Martin Jäger fa9d15e796 Separate load and USB out, improve state handling
Identified issues:
- The load output and USB charging port shared the same state machine,
  which did not allow to set different switch-off thresholds.
- Load error codes were global, so it was not possible to have multiple
  load instances.

This commit introduces load-specific error_flags, makes the LoadOutput
class inherit from PowerPort (to improve code readability), separates
the load driver better from higher level implementation and adds a
second LoadOutput object for the USB charging port.
2020-02-21 18:27:36 +01:00
Martin Jaeger 5f1d76ef74 Dedicated setup.cpp to clean up main.cpp
Also includes update of timestamp calculation in Zephyr.
2020-02-08 11:08:58 +01:00
Martin Jaeger f0e99cd80f Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control
parameters into DcBus and PowerPort classes. This will help to
manage current from different sources (grid, solar) going towards
one bus and control the battery voltage. It will also help to align
multiple charge controllers in parallel, communicating via CAN bus.
2020-02-07 11:55:51 +01:00
Martin Jaeger 53ae6d4608 File headers shortened using SPDX-License-Identifier 2019-12-20 11:40:10 +01:00
Martin Jaeger 7412b11002 ADC filtering in separate function + unit-tests 2019-11-04 18:02:43 +01:00
Martin Jaeger 22f9138a15 LogData renamed to DeviceStatus / dev_stat
Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
2019-11-01 09:54:01 +01:00