# Copyright (c) The Libre Solar Project Contributors # SPDX-License-Identifier: Apache-2.0 mainmenu "Libre Solar Charge Controller Firmware" # # Invisible (board-specific) Kconfig symbols # config CONTROL_FREQUENCY int default 10 help Main control function frequency (Hz) Frequencies higher than 10 Hz caused issues with MPPT control during lab test with PV simulator. Might be different with actual solar panel. config LIBRE_SOLAR_TYPE_ID int help Numeric Libre Solar hardware type ID config HS_MOSFET_FAIL_SAFE_PROTECTION bool default y help If enabled, the DC/DC control function will will detect if the high-side MOSFET has failed short and trip the fuse by switching the low-side MOSFET continuously on. This will prevent accidental overcharging of the battery. # # Visible (user-configurable) Kconfig symbols # menu "Charge Controller Setup" choice prompt "High-voltage terminal" depends on $(dt_compat_enabled,half-bridge) help Select the device connected to the high-voltage side terminal of the DC/DC converter. config HV_TERMINAL_SOLAR bool "Solar panel" config HV_TERMINAL_NANOGRID bool "DC nanogrid" config HV_TERMINAL_GENERATOR bool "DC generator, e.g. wind turbine" config HV_TERMINAL_BATTERY bool "Battery, e.g. electric bicycle" endchoice choice prompt "Low-voltage terminal" help Select the device connected to the low-voltage side of the charge controller (usually battery terminal). config LV_TERMINAL_BATTERY depends on !HV_TERMINAL_BATTERY bool "Battery 12V/24V" config LV_TERMINAL_SOLAR depends on HV_TERMINAL_BATTERY || HV_TERMINAL_NANOGRID bool "Solar panel" endchoice choice prompt "PWM terminal" depends on $(dt_node_bool_prop,/outputs/pwm_switch,kconfig-flag) help Select the device connected to the PWM switch (currently only solar panel possible) config PWM_TERMINAL_SOLAR depends on LV_TERMINAL_BATTERY && !HV_TERMINAL_SOLAR bool "Solar panel" endchoice menu "Battery default settings" config BAT_CAPACITY_AH int "Battery nominal capacity in Ah" range 10 1000 default 50 help Nominal battery capacity or sum of parallel cells capacity choice prompt "Battery type" default BAT_TYPE_GEL help Select the type of the single cells inside the battery to determine voltage set points. Total voltage set points are multiplied with the selected number of cells. config BAT_TYPE_CUSTOM bool "Custom type" config BAT_TYPE_FLOODED bool "Flooded (wet) lead-acid" config BAT_TYPE_GEL bool "VRLA gel, maintainance-free" config BAT_TYPE_AGM bool "AGM, maintainance-free" config BAT_TYPE_LFP bool "LiFePO4 Li-ion, 3.3V nominal" config BAT_TYPE_NMC bool "NMC/Graphite Li-ion, 3.7V nominal, 4.2V max" config BAT_TYPE_NMC_HV bool "NMC/Graphite High Voltage Li-ion, 3.7V nominal, 4.35 max" endchoice # values must match enum BatType in bat_charger.h config BAT_TYPE int default 0 if BAT_TYPE_CUSTOM default 1 if BAT_TYPE_FLOODED default 2 if BAT_TYPE_GEL default 3 if BAT_TYPE_AGM default 4 if BAT_TYPE_LFP default 5 if BAT_TYPE_NMC default 6 if BAT_TYPE_NMC_HV config BAT_NUM_CELLS int "Number of cells for single battery" default 6 if BAT_TYPE_FLOODED || BAT_TYPE_GEL || BAT_TYPE_AGM default 4 if BAT_TYPE_LFP default 3 if BAT_TYPE_NMC || BAT_TYPE_NMC_HV range 3 16 help Typical choices: - 6 for 12V lead-acid battery - 4 for 12V LiFePO4 battery - 3 for 12V NMC Li-ion battery Remarks: - If you choose settings for 12V system, 24V systems (2 batteries in series) are recognized automatically - Make sure the voltage of the used charge controller is not exceeded. menu "Custom cell-level settings" depends on BAT_TYPE_CUSTOM config CELL_ABS_MAX_VOLTAGE_MV int "Absolute maximum voltage (mV)" default 2450 help Above this voltage the battery or loads might get damaged. config CELL_TOPPING_VOLTAGE_MV int "Topping voltage (mV)" default 2400 help Charger target voltage, switching from CC to CV at this voltage threshold. config CELL_RECHARGE_VOLTAGE_MV int "Recharge voltage (mV)" default 2300 help Start charging again if voltage of fully charged battery drops below this threshold. config CELL_RECONNECT_VOLTAGE_MV int "Load reconnect cell voltage (mV)" default 2100 help Re-enable the load only after charged beyond this value. config CELL_DISCONNECT_VOLTAGE_MV int "Load disconnect cell voltage (mV)" default 1950 help Load output is disabled if battery voltage is below this threshold. config CELL_ABS_MIN_VOLTAGE_MV int "Topping voltage (mV)" default 1600 help Below this voltage the battery is considered damaged. config CELL_OCV_FULL_MV int "OCV full cell (mV)" default 2150 help Voltages during idle (no charging/discharging current) config CELL_OCV_EMPTY_MV int "OCV empty cell (mV)" default 1900 help Voltages during idle (no charging/discharging current) config CELL_FLOAT bool "Enable float charging phase" default y config CELL_FLOAT_VOLTAGE_MV int "Float charging cell voltage (mV)" if CELL_FLOAT default 2300 help Charger target voltage for float charging of lead-acid batteries config