Identified issues:
- The load output and USB charging port shared the same state machine,
which did not allow to set different switch-off thresholds.
- Load error codes were global, so it was not possible to have multiple
load instances.
This commit introduces load-specific error_flags, makes the LoadOutput
class inherit from PowerPort (to improve code readability), separates
the load driver better from higher level implementation and adds a
second LoadOutput object for the USB charging port.
First step of unifying different ports connected to one bus. At a later
step, also the load and charger classes should inherit from PowerPort
class to make overall charge controller structure more clean.
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.