Commit Graph
16 Commits
Author SHA1 Message Date
Martin Jaeger a7239fa9bb Enabled all warnings for unit-test builds 2019-10-24 16:10:35 +02:00
Martin Jaeger 42751c83c2 PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
2019-10-23 10:32:48 +02:00
Martin Jaeger f879dc9c5d DC bus integrated into PowerPort class
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
2019-10-22 18:23:19 +02:00
Martin Jaeger 8558cef9cb PWM switch also implemented as class 2019-10-20 22:01:45 +02:00
Martin Jaeger b5c7f396e1 PowerPort configuration for different charger types improved
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
2019-10-20 17:44:32 +02:00
Martin Jaeger 0399c4e877 PowerPort added to store current independent from DC bus type
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.

With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
2019-10-20 14:52:35 +02:00
Martin Jaeger f33146e9de Battery discharging control restructured
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
2019-10-16 16:04:21 +02:00
Martin Jaeger 3f4f52ea18 PWM switch: Bug fixed + some improvements
- Serious bug: Switch did not go below 90% duty cycle (left-over from testing code). Could result in overcharging of battery.
- Improvement: Preventing very short on/off times (duty cycles close to 0 or 1) as switching time is quite slow
- PWM frequency now configurable via PCB config (and increased from 20 to 25 Hz)
- Some unused parameters in PwmSwitch struct removed and variables renamed
- Overcurrent setting now via solar_bus
2019-08-16 11:37:25 +02:00
Martin Jaeger c968a6bb8a Structs renamed for new coding style (closes #42) 2019-08-08 10:16:16 +02:00
Martin Jaeger dec36143dd 12V/24V detection added and bat_charger restructured 2019-05-23 22:16:41 +02:00
Martin Jaeger b742fe6671 Energy calculation for PWM CC fixed
- Correct negative sign for incoming solar current
- Current multiplied with PWM duty cycle to get average current
- Min/max calculation moved to log.cpp
2019-05-15 11:06:49 +02:00
Martin Jaeger 7c75548193 DC bus type introduced and unit tests added 2019-05-07 18:56:04 +02:00
Martin Jaeger d9f7103e97 Starting test-driven development (TDD) with Unity
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory
2019-05-04 11:31:37 +02:00
Martin Jaeger e05fd95e17 Current compensation for load switch thresholds added 2019-04-18 09:23:58 +02:00
Martin Jaeger 666ca02baf Min/max recordings added to serial pub message 2019-04-17 08:18:44 +02:00
Martin Jaeger 627797ed36 PWM synchronized solar current/voltage measurement implemented 2019-04-01 20:09:27 +02:00