CELL_FLOAT_RECHARGE_TIME int "Float recharge time (s)" if CELL_FLOAT default 1800 help If the float voltage is not reached anymore (e.g. because of lack of solar input power) for this period of time, the charger state machine goes back into CC/bulk charging mode. config CELL_EQUALIZATION bool "Enable equalization phase" default n help Enable for flooded batteries only. config CELL_EQUALIZATION_VOLTAGE_MV int "Equalization phase cell voltage (mV)" if CELL_EQUALIZATION default 2450 help Charger target voltage for equalization charging of lead-acid batteries config CELL_EQUALIZATION_DURATION int "Equalization duration (seconds)" if CELL_EQUALIZATION default 3600 help After this time, equalization charging is stopped. config CELL_EQUALIZATION_TRIGGER_DAYS int "Equalization time trigger (days)" if CELL_EQUALIZATION default 60 help After passing specified amount of days, an equalization charge is triggered. config CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES int "Equalization deep cycle count trigger" if CELL_EQUALIZATION default 10 help After specified number of deep discharges, an equalization charge is triggered. config CELL_TEMP_COMPENSATION_MV_K int "Cell voltage temperature compenstaion (mV/K)" range -5 0 default -3 help Suggested value: -3 mV/K/cell for lead-acid batteries, 0 for Li-ion batteries config CELL_INTERNAL_RESISTANCE_MOHM int "Cell internal resistance (mOhm)" range 1 30 default 5 endmenu # Custom cell-level settings menu "Custom temperature settings" depends on BAT_TYPE_CUSTOM config BAT_CHARGE_TEMP_MAX int "Maximum charge temperature (°C)" range 0 60 default 50 config BAT_CHARGE_TEMP_MIN int "Minimum charge temperature (°C)" range -10 20 default 0 config BAT_DISCHARGE_TEMP_MAX int "Maximum discharge temperature (°C)" range 0 60 default 50 config BAT_DISCHARGE_TEMP_MIN int "Minimum discharge temperature (°C)" range -20 20 default -10 endmenu # Custom temperature settings endmenu # Battery default settings menu "Load output settings" depends on $(dt_node_bool_prop,/outputs/load,kconfig-flag) config LOAD_OC_RECOVERY_DELAY int "Overcurrent recovery delay (s)" default 300 config LOAD_LVD_RECOVERY_DELAY int "Low-voltage disconnect recovery delay (s)" default 300 help Prevents toggling load output in case of heavy load and low state of charge. endmenu # Load output settings endmenu # Charge controller setup menu "UEXT port" config UEXT_OLED_DISPLAY select I2C bool "OLED display" config UEXT_OLED_BRIGHTNESS depends on UEXT_OLED_DISPLAY int "OLED display brightness" range 1 255 default 1 endmenu # UEXT port menu "Logging setup" config CAN_LOG_LEVEL int "Log level for the CAN module (if included)" default 2 depends on LOG help Log level for the CAN module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config DAQ_LOG_LEVEL int "Log level for the DAQ module" default 2 depends on LOG help Log level for the DAQ module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config DATA_OBJECTS_LOG_LEVEL int "Log level for the data objects module" default 2 depends on LOG help Log level for the data nodes module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config DATA_STORAGE_LOG_LEVEL int "Log level for the data storage module" default 2 depends on LOG help Log level for the data storage module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config DCDC_LOG_LEVEL int "Log level for the DCDC module (if included)" default 2 depends on LOG help Log level for the DCDC module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config HW_LOG_LEVEL int "Log level for the hardware module" default 2 depends on LOG help Log level for the hardware module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config BAT_LOG_LEVEL int "Log level for the battery module" default 2 depends on LOG help Log level for the battery module. 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG config PWM_LOG_LEVEL int "Log level for the PWM module (if included)" default 2 depends on LOG help Log level for the PWM module (if included). 0=off, 1=ERR, 2=WRN, 3=INF, 4=DBG endmenu # Logging setup menuconfig CUSTOMIZATION bool "Firmware customization" help Activating this option allows to overwrite existing firmware functions or add customizations independent of the main branch. Custom implementations should be stored in the src/custom subdirectory. if CUSTOMIZATION config CUSTOM_DATA_OBJECTS_FILE bool "Use custom data nodes file" default n help Use the file data_objects_custom.cpp instead of the default data_objects.cpp for ThingSet configuration. config CUSTOM_DCDC_CONTROLLER bool "Custom implementation of DC/DC controller" depends on $(dt_compat_enabled,half-bridge) default n help Use a custom implementation instead of the default perturb & observe MPPT control. endif # include custom Kconfig if existing orsource "../src/custom/Kconfig" # include main Zephyr menu entries from Zephyr root directory source "Kconfig.zephyr"