- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
- Switched back to older mbed version, as update broke comparator function
- Added voltage dip detection to disconnect load if charge controller is connected to small
battery or with bad wires and short circuit detection doesn't trigger
- Added more error flags to diagnose reasons for load disconnect
- Charge/discharge control in charger class sets global error flags
- Load state machine analyzes error flags to distinguish reasons for switching load off
- Temperature errors now identified correctly (issue #59)
- Delay before load re-connect after low voltage or overcurrent event now configurable
- Unit tests added