nominal battery capacity or sum of parallel cells capacity
|
|
|
|
choice
|
|
prompt "Battery type"
|
|
default BAT_TYPE_GEL
|
|
help
|
|
Select the type of the single cells inside the battery
|
|
to determine voltage set points. Total voltage set points
|
|
are multiplied with the selected number of cells.
|
|
|
|
config BAT_TYPE_CUSTOM
|
|
bool "Custom type"
|
|
|
|
config BAT_TYPE_FLOODED
|
|
bool "Flooded (wet) lead-acid"
|
|
|
|
config BAT_TYPE_GEL
|
|
bool "VRLA gel, maintainance-free"
|
|
|
|
config BAT_TYPE_AGM
|
|
bool "AGM, maintainance-free"
|
|
|
|
config BAT_TYPE_LFP
|
|
bool "LiFePO4 Li-ion, 3.3V nominal"
|
|
|
|
config BAT_TYPE_NMC
|
|
bool "NMC/Graphite Li-ion, 3.7V nominal, 4.2V max"
|
|
|
|
config BAT_TYPE_NMC_HV
|
|
bool "NMC/Graphite High Voltage Li-ion, 3.7V nominal, 4.35 max"
|
|
endchoice
|
|
|
|
# values must match enum BatType in bat_charger.h
|
|
config BAT_TYPE
|
|
int
|
|
default 0 if BAT_TYPE_CUSTOM
|
|
default 1 if BAT_TYPE_FLOODED
|
|
default 2 if BAT_TYPE_GEL
|
|
default 3 if BAT_TYPE_AGM
|
|
default 4 if BAT_TYPE_LFP
|
|
default 5 if BAT_TYPE_NMC
|
|
default 6 if BAT_TYPE_NMC_HV
|
|
|
|
config BAT_NUM_CELLS
|
|
int "Number of cells for single battery"
|
|
default 6 if BAT_TYPE_FLOODED || BAT_TYPE_GEL || BAT_TYPE_AGM
|
|
default 4 if BAT_TYPE_LFP
|
|
default 3 if BAT_TYPE_NMC || BAT_TYPE_NMC_HV
|
|
range 3 16
|
|
help
|
|
Typical choices:
|
|
- 6 for 12V lead-acid battery
|
|
- 4 for 12V LiFePO4 battery
|
|
- 3 for 12V NMC Li-ion battery
|
|
|
|
Remarks:
|
|
- If you choose settings for 12V system, 24V systems
|
|
(2 batteries in series) are recognized automatically
|
|
- Make sure the voltage of the used charge controller
|
|
is not exceeded.
|
|
|
|
menu "Custom cell-level settings"
|
|
depends on BAT_TYPE_CUSTOM
|
|
|
|
config CELL_ABS_MAX_VOLTAGE_MV
|
|
int "Absolute maximum voltage (mV)"
|
|
default 2450
|
|
help
|
|
Above this voltage the battery or loads might get damaged.
|
|
|
|
config CELL_TOPPING_VOLTAGE_MV
|
|
int "Topping voltage (mV)"
|
|
default 2400
|
|
help
|
|
Charger target voltage, switching from CC to CV at this voltage threshold.
|
|
|
|
config CELL_RECHARGE_VOLTAGE_MV
|
|
int "Recharge voltage (mV)"
|
|
default 2300
|
|
help
|
|
Start charging again if voltage of fully charged battery drops below this threshold.
|
|
|
|
config CELL_RECONNECT_VOLTAGE_MV
|
|
int "Load reconnect cell voltage (mV)"
|
|
default 2100
|
|
help
|
|
Re-enable the load only after charged beyond this value.
|
|
|
|
config CELL_DISCONNECT_VOLTAGE_MV
|
|
int "Load disconnect cell voltage (mV)"
|
|
default 1950
|
|
help
|
|
Load output is disabled if battery voltage is below this threshold.
|
|
|
|
config CELL_ABS_MIN_VOLTAGE_MV
|
|
int "Topping voltage (mV)"
|
|
default 1600
|
|
help
|
|
Below this voltage the battery is considered damaged.
|
|
|
|
config CELL_OCV_FULL_MV
|
|
int "OCV full cell (mV)"
|
|
default 2150
|
|
help
|
|
Voltages during idle (no charging/discharging current)
|
|
|
|
config CELL_OCV_EMPTY_MV
|
|
int "OCV empty cell (mV)"
|
|
default 1900
|
|
help
|
|
Voltages during idle (no charging/discharging current)
|
|
|
|
config CELL_FLOAT
|
|
bool "Enable float charging phase"
|
|
default y
|
|
|
|
config CELL_FLOAT_VOLTAGE_MV
|
|
int "Float charging cell voltage (mV)" if CELL_FLOAT
|
|
default 2300
|
|
help
|
|
Charger target voltage for float charging of lead-acid batteries
|
|
|
|
config CELL_FLOAT_RECHARGE_TIME
|
|
int "Float recharge time (s)" if CELL_FLOAT
|
|
default 1800
|
|
help
|
|
If the float voltage is not reached anymore (e.g. because of lack of solar
|
|
input power) for this period of time, the charger state machine goes back
|
|
into CC/bulk charging mode.
|
|
|
|
config CELL_EQUALIZATION
|
|
bool "Enable equalization phase"
|
|
default n
|
|
help
|
|
Enable for flooded batteries only.
