Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.
With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
- Serious bug: Switch did not go below 90% duty cycle (left-over from testing code). Could result in overcharging of battery.
- Improvement: Preventing very short on/off times (duty cycles close to 0 or 1) as switching time is quite slow
- PWM frequency now configurable via PCB config (and increased from 20 to 25 Hz)
- Some unused parameters in PwmSwitch struct removed and variables renamed
- Overcurrent setting now via solar_bus
- Correct negative sign for incoming solar current
- Current multiplied with PWM duty cycle to get average current
- Min/max calculation moved to log.cpp
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory