- DcBus representing actual screw terminals renamed - Internal DC bus at DC/DC low voltage side added for correct DC/DC control - DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed. - Unit tests updated DC/DC control needs further improvements to make use of the changes
191 lines
4.7 KiB
C++
191 lines
4.7 KiB
C++
|
|
#include "tests.h"
|
|
|
|
#include "dcdc.h"
|
|
#include "dc_bus.h"
|
|
#include "log.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
#include <math.h>
|
|
|
|
extern Dcdc dcdc;
|
|
extern DcBus hv_terminal;
|
|
extern DcBus lv_bus_int;
|
|
extern BatConf bat_conf;
|
|
|
|
static void init_structs_buck()
|
|
{
|
|
dc_bus_init_solar(&hv_terminal, 10);
|
|
hv_terminal.voltage = 20;
|
|
hv_terminal.dis_voltage_start = 18;
|
|
|
|
battery_conf_init(&bat_conf, BAT_TYPE_GEL, 6, 100);
|
|
battery_init_dc_bus(&lv_bus_int, &bat_conf, 1);
|
|
lv_bus_int.voltage = 14;
|
|
|
|
dcdc_init(&dcdc, &hv_terminal, &lv_bus_int);
|
|
}
|
|
|
|
static void init_structs_boost()
|
|
{
|
|
dc_bus_init_solar(&lv_bus_int, 10);
|
|
lv_bus_int.voltage = 20;
|
|
lv_bus_int.dis_voltage_start = 18;
|
|
|
|
battery_conf_init(&bat_conf, BAT_TYPE_NMC, 10, 9);
|
|
battery_init_dc_bus(&hv_terminal, &bat_conf, 1);
|
|
hv_terminal.voltage = 3.7 * 10;
|
|
|
|
dcdc_init(&dcdc, &hv_terminal, &lv_bus_int);
|
|
}
|
|
|
|
void start_valid_mppt_buck()
|
|
{
|
|
init_structs_buck();
|
|
TEST_ASSERT_EQUAL(1, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void start_valid_mppt_boost()
|
|
{
|
|
init_structs_boost();
|
|
TEST_ASSERT_EQUAL(-1, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_start_before_restart_delay()
|
|
{
|
|
init_structs_buck();
|
|
dcdc.off_timestamp = time(NULL) - dcdc.restart_interval + 1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
dcdc.off_timestamp = time(NULL) - dcdc.restart_interval;
|
|
TEST_ASSERT_EQUAL(1, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_start_if_dcdc_disabled()
|
|
{
|
|
init_structs_buck();
|
|
dcdc.enabled = false;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_start_if_dcdc_lv_voltage_low()
|
|
{
|
|
init_structs_buck();
|
|
lv_bus_int.voltage = dcdc.ls_voltage_min - 0.5;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
// buck
|
|
|
|
void no_buck_start_if_bat_voltage_low()
|
|
{
|
|
init_structs_buck();
|
|
lv_bus_int.voltage = bat_conf.voltage_absolute_min - 0.1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_buck_start_if_bat_voltage_high()
|
|
{
|
|
init_structs_buck();
|
|
lv_bus_int.voltage = bat_conf.voltage_topping + 0.1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_buck_start_if_bat_chg_not_allowed()
|
|
{
|
|
init_structs_buck();
|
|
lv_bus_int.chg_current_max = 0;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_buck_start_if_solar_voltage_high()
|
|
{
|
|
init_structs_buck();
|
|
hv_terminal.voltage = dcdc.hs_voltage_max + 1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_buck_start_if_solar_voltage_low()
|
|
{
|
|
init_structs_buck();
|
|
hv_terminal.voltage = 17;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
// boost
|
|
|
|
void no_boost_start_if_bat_voltage_low()
|
|
{
|
|
init_structs_boost();
|
|
hv_terminal.voltage = bat_conf.voltage_absolute_min - 0.1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_boost_start_if_bat_voltage_high()
|
|
{
|
|
init_structs_boost();
|
|
hv_terminal.voltage = bat_conf.voltage_topping + 0.1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_boost_start_if_bat_chg_not_allowed()
|
|
{
|
|
init_structs_boost();
|
|
hv_terminal.chg_current_max = 0;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_boost_start_if_solar_voltage_high()
|
|
{
|
|
init_structs_boost();
|
|
lv_bus_int.voltage = dcdc.ls_voltage_max + 1;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void no_boost_start_if_solar_voltage_low()
|
|
{
|
|
init_structs_boost();
|
|
lv_bus_int.voltage = 17;
|
|
TEST_ASSERT_EQUAL(0, dcdc_check_start_conditions(&dcdc));
|
|
}
|
|
|
|
void dcdc_tests()
|
|
{
|
|
UNITY_BEGIN();
|
|
|
|
// 1. Check of general (re)start conditions
|
|
|
|
// check if initialization of test is correct and we start at all
|
|
RUN_TEST(start_valid_mppt_buck);
|
|
RUN_TEST(start_valid_mppt_boost);
|
|
|
|
RUN_TEST(no_start_before_restart_delay);
|
|
RUN_TEST(no_start_if_dcdc_disabled);
|
|
RUN_TEST(no_start_if_dcdc_lv_voltage_low);
|
|
|
|
// 2. Check startup for MPPT buck converter scenario
|
|
|
|
RUN_TEST(no_buck_start_if_bat_voltage_low);
|
|
RUN_TEST(no_buck_start_if_bat_voltage_high);
|
|
RUN_TEST(no_buck_start_if_bat_chg_not_allowed);
|
|
RUN_TEST(no_buck_start_if_solar_voltage_high);
|
|
RUN_TEST(no_buck_start_if_solar_voltage_low);
|
|
|
|
// 3. Check startup for MPPT boost converter scenario
|
|
|
|
RUN_TEST(no_boost_start_if_bat_voltage_low);
|
|
RUN_TEST(no_boost_start_if_bat_voltage_high);
|
|
RUN_TEST(no_boost_start_if_bat_chg_not_allowed);
|
|
RUN_TEST(no_boost_start_if_solar_voltage_high);
|
|
RUN_TEST(no_boost_start_if_solar_voltage_low);
|
|
|
|
// 4. Check startup for nanogrid scenario
|
|
|
|
// TODO
|
|
|
|
// 5. Check DC/DC control after being started
|
|
|
|
// TODO
|
|
|
|
UNITY_END();
|
|
} |