|
|
|
|
config CELL_EQUALIZATION_VOLTAGE_MV
|
|
int "Equalization phase cell voltage (mV)" if CELL_EQUALIZATION
|
|
default 2450
|
|
help
|
|
Charger target voltage for equalization charging of lead-acid batteries
|
|
|
|
config CELL_EQUALIZATION_DURATION
|
|
int "Equalization duration (seconds)" if CELL_EQUALIZATION
|
|
default 3600
|
|
help
|
|
After this time, equalization charging is stopped.
|
|
|
|
config CELL_EQUALIZATION_TRIGGER_DAYS
|
|
int "Equalization time trigger (days)" if CELL_EQUALIZATION
|
|
default 60
|
|
help
|
|
After passing specified amount of days, an equalization charge is triggered.
|
|
|
|
config CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES
|
|
int "Equalization deep cycle count trigger" if CELL_EQUALIZATION
|
|
default 10
|
|
help
|
|
After specified number of deep discharges, an equalization charge is triggered.
|
|
|
|
config CELL_TEMP_COMPENSATION_MV_K
|
|
int "Cell voltage temperature compenstaion (mV/K)"
|
|
range -5 0
|
|
default -3
|
|
help
|
|
Suggested value: -3 mV/K/cell for lead-acid batteries, 0 for Li-ion batteries
|
|
|
|
config CELL_INTERNAL_RESISTANCE_MOHM
|
|
int "Cell internal resistance (mOhm)"
|
|
range 1 30
|
|
default 5
|
|
|
|
endmenu # Custom cell-level settings
|
|
|
|
menu "Custom temperature settings"
|
|
depends on BAT_TYPE_CUSTOM
|
|
|
|
config BAT_CHARGE_TEMP_MAX
|
|
int "Maximum charge temperature (°C)"
|
|
range 0 60
|
|
default 50
|
|
|
|
config BAT_CHARGE_TEMP_MIN
|
|
int "Minimum charge temperature (°C)"
|
|
range -10 20
|
|
default 0
|
|
|
|
config BAT_DISCHARGE_TEMP_MAX
|
|
int "Maximum discharge temperature (°C)"
|
|
range 0 60
|
|
default 50
|
|
|
|
config BAT_DISCHARGE_TEMP_MIN
|
|
int "Minimum discharge temperature (°C)"
|
|
range -20 20
|
|
default -10
|
|
|
|
endmenu # Custom temperature settings
|
|
|
|
endmenu # Battery default settings
|
|
|
|
|
|
menu "Load output settings"
|
|
depends on $(dt_node_bool_prop,/outputs/load,kconfig-flag)
|
|
|
|
config LOAD_OC_RECOVERY_DELAY
|
|
int "Overcurrent recovery delay (s)"
|
|
default 300
|
|
|
|
config LOAD_LVD_RECOVERY_DELAY
|
|
int "Low-voltage disconnect recovery delay (s)"
|
|
default 300
|
|
help
|
|
Prevents toggling load output in case of heavy load and low state of charge.
|
|
|
|
endmenu # Load output settings
|
|
|
|
|
|
endmenu # Charge controller setup
|
|
|
|
|
|
menu "UEXT port"
|
|
|
|
config UEXT_OLED_DISPLAY
|
|
select I2C
|
|
bool "OLED display"
|
|
|
|
config UEXT_OLED_BRIGHTNESS
|
|
depends on UEXT_OLED_DISPLAY
|
|
int "OLED display brightness"
|
|
range 1 255
|
|
default 1
|
|
|
|
endmenu # UEXT port
|
|
|
|
menu "Logging setup"
|
|
|
|
config CAN_LOG_LEVEL
|
|
int "Log level for the CAN module (if included)"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the CAN module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config DAQ_LOG_LEVEL
|
|
int "Log level for the DAQ module"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the DAQ module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config DATA_OBJECTS_LOG_LEVEL
|
|
int "Log level for the data objects module"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the data nodes module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config DATA_STORAGE_LOG_LEVEL
|
|
int "Log level for the data storage module"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the data storage module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config DCDC_LOG_LEVEL
|
|
int "Log level for the DCDC module (if included)"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the DCDC module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config HW_LOG_LEVEL
|
|
int "Log level for the hardware module"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the hardware module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config BAT_LOG_LEVEL
|
|
int "Log level for the battery module"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the battery module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
config PWM_LOG_LEVEL
|
|
int "Log level for the PWM module (if included)"
|
|
default 2
|
|
depends on LOG
|
|
help
|
|
Log level for the PWM module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG
|
|
|
|
endmenu # Logging setup
|
|
|
|
menuconfig CUSTOMIZATION
|
|
bool "Firmware customization"
|
|
help
|
|
Activating this option allows to overwrite existing firmware functions
|
|
or add customizations independent of the main branch.
|
|
Custom implementations should be stored in the
|
|
src/custom subdirectory.
|
|
|
|
if CUSTOMIZATION
|
|
|
|
config CUSTOM_DATA_OBJECTS_FILE
|
|
bool "Use custom data nodes file"
|
|
default n
|
|
help
|
|
Use the file data_objects_custom.cpp instead of the default data_objects.cpp
|
|
for ThingSet configuration.
|
|
|
|
config CUSTOM_DCDC_CONTROLLER
|
|
bool "Custom implementation of DC/DC controller"
|
|
depends on $(dt_compat_enabled,half-bridge)
|
|
default n
|
|
help
|
|
Use a custom implementation instead of the default perturb & observe
|
|
MPPT control.
|
|
|
|
endif
|
|
|
|
# include custom Kconfig if existing
|
|
orsource "../src/custom/Kconfig"
|
|
|
|
# include main Zephyr menu entries from Zephyr root directory
|
|
source "Kconfig.zephyr"
|