13 Commits
Author SHA1 Message Date
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger 74b765e801 Trailing white spaces removed 2019-11-21 07:44:15 +01:00
Martin Jaeger a7239fa9bb Enabled all warnings for unit-test builds 2019-10-24 16:10:35 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 0545131a99 Equalization charging phase added 2019-10-16 10:02:27 +02:00
Martin Jaeger 25e469516c DC/DC control functions cleaned up 2019-10-15 14:00:20 +02:00
Martin Jaeger ae51d7a0d7 Unit tests for DC/DC control added 2019-10-15 13:59:48 +02:00
Martin Jaeger e7317ae1d8 DC bus and terminal naming improved
- DcBus representing actual screw terminals renamed
- Internal DC bus at DC/DC low voltage side added for correct DC/DC control
- DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed.
- Unit tests updated

DC/DC control needs further improvements to make use of the changes
2019-10-15 13:57:23 +02:00
Martin Jaeger cb206b6864 DC/DC startup check reworked and unit-tests added 2019-10-15 13:54:05 +02:00